scholarly journals High-resolution mapping of gastric slow-wave recovery profiles: biophysical model, methodology, and demonstration of applications

2017 ◽  
Vol 313 (3) ◽  
pp. G265-G276 ◽  
Author(s):  
N. Paskaranandavadivel ◽  
L. K. Cheng ◽  
P. Du ◽  
J. M. Rogers ◽  
G. O’Grady

Slow waves play a central role in coordinating gastric motor activity. High-resolution mapping of extracellular potentials from the stomach provides spatiotemporal detail on normal and dysrhythmic slow-wave patterns. All mapping studies to date have focused exclusively on tissue activation; however, the recovery phase contains vital information on repolarization heterogeneity, the excitable gap, and refractory tail interactions but has not been investigated. Here, we report a method to identify the recovery phase in slow-wave mapping data. We first developed a mathematical model of unipolar extracellular potentials that result from slow-wave propagation. These simulations showed that tissue repolarization in such a signal is defined by the steepest upstroke beyond the activation phase (activation was defined by accepted convention as the steepest downstroke). Next, we mapped slow-wave propagation in anesthetized pigs by recording unipolar extracellular potentials from a high-resolution array of electrodes on the serosal surface. Following the simulation result, a wavelet transform technique was applied to detect repolarization in each signal by finding the maximum positive slope beyond activation. Activation-recovery (ARi) and recovery-activation (RAi) intervals were then computed. We hypothesized that these measurements of recovery profile would differ for slow waves recorded during normal and spatially dysrhythmic propagation. We found that the ARi of normal activity was greater than dysrhythmic activity (5.1 ± 0.8 vs. 3.8 ± 0.7 s; P < 0.05), whereas RAi was lower (9.7 ± 1.3 vs. 12.2 ± 2.5 s; P < 0.05). During normal propagation, RAi and ARi were linearly related with negative unit slope indicating entrainment of the entire mapped region. This relationship was weakened during dysrhythmia (slope: −0.96 ± 0.2 vs −0.71 ± 0.3; P < 0.05). NEW & NOTEWORTHY The theoretical basis of the extracellular gastric slow-wave recovery phase was defined using mathematical modeling. A novel technique utilizing the wavelet transform was developed and validated to detect the extracellular slow-wave recovery phase. In dysrhythmic wavefronts, the activation-to-recovery interval (ARi) was shorter and recovery-to-activation interval (RAi) was longer compared with normal wavefronts. During normal activation, RAi vs. ARi had a slope of −1, whereas the weakening of the slope indicated a dysrhythmic propagation.

2019 ◽  
Vol 25 (2) ◽  
pp. 276-285 ◽  
Author(s):  
Peng Du ◽  
Gregory O' ◽  
Grady ◽  
Niranchan Paskaranandavadivel ◽  
Shou-jiang Tang ◽  
...  

2016 ◽  
Vol 150 (4) ◽  
pp. S721
Author(s):  
Timothy R. Angeli ◽  
Niranchan Paskaranandavadivel ◽  
Peng Du ◽  
Samuel J. Asirvatham ◽  
Gianrico Farrugia ◽  
...  

2009 ◽  
Vol 136 (5) ◽  
pp. A-579-A-580
Author(s):  
Gregory O'Grady ◽  
Peng Du ◽  
John U. Egbuji ◽  
Wim Lammers ◽  
Leo K. Cheng ◽  
...  

2010 ◽  
Vol 138 (5) ◽  
pp. S-314
Author(s):  
John U. Egbuji ◽  
Gregory O'Grady ◽  
Peng Du ◽  
Leo K. Cheng ◽  
Wim Lammers ◽  
...  

2018 ◽  
Vol 30 (7) ◽  
pp. e13310 ◽  
Author(s):  
T. R. Angeli ◽  
G. O'Grady ◽  
R. Vather ◽  
I. P. Bissett ◽  
L. K. Cheng

2001 ◽  
Vol 280 (6) ◽  
pp. G1370-G1375 ◽  
Author(s):  
Xuemei Lin ◽  
Jiande Z. Chen

The aim of this study was to utilize multichannel electrogastrography to investigate whether patients with functional dyspepsia had impaired propagation or coordination of gastric slow waves in the fasting state compared with healthy controls. The study was performed in 10 patients with functional dyspepsia and 11 healthy subjects. Gastric myoelectrical activity was measured by using surface electrogastrography with a specially designed four-channel device. The study was performed for 30 min or more in the fasting state. Special computer programs were developed for the computation of the propagation and coupling of the gastric slow wave. It was found that, compared with the healthy controls, the patients showed a significantly lower percentage of slow wave propagation (58.0 ± 8.9 vs. 89.9 ± 2.6%, P < 0.002) and a significantly lower percentage of slow wave coupling (46.9 ± 4.4 vs. 61.5 ± 6.9%, P < 0.04). In addition, the patients showed inconsistencies in the frequency and regularity of the gastric slow wave among the four-channel electrogastrograms (EGGs). It was concluded that patients with functional dyspepsia have impaired slow wave propagation and coupling. Multichannel EGG has more information than single-channel EGG for the detection of gastric myoelectrical abnormalities.