scholarly journals LB-009 Retreatment of residual and recurrent aneurysms following embolization with the woven endobridge (WEB) device: multicenter case series

Author(s):  
V Srinivasan ◽  
A Dmytriw ◽  
R Regenhardt ◽  
J Vicenty-Padilla ◽  
M Aziz-Sultan ◽  
...  
2021 ◽  
pp. neurintsurg-2021-017405
Author(s):  
Guilherme Aguiar ◽  
Jildaz Caroff ◽  
Cristian Mihalea ◽  
Jonathan Cortese ◽  
Jean-Baptiste Girot ◽  
...  

BackgroundWoven EndoBridge (WEB) device treatment of wide-neck bifurcation aneurysms has proved to be safe and effective, but the use of these devices in sidewall aneurysms has been reported only in a small number of case series.ObjectiveTo report our results in a cohort of consecutive patients in whom a WEB device was used as first-line treatment for posterior communicating artery (PComA) aneurysms.MethodsWe conducted a retrospective analysis of a prospectively maintained database of PComA aneurysms treated with a WEB device in our institution from June 1, 2012 to November 15, 2020. Clinical and radiological findings were evaluated at immediate and last follow-up.ResultsA total of 219 aneurysms were treated with a WEB device, including 15 PComA aneurysms in 15 patients, 10 of which were ruptured. Aneurysms were wide necked, with a mean aspect ratio of 1.6 (range 0.7–3.0) and a mean neck size of 4.2 mm (range 2.6–7.4 mm). No intraoperative rupture occurred and only one thromboembolic event was noted. Among the group with at least a 3-month digital subtraction angiography (DSA) follow-up, complete and adequate occlusion were obtained in 54% and 72%, respectively (average follow-up 13 months). Re-treatment was needed for two initially ruptured aneurysms. No procedure-related morbidity or mortality was reported.ConclusionThis series suggests the high safety profile of WEB devices even when used in off-label indications. Treatment with these devices seems to be a valuable strategy for ruptured wide-neck PComA aneurysms, avoiding the need for antiplatelet medication. However, occlusion rates should be investigated in further larger studies.


2020 ◽  
pp. 159101992097288
Author(s):  
Tapan Mehta ◽  
Ameer Hassan ◽  
Kamran Masood ◽  
Wondwossen Tekle ◽  
Andrew Grande ◽  
...  

Background The use of compliant dual lumen balloon microcatheters (CDLB) for the endovascular treatment of vascular malformations, wide neck aneurysms, and intracranial angioplasty (for vasospasm) is well documented. Navigation of 4 mm or larger CDLB within tortuous and small distal intracranial vessels can be challenging. Recently, the lower profile Scepter Mini balloon microcatheter (SMB) has been approved for use, with potential for improved intracranial navigation. Objective Discuss operative experience of Scepter Mini (Microvention, Aliso Viejo, CA). Methods We describe our initial experience with the SMB in a series of nine patients. Results The balloon microcatheter was used for delivery of liquid embolic in six patients (Case 1, 2, 6–9), adjunct support for delivery or positioning of the Woven Endobridge (WEB) device in two (Case 3,4), and gentle post-deployment repositioning of a WEB device in the last one (Case 5). We were able to successfully navigate the SMB over a 0.008 “micro wire to the target lesion in all the patients. We experienced initial difficulty with injecting liquid embolic in Case 2. We postulate that the SMB was in a tortuous segment of a dural vessel in this patient, and that it kinked on inflation with occlusion of the liquid embolic delivery lumen; this was overcome with slightly proximal repositioning and reinflation of the SMB. Conclusion Our initial experience shows that the SMB has potential to be useful in endovascular neurosurgical procedures requiring balloon assistance within smaller diameter blood vessels.


