scholarly journals Semirigid Cantilever Extension System for Splinting Implants: A Clinical Report

2014 ◽  
Vol 2014 ◽  
pp. 1-6
Author(s):  
Raissa Micaella Marcello Machado ◽  
Luciana de Rezende Pinto ◽  
Otacílio Luiz Chagas Júnior ◽  
Fernanda Faot

In mandibular edentulous patients, treatment based on immediate loading with rigid splinting in the mandible is well accepted; however, it is cost and time dependent, which sometimes limits this type of rehabilitation. To overcome these problems, the technique of immediate loading using a semirigid splinting extension system has been developed. Its advantages include low cost, technical feasibility, and reduced clinic time. This clinical report presents the applicability and the predictability of semirigid splinting of implants in the mandibular arch of an edentulous patient using adistal extension bar prosthesis system.

2003 ◽  
Vol 12 (1) ◽  
pp. 26-29
Author(s):  
Maria Chatzistavrou ◽  
David A. Felton ◽  
Lyndon F. Cooper

2004 ◽  
Vol 6 (2) ◽  
pp. 111-119 ◽  
Author(s):  
Thomas Fortin ◽  
Michel Michel Isidori ◽  
Eric Eric Blanchet ◽  
Michel Michel Perriat ◽  
Hervé Hervé Bouchet ◽  
...  

2003 ◽  
Vol 12 (1) ◽  
pp. 26-29 ◽  
Author(s):  
Maria Chatzistavrou ◽  
David A. Felton ◽  
Lyndon F. Cooper

2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
Alisha Rewari ◽  
Nupur Dabas ◽  
Reshu Sanan ◽  
Shefali Phogat ◽  
Sumit Singh Phukela ◽  
...  

Summary. Prosthetic rehabilitation of a completely edentulous patient is no more confined to replacement of missing teeth. Long span of edentulism and ageing leads to loss of support of the facial musculature, which is of great concern in treating completely edentulous patients. Flaccid facial musculature eventually leads to sunken cheeks and unesthetic appearance, causing a negative impact on psychological well-being of the patient. The use of conventional complete dentures can restore the loss to some extent, but in some cases, additional support is required. The present clinical report exemplifies the use of magnet-retained detachable maxillary cheek plumper prosthesis in a completely edentulous patient with sunken cheeks.


Author(s):  
Jesús Peláez Rico ◽  
Jorge Cortés-Bretón Brinkmann ◽  
María Carrión Martín ◽  
Mabel Albanchez González ◽  
Celia Tobar Arribas ◽  
...  

The aim of this clinical report is to describe a maxillary full-arch implant supported restoration with immediate loading performed by means of an entirely digital workflow with photogrammetric system and intraoral scanning. A female patient with an edentulous maxillary arch attended the dental clinic seeking a maxillary fixed restoration. After treatment planning, six implants were placed using a surgical splint fabricated digitally by intraoral scanning of her previous removable prosthesis. Multi-unit abutments were fitted and two digital impressions were taken, one with a photogrammetric system for determining implant positions, and the other with an intraoral scanner for soft tissue registration. The acrylic resin structure of the immediate prosthesis was milled and placed within 8 hours of implant surgery. This provisional structure fitted correctly and provided adequate esthetics and function. Radiographic and clinical follow-up after 24 months observed adequate implant evolution.


Author(s):  
Luis Cuadrado ◽  
Cristina Canals Salinas ◽  
Cristina Cuadrado Canals ◽  
Andrea Sánchez Becerra ◽  
Luis Cuadrado Canals

Author(s):  
Francesco Mangano ◽  
Uli Hauschild ◽  
Oleg Admakin

Background: Guided implant surgery appears to have several benefits, such as the possibility of inserting flapless implants in a prosthetically driven manner, avoiding dangerous anatomical structures. However, to date, only a few surgeons routinely use guided surgery in partially edentulous patients. Aim: To present the results obtained with tooth-supported surgical templates characterized by an innovative open design with selective support, and manufactured via a full in-office procedure with a low-cost desktop 3D printer. Methods: Over a two-year period (2016–2018), all partially edentulous patients with one to three missing teeth (in maxilla and/or mandible), referred to a private dental practice for restoration with dental implants, were considered for inclusion in this prospective clinical study. An intraoral scanner (CS 3600®, Carestream Dental) and cone beam computed tomography (CS 9300®, Carestream Dental) were used to acquire the 3D information on the patients. Guided surgery software (SMOP®, Swissmeda) was used to plan the surgeries and to design open, selective, tooth-supported templates that were fabricated with a stereolithographic (SLA) desktop 3D printer (XFAB2000®, DWS). Guided implant surgeries were performed and patients were followed for a period of one year. The study outcomes were fit and stability of surgical templates, duration (time) of surgery, intra and post-operative complications, and implant stability and survival. Results: Twenty (20) partially edentulous patients (9 males, 11 females; mean age 54.4 ± 9.4 years) were included in the study; 28 open, selective, tooth-supported templates were designed with the aim of inserting 38 implants. Among the surgical templates, 24 had optimal fit and stability, three had optimal fit and sufficient stability, and only one had inadequate fit and unsatisfactory stability and was therefore not suitable for clinical use. The average time of the intervention was 15.7 ± 5.2 min per template. No intra-operative complications were reported, but one implant was not stable at placement and had to be removed. In total, 36 implants were restored with 10 two-unit fixed partial prostheses and 16 single crowns. All implants were successfully functioning at one year, even if, in two single crowns, minor prosthetic complications (abutment screw loosening) occurred. Conclusions: Full in-office guided surgery with open, selective, tooth-supported templates seem to represent a clinically predictable surgical procedure to restore partially edentulous patients. Further studies are needed to confirm these positive outcomes.


Sign in / Sign up

Export Citation Format

Share Document