web device
Recently Published Documents


TOTAL DOCUMENTS

112
(FIVE YEARS 67)

H-INDEX

16
(FIVE YEARS 5)

2021 ◽  
pp. 159101992110576
Author(s):  
Mohamed Abdelrady ◽  
Cyril Dargazanli ◽  
Imad Derraz ◽  
Federico Cagnazzo ◽  
Vincent Costalat

Objective Intra-procedural WEB device migration is a scarcely reported complication that necessitates prompt intervention. Case Presentation Endovascular treatment of two broad necked flow-related aneurysms was planned aided by WEB-SL (Woven EndoBridge-single layer) devices in a 71-year-old female with known left temporal arteriovenous malformation. Inadvertent distal migration occurred while performing a control angiogram with an automated iodine injector. Immediate retrieval was successfully performed using a Solitaire stent-retriever. Conclusion To our knowledge, we report for the first time the successful retrieval of a distally migrated WEB using a stent-retriever device.


Author(s):  
Laurent Pierot

Intrasaccular flow disruption is an innovative approach for the endovascular treatment of intracranial aneurysms. As of now, only one device is currently available worldwide: the Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, CA, USA). After 10 years of clinical use and careful clinical evaluation of the WEB device by multiple prospective, multicenter studies, this article is summarizing the current knowledge regarding this endovascular technique; indications, modalities, safety and efficacy of the WEB procedure are described.


Author(s):  
Krishna Amuluru ◽  
Fawaz Al-Mufti ◽  
Daniel H. Sahlein ◽  
John Scott ◽  
Andrew Denardo

The Woven EndoBridge (WEB) is an intrasaccular flow-disrupting device for the treatment of wide-necked saccular cerebral aneurysms. As with any neuroendovascular device, complications in the form of malpositioning and migration must be managed quickly and safely. Few studies have reported complication management techniques in instances of dislocated or migrated WEB devices. We retrospectively describe a case of a malpositioned WEB device that was successfully adjusted with the use of a gooseneck snare. Multiple other intra-procedural bailout strategies for management of WEB malposition and migration were considered, and are herein discussed. Operators should be aware of the causes of WEB malposition and a variety of bailout strategies.


2021 ◽  
pp. 1-7
Author(s):  
Nikolaos Mouchtouris ◽  
David Hasan ◽  
Edgar A. Samaniego ◽  
Fadi Al Saiegh ◽  
Ahmad Sweid ◽  
...  

OBJECTIVE Wide-neck bifurcation cerebral aneurysms have historically required either clip ligation or stent- or balloon-assisted coil embolization. This predicament led to the development of the Woven EndoBridge (WEB) aneurysm embolization system, a self-expanding mesh device that achieves intrasaccular flow disruption and does not require antithrombotic medications. The authors report their operative experience and 6-month follow-up occlusion outcomes with the first 115 aneurysms they treated via WEB embolization. METHODS The authors reviewed the first 115 cerebral aneurysms they treated by WEB embolization after FDA approval of the WEB embolization device (from February 2019 to January 2021). Data were collected on patient demographics and clinical presentation, aneurysm characteristics, procedural details, postembolization angiographic contrast stasis, and functional outcomes. RESULTS A total of 110 patients and 115 aneurysms were included in our study (34 ruptured and 81 unruptured aneurysms). WEB embolization was successful in 106 (92.2%) aneurysms, with a complication occurring in 6 (5.5%) patients. Contrast clearance was seen in the arterial phase in 14 (12.2%) aneurysms, in the capillary phase in 16 (13.9%), in the venous phase in 63 (54.8%), and no contrast was seen in 13 (11.3%) of the aneurysms studied. Follow-up angiography was performed on 60 (52.6%) of the aneurysms, with complete occlusion in 38 (63.3%), neck remnant in 14 (23.3%), and aneurysmal remnant in 8 (13.3%). Six (5.5%) patients required re-treatment for persistent aneurysmal residual on follow-up angiography. CONCLUSIONS The WEB device has been successfully used for the treatment of both unruptured and ruptured wide-neck bifurcation aneurysms by achieving intrasaccular flow diversion. Here, the authors have shared their experience with its unique technical considerations and device size selection, as well as critically reviewed complications and aneurysm occlusion rates.


