scholarly journals Changes in left and right ventricular longitudinal function after pulmonary valve replacement in patients with Tetralogy of Fallot

2020 ◽  
Vol 318 (2) ◽  
pp. H345-H353 ◽  
Author(s):  
Pia Sjöberg ◽  
Ellen Ostenfeld ◽  
Erik Hedström ◽  
Håkan Arheden ◽  
Ronny Gustafsson ◽  
...  

Timing and indication for pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) are uncertain. To improve understanding of pumping mechanics, we investigated atrioventricular coupling before and after surgical PVR. Cardiovascular magnetic resonance was performed in patients ( n = 12) with rToF and PR > 35% before and after PVR and in healthy controls ( n = 15). Atrioventricular plane displacement (AVPD), global longitudinal peak systolic strain (GLS), atrial and ventricular volumes, and caval blood flows were analyzed. Right ventricular (RV) AVPD and RV free wall GLS were lower in patients before PVR compared with controls ( P < 0.0001; P < 0.01) and decreased after PVR ( P < 0.0001 for both). Left ventricular AVPD was lower in patients before PVR compared with controls ( P < 0.05) and decreased after PVR ( P < 0.01). Left ventricular GLS did not differ between patients and controls ( P > 0.05). Right atrial reservoir volume and RV stroke volume generated by AVPD correlated in controls ( r = 0.93; P < 0.0001) and patients before PVR ( r = 0.88; P < 0.001) but not after PVR. In conclusion, there is a clear atrioventricular coupling in patients before PVR that is lost after PVR, possibly because of loss of pericardial integrity. Impaired atrioventricular coupling complicates assessment of ventricular function after surgery using measurements of longitudinal function. Changes in atrioventricular coupling seen in patients with rToF may be energetically unfavorable, and long-term effects of surgery on atrioventricular coupling is therefore of interest. Also, AVPD and GLS cannot be used interchangeably to assess longitudinal function in rToF. NEW & NOTEWORTHY There is a clear atrioventricular coupling in patients with Tetralogy of Fallot (ToF) and pulmonary regurgitation before surgical pulmonary valve replacement (PVR) that is lost after operation, possibly because of loss of pericardial integrity. The impaired atrioventricular coupling complicates assessment of ventricular function after surgery when using measurements of longitudinal function. Left ventricular atrioventricular plane displacement (AVPD) found differences between patients and controls and changes after PVR that longitudinal strain could not detect. This indicates that AVPD and strain cannot be used interchangeably to assess longitudinal function in repaired ToF.

Heart ◽  
2017 ◽  
Vol 104 (9) ◽  
pp. 738-744 ◽  
Author(s):  
Jouke P Bokma ◽  
Tal Geva ◽  
Lynn A Sleeper ◽  
Sonya V Babu Narayan ◽  
Rachel Wald ◽  
...  

ObjectiveTo determine the association of pulmonary valve replacement (PVR) with death and sustained ventricular tachycardia (VT) in patients with repaired tetralogy of Fallot (rTOF).MethodsSubjects with rTOF and cardiac magnetic resonance from an international registry were included. A PVR propensity score was created to adjust for baseline differences. PVR consensus criteria were predefined as pulmonary regurgitation >25% and ≥2 of the following criteria: right ventricular (RV) end-diastolic volume >160 mL/m2, RV end-systolic volume >80 mL/m2, RV ejection fraction (EF) <47%, left ventricular EF <55% and QRS duration >160 ms. The primary outcome included (aborted) death and sustained VT. The secondary outcome included heart failure, non-sustained VT and sustained supraventricular tachycardia.ResultsIn 977 rTOF subjects (age 26±15 years, 45% PVR, follow-up 5.3±3.1 years), the primary and secondary outcomes occurred in 41 and 88 subjects, respectively. The HR for subjects with versus without PVR (time-varying covariate) was 0.65 (95% CI 0.31 to 1.36; P=0.25) for the primary outcome and 1.43 (95% CI 0.83 to 2.46; P=0.19) for the secondary outcome after adjusting for propensity and other factors. In subjects (n=426) not meeting consensus criteria, the HR for subjects with (n=132) versus without (n=294) PVR was 2.53 (95% CI 0.79 to 8.06; P=0.12) for the primary outcome and 2.31 (95% CI 1.07 to 4.97; P=0.03) for the secondary outcome.ConclusionIn this large multicentre rTOF cohort, PVR was not associated with a reduced rate of death and sustained VT at an average follow-up of 5.3 years. Additionally, there were more events after PVR compared with no PVR in subjects not meeting consensus criteria.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Alexis L Gerk ◽  
Michal Schafer ◽  
Benjamin Frank ◽  
Johannes von Alvensleben ◽  
Dunbar D IVY ◽  
...  

