DORSAL PLATING FOR COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS

Hand Surgery ◽  
2004 ◽  
Vol 09 (02) ◽  
pp. 181-190 ◽  
Author(s):  
D. Osada ◽  
K. Tamai ◽  
A. Iwamoto ◽  
S. Fujita ◽  
K. Saotome

Forty-one dorsally displaced intra-articular fractures of the distal radius were treated by open reduction and internal fixation with the dorsal Symmetry® plates. The average age at the time of the injury was 49 years. An average follow-up period was 15 months. The final radial length averaged 11 mm, radial inclination 23°, volar tilt 7°, ulnar variance 1.5 mm, and articular incongruity 0.3 mm. According to the Gartland and Werly scales, 36 fractures were excellent and five were good. However, ulnar variance increased more than 3 mm during follow-up in eight patients, and volar tilt increased more than 5° during follow-up in ten patients. Use of dorsal Symmetry® plate is effective for unstable comminuted intra-articular distal radius fractures, but severely comminuted fractures may possibly undergo re-displacement post-operatively.

2017 ◽  
Vol 22 (04) ◽  
pp. 423-428 ◽  
Author(s):  
Yoshihiro Abe ◽  
Masahiro Suzuki ◽  
Hiromasa Wakita

Background: To assess the surgical results of distal radius fractures with the involvement of a volar rim fragment using the DePuy-Synthes 2.0 mm and 2.4 mm locking plates.Methods: Subjects were six women and one man of average age 57 years (range, 31–83 y) and a mean follow-up period of 9 months (range, 5–19 mo) with AO B3 (volar shearing) distal radius fractures. Time of the procedure, physical examination of wrist range of motion, grip strength compared with the contralateral healthy wrist, and radiographic evaluation (volar tilt, radial inclination, and ulnar variance) were evaluated. The Visual Analog Scale (VAS: 0 points represents no pain, 100 points represents the worst pain possible) and the Quick Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH, 0 = no disability, 100 = extreme disability) were completed by patients at the final follow-up.Results: The average time of the procedure was 74 min. There were no perioperative complications. Average radiographic measures were: volar tilt, 8°; radial inclination, 23°, and ulnar variance, 0 mm. Wrist range of motion averaged 63° in wrist extension (range, 55–80°) and 55° in wrist flexion (range, 45–65°). Grip strength averaged 81% of the contralateral side at final evaluation (range, 67–100%). The mean QuickDASH score was 3.0 points (range, 0–9.1 points) and the mean VAS for pain was 9.3 at final follow-up.Conclusions: Open reduction internal fixation with the DePuy-Synthes 2.0 mm and 2.4 mm locking plates is an effective means of fixing a distal radius fracture that includes a volar rim fragment without interfering with flexor tendon gliding.


2012 ◽  
Vol 37 (8) ◽  
pp. 765-771 ◽  
Author(s):  
A. S. Gavaskar ◽  
S. Muthukumar ◽  
N. Chowdary

The goal was to evaluate the efficacy of 2.4 mm column-specific plating for intra-articular distal radius fractures. In total, 105 patients with AO type C distal radius fractures were operated on using the locking distal radius system, Synthes. Follow-up assessments including clinical (wrist and forearm range of motion, grip strength), radiological (articular step, radial length and inclination, volar tilt, and ulnar variance), and functional scores (Disabilities of the Arm, Shoulder, and Hand; Patient Rated Wrist Evaluation) were made at regular intervals until 1 year. Union was obtained in all patients. Articular surface was anatomically reconstructed in 74 patients (70.5%). Clinical and functional evaluation showed significant continuous improvements over the first year. C1 fractures had a better chance of anatomical reduction compared with C2 and C3 fractures. Fracture type, quality of reduction, and presence of degenerative changes did not show a significant effect on functional outcome scores. Column-specific fixation of the distal radius can achieve satisfactory results in complex intra-articular fractures.


