mitral valve repair
Recently Published Documents


TOTAL DOCUMENTS

3435
(FIVE YEARS 1076)

H-INDEX

74
(FIVE YEARS 11)

2022 ◽  
Vol 8 ◽  
Author(s):  
Nicole Lewandowski ◽  
Ehssan Berenjkoub ◽  
Eduard Gorr ◽  
Marc Horlitz ◽  
Peter Boekstegers ◽  
...  

Background: Infective endocarditis (IE) following mitral valve edge-to-edge repair is a rare complication with high mortality.Case summary: A 91-year-old male patient was admitted to intensive care unit with sepsis due to urinary tract infection after insertion of a urinary catheter by the outpatient urologist. Two weeks ago, the patient was discharged from hospital after successful transcatheter edge-to-edge mitral valve repair (TEER) using a PASCAL Ace device. The initially withdrawn blood revealed repeatedly Proteus mirabilis bacteremia as causal for the sepsis due to urinary tract infection. An antibiotic regime with Ampicillin/Sulbactam was initiated and discontinued after 7 days. During the clinical course the patient again developed fever and blood cultures again revealed P. mirabilis. In transesophageal echocardiography (TOE), IE of the PASCAL Ace device was confirmed by a vegetation accompanied by a mild to moderate mitral regurgitation. While the patient was stable at this time and deemed not suitable for cardiac surgery, the endocarditis team made a decision toward a prolonged 6-week antibiotic regime with an antibiotic combination of Ampicillin 2 g qds and Ciprofloxacin 750 mg td. Due to posterior leaflet perforation severe mitral regurgitation developed while PASCAL Ace vegetations were significantly reduced by the antibiotic therapy. Therefore, the patient underwent successful endoscopic mitral valve replacement. Another 4 weeks of antibiotic treatment with Ampicillin 2 g qds followed before the patient was discharged.Discussion:P. mirabilis is able to form biofilms, resulting in a high risk for endocarditis following transcatheter mitral valve repair especially when device endothelization is incomplete. Endoscopic mitral valve replacement could serve as a bailout strategy in refractory Clip-endocarditis.


Author(s):  
Annemarie Kirschfink ◽  
Mhd Nawar Alachkar ◽  
Mohammad Almalla ◽  
Julian Grebe ◽  
Felix Vogt ◽  
...  

AbstractTMVR using different clip sizes is a treatment option for selected patients with mitral regurgitation (MR). This study sought to identify predictors of successful transcatheter mitral valve repair (TMVR) by 3-dimensional (3D) echocardiography and to compare different effects of the larger XTR and the smaller NT/NTR devices. 3D transesophageal echocardiography was performed on 54 patients with secondary MR undergoing TMVR with one clip (55.6% NT/NTR, 44.4% XTR). All NT/NTR and 96% of XTR patients had MR reduction ≤ 2+. Despite more severe baseline MR (3D vena contracta area (VCA): 0.67 ± 0.34 cm2 vs. 0.43 ± 0.19 cm2, p = 0.004) and greater mitral valve area (MVA) (6.8 ± 2.1 cm2 vs. 5.1 ± 1.6 cm2, p = 0.001) in the XTR group, MR severity after TMVR was not different between XTR and NT/NTR patients (3D VCA: 0.19 ± 0.14 vs. 0.17 ± 0.10, p = 0.51). Baseline 3D VCA > 0.45 cm2 in NT/NTR (AUC = 0.802, 95% CI 0.602 to 1.000) and 3D VCA > 0.54 cm2 in XTR devices (AUC = 0.868, 95% CI 0.719 to 1.000) were associated with ineffective MR reduction defined as residual VCA ≤ 0.2 cm2. Baseline MVA ≤ 4.2 cm2 in NT/NTR (AUC = 0.920, 95% CI 0.809 to 1.000) and MVA ≤ 6.0 cm2 in XTR devices (AUC = 0.865, 95% CI 0.664 to 1.000) were associated with postprocedural transmitral pressure gradient (TMPG) ≥ 5 mmHg. TMVR using the XTR device resulted in an equally effective reduction of MR despite of a greater baseline MR. Distinct cut-off values of baseline 3D VCA and MVA for prediction of successful MR reduction and postprocedural increase of TMPG were identified for the different devices.


Author(s):  
Chi-Hion Pedro Li ◽  
Lluís Asmarats ◽  
M. Luz Maestre ◽  
Estefanía Fernández ◽  
Antonio Serra, and ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document