2020 ◽  
pp. 159101992097221
Author(s):  
Colin Son ◽  
Samon Tavakoli-Sabour

Background Transradial access is an increasingly utilized route for neurointerventions with benefits of lower rates of access site complications, earlier patient mobilization and increased patient satisfaction over transfemoral interventions. There is limited data on deployment of the Woven EndoBridge (WEB) via transradial access. We report a case series of consecutive patients undergoing cerebral aneurysm embolization with the WEB device via transradial biaxial access. Methods A database of neuroendovascular procedures was queried for consecutive aneurysm embolization procedures involving the WEB device and intended via the transradial approach between August 2019 and July 2020. Patient demographics, radiological aneurysm characteristics and procedure details were recorded and statistically evaluated. Google Scholar and Pubmed were searched for previous reports of transradial WEB embolization. Results Ten aneurysms were treated in ten patients. All aneurysms were treated with successful WEB deployment. Nine of the ten aneurysms were successfully treated via transradial biaxial access. One aneurysm required conversion to transfemoral access. There were no clinical complications and no morbidity or mortality. Conclusions Transradial embolization of cerebral aneurysms with the WEB device is safe and feasible with low rates of access failure or complications.


2021 ◽  
Author(s):  
Daniel M Heiferman ◽  
Jeremy C Peterson ◽  
Kendrick D Johnson ◽  
Vincent N Nguyen ◽  
David Dornbos ◽  
...  

Abstract The Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, California) is an intrasaccular flow disruptor used for the treatment of both unruptured and ruptured intracranial aneurysms. WEB has been shown to have 54% complete and 85% adequate aneurysm occlusion rates at 1-yr follow-up.1 Residual and recurrent ruptured aneurysms have been shown to have a higher risk of re-rupture than completely occluded aneurysms.2 With increased utilization of WEB in the United States, optimizing treatment strategies of residual aneurysms previously treated with the WEB device is essential, including surgical clipping.3,4 Here, we present an operative video demonstrating the surgical clip occlusion of previously ruptured middle cerebral artery and anterior communicating artery aneurysms that had been treated with the WEB device and had sizable recurrence on follow-up angiography. Informed consent was obtained from both patients. Lessons learned include the following: (1) the WEB device is highly compressible, unlike coils; (2) proximal WEB marker may interfere with clip closure; (3) no evidence of WEB extrusion into the subarachnoid space; (4) no more scarring than expected in ruptured cases; and (5) clipping is a feasible option for treating WEB recurrent or residual aneurysms.


2016 ◽  
Vol 22 (3) ◽  
pp. 299-303 ◽  
Author(s):  
Yong-Hong Ding ◽  
Daying Dai ◽  
Dana Schroeder ◽  
Ramanathan Kadirvel ◽  
David F Kallmes

The dual-layer Woven EndoBridge (WEB) device (WEB II) is designed to improve the performance of the first-generation WEB device. This study was performed to evaluate the acute and chronic performance of WEB II for aneurysm occlusion in an elastase-induced aneurysm model in rabbits. We implanted WEB II devices in 36 elastase-induced aneurysms and followed up for one, three, six, and 12 months. Degree of aneurysm occlusion at follow-up was graded on the Web Occlusion Scale (WOS): Grade A, complete aneurysm occlusion; Grade B, complete occlusion with recess filling; Grade C, residual neck filling; and Grade D, residual aneurysm filling. Hematoxylin and eosin staining was performed for histological assessment of aneurysm healing. Grades A, B, C, and D aneurysm occlusion at one-month follow-up were noted in three (17%), three (17%), eight (44%), and four (22%) of 18 cases, respectively. At the three-month time point Grades A, B, C, and D were shown in two (33%), two (33%), one (17%), and one (17%) aneurysms. Six months after treatment, one (17%), two (33%), two (33%), and one (17%) cases demonstrated Grades A, B, C, and D occlusion. At the 12-month time point, Grades B, C, and D were shown in three (50%), two (33%), and one (17%) aneurysms. Histologic evaluation showed progressive thrombus organization within aneurysm lumen from one to 12 months. These results indicated that the WEB II device can achieve high rates of aneurysm occlusion over time in experimental aneurysms.