2003 ◽  
Vol 28 (6) ◽  
pp. 568-570 ◽  
Author(s):  
S. GANGOPADHYAY ◽  
G. PACKER

A retrospective review of 24 patients with dorsal incisions for open reduction and internal fixation of Frykman VII/VIII distal radius fractures using a dorsal plate was performed. Half of them had a longitudinal incision while the other half had a T-shaped incision. No difference in the healing properties or wound morbidity could be demonstrated between the two groups. However, the T incision provided improved exposure of the distal radius and patient satisfaction with its cosmetic result was superior. The horizontal limb was well camouflaged within the transverse skin crease on the dorsal aspect of the wrist. The vertical limb did not extend into the dorsum of the hand and could, therefore, be hidden by appropriate clothing.


2019 ◽  
Vol 101 (3) ◽  
pp. 203-207
Author(s):  
S Hassan ◽  
R Shafafy ◽  
A Mohan ◽  
P Magnussen

Introduction Isolated ulnar shortening osteotomies can be used to treat ulnocarpal abutment secondary to radial shortening following distal radius fractures. Given the increase of fragility distal radius fractures awareness of treating the sequelae of distal radius fractures is important. We present the largest reported case series in the UK of ulnar shortening osteotomies for this indication. Materials and methods Twenty patients with previous distal radial fractures were included, who presented with wrist pain and radiologically evident positive ulnar variance secondary to malunion of the distal radius with no significant intercalated instability. Patients were treated with a short oblique ulnar shortening osteotomy, using a Stanley jig and small AO compression plate system. Pre- and postoperative radiographical measurements of inclination, dorsal/volar angulation and ulnar variance were made. Patients were scored pre- and postoperatively using the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) and Patient-Rated Wrist Evaluation scores by two orthopaedic surgeons. Mean follow-up was 24 months after surgery. Results Radiographical analysis revealed a change in the ulnar variance with an average reduction of 5.74 mm. Mean preoperative scores were 61.1 (range 25–95.5) for QuickDASH and 70.4 (range 33–92) for Patient-Rated Wrist Evaluation. At the latest follow-up, mean postoperative QuickDASH scores were 10.6 (range 0–43.2) and 17.2 (range 0–44) for Patient-Rated Wrist Evaluation. Differences in scores after surgery for both QuickDASH and Patient-Rated Wrist Evaluation were statistically significant (P < 0.01). Conclusions The ulnar shortening osteotomy is a relatively simple procedure compared with corrective radial osteotomy, with a lower complication profile. In our series, patients showed significant improvement in pain and function by correcting the ulnar variance thus preventing ulna–carpal impaction.


Hand Surgery ◽  
2014 ◽  
Vol 19 (03) ◽  
pp. 357-362 ◽  
Author(s):  
Chul-Hyun Cho ◽  
Si-Wook Lee ◽  
Gu-Hee Jung

The purpose of this study was to compare the outcomes of volar plating using two different implants for distal radius fractures. Fifty-two patients with AO type C fractures were placed in either of two groups: the AO LDRS group (26 patients) or the Acu-Loc group (26 patients). Radiological parameters including radial length, radial inclination, volar tilt, and intra-articular step-off were significantly improved after surgery. The mean Mayo Wrist Performance Score was 84.6 in the AO LDRS group and 81.1 in the Acu-Loc group. The mean Subjective Wrist Value was 86.7% in the AO LDRS group and 86.3% in the Acu-Loc group. There were no significant differences between the two groups with respect to both radiological and clinical outcomes at the final follow-up evaluation. Volar fixed-angle plating for unstable distal radius fractures had satisfactory radiological and clinical outcomes. The difference of implant design did not influence overall final outcomes.


Hand Surgery ◽  
2003 ◽  
Vol 08 (01) ◽  
pp. 7-15 ◽  
Author(s):  
H. C. Lee ◽  
Y. S. Wong ◽  
B. K. Chan ◽  
C. O. Low

This study is to assess the effectiveness and outcome of the AO titanium volar distal radius plate (Synthes) in the treatment of peri-articular volar rim fractures of the distal radius. It was conducted on 22 patients with distal radius fractures who underwent open reduction, internal fixation using the AO titanium volar distal radius plate between July 1998 and December 1999 at the Changi General Hospital. The radiographs of the patients were analysed upon fracture union and assessment of wrist function was done using Gartland and Werley criteria. There were four extra-articular AO Type A2(1) and A3(3): the remaining 18 intra-articular fractures consisted of AO B3(2), AO C1(11), AO C2(2) and AO C3(3). The average follow-up period was 12.6 months (range 7–23). Radiological review showed bone healing in 21 patients (95.5%) and good articular congruity for all intra-articular fractures with less than 2 mm step-off. Three patients defaulted follow-up. Complications were few with one wound infection, one tendon rupture and three neuropraxia of the superficial radial nerve. Wrist function was excellent in three patients, good in 12 and fair in four. The AO titanium plate with its distal buttressing ability is an effective treatment modality in patients with distal radius fractures involving the peri-articular volar rim.