Introduction: Pulmonary regurgitation (PR) and RV dilation influence timing of pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rTOF). LV function is an independent marker of TOF patient outcomes. New markers of electromechanical discoordination (EMD) have recently been described. Systolic stretch fraction (SSF) quantifies the ratio of ventricular myocardium inappropriately relaxing during systole. Diastolic relaxation fraction (DRF) quantifies inappropriate myocardial contraction during diastole. We analyzed LV EMD using SSF and DRF in rTOF patients with PR who do not meet commonly used criteria for PVR with mild to moderate RV dilation (<150 mL/m 2 ). Hypothesis: Patients with rTOF will have abnormal LV EMD. Methods: Patients (n=18) and healthy controls (n=20) with rTOF and PR underwent cardiac MRI. LV EMD was analyzed using SSF and DRF (Figure) derived from strain and strain rate analysis considering individual LV myocardial segments. Rank-sum test was used to compare groups. SSF and DRF were assessed for linear correlations with RVEDVi by Pearson method. Results: There were 9 male and 9 female TOF patients (Mdn age 15, range 9-55). TOF patients had increased RVEDVi (118±23 ml/m 2 , p<0.001) and increased RVESVi (56±13 ml/m 2 , p<0.001) compared to controls. RV EF was lower in TOF patients but within normal physiologic range (53±6%, p=0.008). LV size indices and EF did not differ. TOF patients had increased SSF (Mdn 0.035, IQR 0.015-0.052, p=0.002) and significantly decreased DRF (Mdn 2.735, IQR 2.358-2.959, p<0.0001). RVEDVi correlated with increased SSF (R=0.51, p=0.011) and decreased DRF (R=0.62, p=0.007). Conclusions: TOF patients with PR and mild to moderate RV dilation have significant LV EMD during both systole and diastole. The degree of systolic and diastolic EMD correlate with RV dilation. SSF and DRF are unique and sensitive early markers of LV dysfunction compared to conventional MRI metrics.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Jamie K. Harrington ◽  
Sunil Ghelani ◽  
Nikhil Thatte ◽  
Anne Marie Valente ◽  
Tal Geva ◽  
...  

Abstract Background In repaired tetralogy of Fallot (rTOF), abnormal left ventricular (LV) rotational mechanics are associated with adverse clinical outcomes. We performed a comprehensive analysis of LV rotational mechanics in rTOF patients using cardiac magnetic resonance (CMR) prior to and following surgical pulmonary valve replacement (PVR). Methods In this single center retrospective study, we identified rTOF patients who (1) had both a CMR ≤ 1 year before PVR and ≤ 5 years after PVR, (2) had no other intervening procedure between CMRs, (3) had a body surface area > 1.0 m2 at CMR, and (4) had images suitable for feature tracking analysis. These subjects were matched to healthy age- and sex-matched control subjects. CMR feature tracking analysis was performed on a ventricular short-axis stack of balanced steady-state free precession images. Measurements included LV basal and apical rotation, twist, torsion, peak systolic rates of rotation and torsion, and timing of events. Associations with LV torsion were assessed. Results A total of 60 rTOF patients (23.6 ± 7.9 years, 52% male) and 30 healthy control subjects (20.8 ± 3.1 years, 50% male) were included. Compared with healthy controls, rTOF patients had lower apical and basal rotation, twist, torsion, and systolic rotation rates, and these parameters peaked earlier in systole. The only parameters that were correlated with LV torsion were right ventricular (RV) end-systolic volume (r = − 0.28, p = 0.029) and RV ejection fraction (r = 0.26, p = 0.044). At a median of 1.0 year (IQR 0.5–1.7) following PVR, there was no significant change in LV rotational parameters versus pre-PVR despite reductions in RV volumes, RV mass, pulmonary regurgitation, and RV outflow tract obstruction. Conclusion In this comprehensive study of CMR-derived LV rotational mechanics in rTOF patients, rotation, twist, and torsion were diminished compared to controls and did not improve at a median of 1 year after PVR despite favorable RV remodeling.


2019 ◽  
Vol 10 (2) ◽  
pp. 197-205 ◽  
Author(s):  
Chi Sum Yuen ◽  
Kwok Fai Lucius Lee ◽  
Inderjeet Bhatia ◽  
Nicholson Yam ◽  
Barnabe Antonio Rocha ◽  
...  

Background: Postcongenital heart surgery pulmonary regurgitation requires subsequent pulmonary valve replacement. We sought to compare the outcomes of pulmonary valve replacement after using bioprosthetic valves, porcine versus pericardial bioprosthesis. Method: Retrospective single-center study of consecutive pulmonary valve replacement in patients with pulmonary regurgitation following initial congenital cardiac surgery. From 2004 to 2016, 82 adult patients (53 males, 29 females) underwent pulmonary valve replacement at a mean age of 28.7 ± 8 years (range 18-52 years) with a mean time to pulmonary valve replacement of 24 ± 7 years (range 13-43 years). Porcine bioprosthetic valves (group 1, n = 32) and pericardial valves (group 2, n = 50) were used. Cardiac magnetic resonance imaging was performed (n = 54) at a mean of 18 ± 13 months before and 24 ± 21 months after pulmonary valve replacement. Results: No significant difference was seen between the groups except that the mean follow-up was longer for group 1 (5.02 ± 2.06 vs 4.08 ± 3.21 years). In-hospital mortality was 1.1%. Follow-up completeness was 100% with no late death. Mean right ventricular end-systolic and end-diastolic volumes reduced significantly in both the groups ( P < .001), whereas right ventricular ejection fraction remained unchanged (group 1, P = .129; group 2, P = .675) . Only the left ventricular end-diastolic volume increased in both the groups, but the increase was significant for group 2 only (group 1, P = .070; group 2, P = .015), whereas the left ventricular end-systolic and ejection fraction remained unchanged in both the groups. There was no reoperation for pulmonary valve replacement. Freedom from intervention was 93.8% (group 1) and 100% (group 2) at eight years after pulmonary valve replacement ( P = .407). Conclusion: Midterm outcomes of pulmonary valve replacement in our adult cohort were satisfactory. Both types of bioprosthetic valves performed comparably for eight years and were a good option in adults.


Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


Sign in / Sign up

Export Citation Format

Share Document