scholarly journals Research on Distribution Network Security Analysis Based onK(N-1+k)Criterion and Rank Preference Optimal Ordering

2014 ◽  
Vol 2014 ◽  
pp. 1-6
Author(s):  
Wang Zengping ◽  
Yao Yuhai ◽  
Yu Junya ◽  
Yun Chentai

The objective of security analysis is to find the weak link of distribution network. TheK(N-1+k)criterion based on the characteristics of distribution network was proposed for distribution network security analysis. According to theK(N-1+k)criterion, the electrical devices in the contingency set can be classified into two kinds. The first kind meets the requirement of theK(N-1+k)criterion. The rank preference optimal ordering (RPOO) was proposed to evaluate the damage degree of power system. The second kind does not meet the requirement of theK(N-1+k)criterion, and it is the weak link of distribution network. A numerical experiment shows that the method is efficient and feasible, and the proposed method can provide assistant decision-making for safety precautions.

2010 ◽  
Vol 69 (7) ◽  
pp. 629-638
Author(s):  
J. Sisniega-Gonzalez ◽  
E. Aguirre-Anaya ◽  
Mariko Nakano-Miyatake ◽  
Hector Manuel Perez-Meana

2015 ◽  
Vol 775 ◽  
pp. 409-414
Author(s):  
Bing Jun Li ◽  
Su Quan Zhou ◽  
Xiao Xiang Lun

It is of great importance to identify the location of the harmonic sources for the harmonic governance in the power system. Applied with optimal measurement placement (OMP) and harmonic state estimation (HSE), this paper presents a novel process based on PMU measurements to locate the harmonic sources in the distribution network. Considering the cost and the observability, the OMP can provide a scheme of the measurement placement with the minimum number of PMU measurements. In order to simplify the HSE equation, the measured data are converted to the form of voltage by the method proposed in this paper.By solving the HSE equation, the location and magnitude of the harmonic source are evaluated. The methodology is applied to the IEEE 33-bus system, and the obtained results are properly analyzed.


Electronics ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 442
Author(s):  
Marcin Jaraczewski ◽  
Ryszard Mielnik ◽  
Tomasz Gębarowski ◽  
Maciej Sułowicz

High requirements for power systems, and hence for electrical devices used in industrial processes, make it necessary to ensure adequate power quality. The main parameters of the power system include the rms-values of the current, voltage, and active and reactive power consumed by the loads. In previous articles, the authors investigated the use of low-frequency sampling to measure these parameters of the power system, showing that the method can be easily implemented in simple microcontrollers and PLCs. This article discusses the methods of measuring electrical quantities by devices with low computational efficiency and low sampling frequency up to 1 kHz. It is not obvious that the signal of 50–500 Hz can be processed using the sampling frequency of fs = 47.619 Hz because it defies the Nyquist–Shannon sampling theorem. This theorem states that a reconstruction of a sampled signal is only guaranteed possible for a bandlimit fmax < fs, where fmax is the maximum frequency of a sampled signal. Therefore, theoretically, neither 50 nor 500 Hz can be identified by such a low-frequency sampling. Although, it turns out that if we have a longer period of a stable multi-harmonic signal, which is band-limited (from the bottom and top), it allows us to map this band to the lower frequencies, thus it is possible to use the lower sampling ratio and still get enough precise information of its harmonics and rms value. The use of aliasing for measurement purposes is not often used because it is considered a harmful phenomenon. In our work, it has been used for measurement purposes with good results. The main advantage of this new method is that it achieves a balance between PLC processing power (which is moderate or low) and accuracy in calculating the most important electrical signal indicators such as power, RMS value and sinusoidal-signal distortion factor (e.g., THD). It can be achieved despite an aliasing effect that causes different frequencies to become indistinguishable. The result of the research is a proposal of error reduction in the low-frequency measurement method implemented on compact PLCs. Laboratory tests carried out on a Mitsubishi FX5 compact PLC controller confirmed the correctness of the proposed method of reducing the measurement error.