1970 ◽  
Vol 7 (4) ◽  
pp. 369-373 ◽  
Author(s):  
RL Pradhan ◽  
S Lakhey ◽  
BK Pandey ◽  
RR Manandhar ◽  
KP Rijal ◽  
...  

Background: Distal radius fractures are a common injury and without proper treatment leads to high functional impairment and frequent complications. Objective: The aim of this study was to see the functional outcome in patients with comminuted distal radius fractures treated with combined external fixation and open reduction with volar plating. Materials and methods: All comminuted distal radius fractures classified as type C in AO/OTA classification were enrolled for the study from 2005 till 2008. The clinical scoring chart modified by Cooney was used to evaluate the functional outcome. Results: There were twenty-two patients with the average age of 42.18 years (range 19-60) with 15 male and 7 females. The follow-up period was from 14 to 46 months. Accordingly, there were 11 (50%) excellent, 7 (31%) good, 2 (9%) fair and 2 (9%) poor results. There were very few complications in our series. In three patients additional K-wire supplementation was necessary along with external and open internal fixation. Conclusions: Comminuted intra-articular fractures of distal radius should be treated by open reduction and combined internal and external fixation to achieve a high rate of patient satisfaction and satisfactory functional outcome. Key words: distal radius fractures; volar plating; external fixationDOI: 10.3126/kumj.v7i4.2756 Kathmandu University Medical Journal (2009) Vol.7, No.4 Issue 28, 369-373


Hand Surgery ◽  
2011 ◽  
Vol 16 (01) ◽  
pp. 29-37 ◽  
Author(s):  
Akira Goto ◽  
Tsuyoshi Murase ◽  
Kunihiro Oka ◽  
Hideki Yoshikawa

Treatment of distal radius fractures with a volar fixed angle plate achieves sufficient stabilisation and permits early physical exercise. However, secondary displacement after surgery sometimes occurs in elderly patients with a metaphyseal comminution and/or cases in which the subchondral support pegs were not placed immediately below the subchondral zone.We treated elderly patients suffering from distal radius fractures with metaphyseal comminution, using both volar fixed angle plate with or without augmentation with a hydroxyapatite bone graft substitute to investigate the benefit of augmentation for maintaining a fracture reduction. We evaluated the differences among radiographic parameters including palmar tilt, radial inclination, and ulnar variance on immediate postoperative and final follow-up radiographs to analyse the maintenance of the initial reduction.There were no significant differences between the two groups in terms of palmar tilt (P = 0.80) and radial inclination (P = 0.17); however, ulnar variance increased significantly in the group treated with a volar fixed angle plate without augmentation (P < 0.05).It might be useful to use a combination technique of a locking plate system and the hydroxyapatite bone graft substitute as augmentation to treat distal radius comminuted fractures in elderly patients.


2008 ◽  
Vol 33 (3) ◽  
pp. 305-310 ◽  
Author(s):  
A. BINI ◽  
M. F. SURACE ◽  
G. PILATO

Twenty-two patients underwent surgery for 23 complex articular fractures of the distal radius of C.3 type, according to the AO classification. The surgical treatment consisted, in all cases, of a closed, or limited-open, reduction and external fixation. The functional and radiographic results were analysed at a mean follow-up of 40 months. This retrospective study confirms that satisfactory functional results where obtained in 12 out of the 15 wrists where all the intra and extra-articular parameters of the Fernandez’ criteria where respected. For those wrists where keeping with Fernandez’ criteria for intra-articular parameters and ulnar variance was not possible, four of eight had satisfactory results. As far as the acceptability criteria for radial inclination and dorsal tilt are concerned, the functional results seem to suggest that a little wider tolerance than proposed in the literature could be accepted.


Sign in / Sign up

Export Citation Format

Share Document