scholarly journals Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.

Heart ◽  
1981 ◽  
Vol 45 (4) ◽  
pp. 365-368 ◽  
Author(s):  
M St John Sutton ◽  
R Roudaut ◽  
P Oldershaw ◽  
H Bricaud
Heart ◽  
1977 ◽  
Vol 39 (12) ◽  
pp. 1283-1291 ◽  
Author(s):  
M G St John Sutton ◽  
T A Traill ◽  
A S Ghafour ◽  
D J Brown ◽  
D G Gibson

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Fukui ◽  
P Sorajja ◽  
M Goessl ◽  
R Bae ◽  
B Sun ◽  
...  

Abstract Background Data on changes in left atrial (LA) and left ventricular (LV) volumes after transcatheter mitral valve replacement (TMVR) are limited. Purpose This study sought to describe the anatomical and functional changes in left-sided cardiac chambers by computed tomography angiography (CTA) from baseline to 1-month after TMVR with Tendyne prosthesis. Methods We analyzed patients who underwent TMVR with Tendyne prosthesis (Abbott Structural, Menlo Park, CA) between 2015 and 2018. Changes in LV end-diastolic volume (LVEDV), ejection fraction (LVEF), mass (LV mass), LA volume and global longitudinal strain (GLS) were assessed at baseline and at 1-month after TMVR with CTA. Specific Tendyne implant characteristics were identified and correlated with remodeling changes. Results A total of 36 patients (mean age 73±8 years, 78% men, 86% secondary MR) were studied. There were significant decreases in LVEDV (268±68 vs. 240±66ml, p<0.001), LVEF (38±10 vs. 32±11%, p<0.001), LV mass (126±37 vs. 117±32g, p<0.001), LA volume (181±74 vs. 174±70 ml, p=0.027) and GLS (−12.6±5.1 vs. −9.5±4.0%, p<0.001) from baseline to 1-month follow-up. Favorable LVEDV reverse-remodeling occurred in the majority (30 of 36 patients, or 83%). Closer proximity of the Tendyne apical pad to the true apex was predictive of favorable remodeling (pad distance: 25.0±7.7 vs. 33.5±8.8mm, p=0.02 for those with and without favorable remodeling). Conclusions TMVR with Tendyne results in favorable left-sided chamber remodeling in the majority of patients treated, as detected on CTA at 1-month after implantation. CTA identifies the favorable post-TMVR changes, which could be related to specific characteristics of the device implantation. Funding Acknowledgement Type of funding source: None


1994 ◽  
Vol 2 (2) ◽  
pp. 90-94
Author(s):  
Masaharu Shigenobu ◽  
Shunji Sano

This study compares mitral valve repair and mitral valve replacement with chordal preservation for chronic mitral regurgitation due to myxomatous degeneration with special reference to left ventricular function. Twenty-six patients underwent complete preoperative and 2 years later postoperative echocardiography study. Thirteen patients underwent mitral valve replacement associated with preservation of chordae tendineae and papillary muscles, and 13 patients had mitral valve repair. There were no statistically significant differences between the 2 groups for clinical findings, hemodynamic profiles, or left ventricular function compared prior to surgery. After correcting mitral regurgitation, increase in cardiac index was significant for the repair group. Left ventricular end-diastolic volume decreased in both groups. Left ventricular end-systolic volume significantly decreased in the repair group, but remained unchanged in the replacement group. Both ejection fraction and mean left ventricular circumferential fiber shortening velocity (mVcf) decreased in the replacement group, but significantly increased in the repair group 2 years after surgery. These findings suggest valve replacement with chordal preservation shows less improvement in ventricular systolic function late after surgery compared with mitral valve repair.


2014 ◽  
Vol 41 (2) ◽  
pp. 195-197 ◽  
Author(s):  
Myles E. Lee ◽  
Mallika Tamboli ◽  
Anthony W. Lee

One difficulty with external repair of left ventricular rupture after mitral valve replacement is collateral bleeding in friable myocardium adjacent to the rupture. The bleeding is caused by tension on the closing sutures, whether or not pledgets have been used. We report the case of a 69-year-old woman who underwent an uneventful mitral valve replacement. After cardiopulmonary bypass was terminated, brisk bleeding started from high in the posterior left ventricular wall, typical of a type III defect. We undertook external repair, placing a plug of Teflon felt into the cavity of the rupture and sandwiching it into place with pledgeted mattress and figure-of-8 sutures. The space occupied by the plug decreased the distance needed to obliterate the defect and thereby reduced the tension on the sutures necessary to achieve hemostasis. This simple technique enabled closure of the defect and avoided collateral tears that would have compromised an otherwise successful repair. Two years postoperatively, the patient had normal mitral valve function and no left ventricular aneurysm. In addition to reporting the patient's case, we review the types of left ventricular rupture that can occur during mitral valve replacement and discuss the various repair options.


Sign in / Sign up

Export Citation Format

Share Document