2021 ◽  
pp. neurintsurg-2021-017416
Author(s):  
Laurent Spelle ◽  
Denis Herbreteau ◽  
Jildaz Caroff ◽  
Xavier Barreau ◽  
Jean-Christophe Ferré ◽  
...  

BackgroundThe primary goal of the CLARYS study is to assess the protection against rebleeding when treating ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) device.MethodsThe CLARYS study is a prospective, multicenter study conducted in 13 European centers. Patients with ruptured bifurcation aneurysms were consecutively included between February 2016 and September 2017. The primary endpoint was defined as the rebleeding rate of the target aneurysm treated with the WEB within 30 days postprocedure. Secondary endpoints included periprocedural and postprocedural adverse events, total procedure and fluoroscopy times, and modified Rankin Scale score at 1 month and 1 year.ResultsSixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. A WEB device was successfully implanted in 93.3%. The rebleeding rate at 1 month and 1 year was 0%. The mean fluoroscopy time was 27.0 min. Twenty-three periprocedural complications were observed in 18 patients and resolved without sequelae in 16 patients. Two of these complications were attributed to the procedure and/or the use of the WEB, leading to a procedure/device-related intraoperative complication rate of 3.3%. Overall mortality at 1 month and 1 year was 1.7% and 3.8%, respectively and overall morbidity at 1 month and 1 year was 15% and 9.6%, respectively. WEB-related 1-month and 1-year morbidity and mortality was 0%.ConclusionsThe interim results of CLARYS show that the endovascular treatment of ruptured bifurcation aneurysms with the WEB is safe and effective and, in particular, provides effective protection against rebleeding. It may induce profound change in the endovascular management of ruptured bifurcation aneurysms.


Author(s):  
Fadi Al Saiegh ◽  
Lohit Velagapudi ◽  
Omaditya Khanna ◽  
Ahmad Sweid ◽  
Nikolaos Mouchtouris ◽  
...  

Author(s):  
V Srinivasan ◽  
A Dmytriw ◽  
R Regenhardt ◽  
J Vicenty-Padilla ◽  
M Aziz-Sultan ◽  
...  

2021 ◽  
pp. neurintsurg-2021-017613
Author(s):  
Andre Monteiro ◽  
Audrey L Lazar ◽  
Muhammad Waqas ◽  
Hamid H Rai ◽  
Ammad A Baig ◽  
...  

The Woven EndoBridge (WEB) device is a barrel-shaped nitinol mesh deployed within the aneurysmal sac. The absence of metallic mesh in the aneurysm’s parent vessel lumen obviates the need for potent antiplatelet therapy, making this device appealing for acutely ruptured aneurysms not amenable to clipping or coiling. To assess the literature regarding WEB treatment of these aneurysms, we performed a comprehensive systematic search of PubMed, MEDLINE, and EMBASE databases following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Keywords were combined with Boolean operators to increase search sensitivity and specificity (‘woven endobridge device’ AND ‘ruptured’). Nine studies comprising 377 acutely ruptured aneurysms were included. Overall, 82.7% were wide-necked, 85.9% were located in the anterior circulation, and 26.9% of patients presented with poor subarachnoid hemorrhage grade. Intraprocedure and postprocedure complications occurred in 8.4% (95% CI 3.6% to 13.3%) and 1% (95% CI 0% to 2%), respectively. The post-treatment rebleeding rate was 0%. Rates of adequate occlusion (complete occlusion to neck remnant) and retreatment at last follow-up were 84.8% (95% CI 73% to 96.6%) and 4.5% (95% CI 2.2% to 6.8%), respectively. The favorable outcome rate (modified Rankin Scale score 0–2) was 62.2% (95% CI 53% to 71.4%); mortality was 13.6% (95% CI 9.7% to 17.6%). WEB treatment of acutely ruptured aneurysms results in high adequate occlusion rates, low perioperative complication rates, no rebleeding, and low recurrence requiring retreatment. This device is promising for acutely ruptured aneurysms not amenable to clipping or coiling, considering the lower need for antiplatelet regimens during the procedure or follow-up.


Sign in / Sign up

Export Citation Format

Share Document