2018 ◽  
Vol 11 (4) ◽  
pp. 386-389 ◽  
Author(s):  
Cristian Mihalea ◽  
Simon Escalard ◽  
Jildaz Caroff ◽  
Léon Ikka ◽  
Aymeric Rouchaud ◽  
...  

BackgroundWoven EndoBridge (WEB) deployment remains challenging in aneurysms with a complex shape or orientation.ObjectiveTo show that embolization of wide-neck bifurcation aneurysms using the WEB device balloon remodeling-assisted technique is a feasible and elegant endovascular solution compared with other techniques, such as balloon remodeling or stent-assisted coiling.Materials and methods10 cases (10 aneurysms in 9 patients) of balloon remodeling-assisted WEB treatment of unruptured complex bifurcation aneurysms were treated in our institution and retrospectively analyzed. Details of clinical presentations, technical details, perioperative and postoperative complications, and outcomes were collected. Immediate and long-term angiographic results were also evaluated.ResultsAneurysms included six middle cerebral artery aneurysms, one anterior communicating artery aneurysm, one posterior communicating artery aneurysm, one basilar artery aneurysm, and one T-shaped carotid aneurysm. Mean dome width was 6.55 mm, mean neck size 4.5 mm, mean height 4.79 mm, and mean dome-to-neck ratio was 1:1.46. Treatment was performed exclusively with the balloon remodeling-assisted WEB technique in all cases. The device was successfully deployed in every case. Periprocedural thromboembolic or hemorrhagic events did not occur. The modified Rankin Scale score at discharge was 0 for all patients. At mid-term or long-term angiographic follow-up, adequate occlusion was observed in 7 aneurysms from 8 controlled cases (87.5%), and one patient (2 aneurysms) did not have angiographic follow-up.ConclusionThe balloon remodeling-assisted WEB technique seems to be a safe and effective solution for endovascular treatment of unruptured wide-neck bifurcation aneurysms with specific complex anatomy. However, further studies are needed to evaluate the rate of complications and long-term efficacy.


Neurosurgery ◽  
2020 ◽  
Vol 87 (1) ◽  
pp. E16-E22 ◽  
Author(s):  
Fadi Al Saiegh ◽  
David Hasan ◽  
Nikolaos Mouchtouris ◽  
Mario Zanaty ◽  
Ahmad Sweid ◽  
...  

Abstract BACKGROUND Coil embolization of ruptured bifurcation aneurysms is challenging and often necessitates adjunctive stenting, which requires antiplatelet therapy in the setting of subarachnoid hemorrhage (SAH). The Woven EndoBridge (WEB; Terumo) device is an alternative self-expanding 3D mesh that does not require antiplatelet agents. However, its use has been mostly reserved for unruptured aneurysms. OBJECTIVE To assess the safety and feasibility of ruptured aneurysm treatment with the WEB. METHODS Retrospective analysis of 9 SAH patients with 11 aneurysms that were treated with the WEB device at 2 institutions after FDA approval. RESULTS Hunt and Hess grades were III and IV in 4 (44%) each and V in 1 (11%). All patients were treated within 24 h of hospitalization, and a single WEB was used in all but one aneurysm. Aneurysms treated were 3 basilar tip, 2 anterior communicating artery, 2 posterior inferior cerebellarartery, 1 middle cerebral artery, 1 carotid-ophthalmic artery, 1 posterior communicating artery, and 1 vertebrobasilar junction. Mean aneurysm height and width were 6.2 ± 2.2 mm (range: 3-10) and 5.6 ± 3.0 mm (range: 3.3-14), respectively. Mean dome-to-neck ratio was 1.7 ± 0.8 (range: 1.0-3.8). There was one intraoperative rupture that occurred because of device dislodgement and was managed with embolization. There were no treatment-related mortalities and no re-rupture after securement of the aneurysms with the WEB. CONCLUSION Our preliminary experience indicates that the WEB device can be used safely for ruptured aneurysms of various sizes in the anterior and posterior circulation. Larger series with long-term follow-up are necessary to confirm our findings.


2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


Sign in / Sign up

Export Citation Format

Share Document