Performance of point of care assays for hepatitis B and C viruses in chronic kidney disease patients

2018 ◽  
Vol 71 (10) ◽  
pp. 879-884 ◽  
Author(s):  
Jakeline Ribeiro Barbosa ◽  
Vanessa Faria Cortes ◽  
Moyra Machado Portilho ◽  
Juliana Custódio Miguel ◽  
Vanessa Alves Marques ◽  
...  

AimsPoint of care testing (POCT) has been used for hepatitis B and C diagnosis in general population, but little is known about the influence of clinical conditions in the accuracy of these assays. This study aims to evaluate the performance of POCTs for detection of hepatitis B virus surface antigen (HBsAg) and antibodies to Hepatitis C Virus (anti-HCV) in Chronic Kidney Disease (CKD) patients.MethodsA total of 286 subjects were included in this study. HBsAg and anti-HCV were detected using commercial EIAs and four POCTs: HBsAg (WAMA Imuno-Rápido HBsAg and VIKIA HBsAg) and anti-HCV (DOLES HCV teste rápido and WAMA Imuno-Rápido anti-HCV) in serum and whole blood.ResultsUsing EIA, HBsAg and anti-HCV prevalence was 4.5% and 16.1% in CKD patients. HBsAg and anti-HCV POCTs had sensitivities from 92.3% to 100% and 84.8% to 89.1% while specificities were 99.3% to 100% and 99.2% to 99.6%, respectively. POCT using serum samples performed well compared with whole blood samples and true positive samples of POCTs had high optical density to cut-off (OD/CO) values compared with EIA.ConclusionsThis study demonstrates good performance of HBsAg and anti-HCV POCTs in CKD patients, especially in serum samples indicating low interference of this disease in the performance of these assays. POCTs could be an important tool for HBV and HCV screening in high-risk populations.

2020 ◽  
Vol 7 ◽  
pp. 205435812097071
Author(s):  
Melissa Nataatmadja ◽  
Angela W. S. Fung ◽  
Beryl Jacobson ◽  
Jack Ferera ◽  
Eva Bernstein ◽  
...  

Background: The StatSensor is a point-of-care device which measures creatinine in capillary whole blood. Previous studies reported an underestimation of the creatinine measurements at high creatinine concentrations and were performed in the prestandardization era for creatinine. Objective: This accuracy-based study evaluates the use of this device in kidney-transplanted patients and those with chronic kidney disease (CKD). Design: Cross-sectional diagnostic accuracy study. Setting: Nephrology outpatient clinic in an urban tertiary center. Participants: Adults with CKD or a functioning kidney transplant. Measurements: Duplicate StatSensor creatinine measurements were performed on capillary whole blood samples collected by direct fingerstick and SAFE-T-FILL collection device. Results were compared with simultaneous venous blood sampling for serum and plasma creatinine measured by an enzymatic method on the Roche Integra 400 mainframe analyzer with traceability to the ID-GC-MS (isotope dilution gas chromatography mass spectrometry) reference method. Methods: Deming regression, Pearson correlation coefficient, and Bland-Altman analysis were used to assess accuracy and comparability between capillary whole blood measured by StatSensor and plasma creatinine measured by routine analyzer with traceability to the reference method. Estimated glomerular filtration (eGFR) rates were calculated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation and concordance with Kidney Disease Improving Global Outcomes (KDIGO) CKD stage classification was evaluated. Results: There were 60 participants (mean age = 61.9 ± 15.0 years, 55% men, 33% transplant, mean plasma creatinine = 137 ± 59 µmol/L). Bland-Altman analysis indicated a positive mean bias of 12.7 µmol/L between StatSensor fingerstick creatinine measurement and plasma creatinine. Comparison of eGFR (CKD-EPI) calculated from the StatSensor fingerstick creatinine versus plasma creatinine showed misclassification across all KDIGO CKD stages. Postanalytical correction of the bias did not improve misclassifications. The use of mean of duplicate StatSensor creatinine results did not improve performance compared with the use of singlet results. Limitations: Single center, limited participant numbers. Conclusions: The results of our study suggest that the limiting characteristics of the StatSensor device are not only bias, but also imprecision. The level of imprecision observed may influence clinical decision-making and limit the usefulness of StatSensor as a CKD screening tool. If choosing to utilize it for either screening for or monitoring CKD, it is essential that clinicians understand the limitations of point-of-care devices and apply this knowledge to test interpretation.


2012 ◽  
Vol 59 (13) ◽  
pp. E2096 ◽  
Author(s):  
Usman Baber ◽  
M. Urooj Zafar ◽  
jaime uribarri ◽  
Barbara Murphy ◽  
Avi Khan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document