scholarly journals Transducer Type and Design Influence on the Hearing Loss Compensation Behaviour of the Electromagnetic Middle Ear Implant in a Finite Element Analysis

2014 ◽  
Vol 6 ◽  
pp. 867108 ◽  
Author(s):  
Houguang Liu ◽  
Shirong Ge ◽  
Gang Cheng ◽  
Jianhua Yang ◽  
Zhushi Rao ◽  
...  

Several types of electromagnetic transducer for the middle ear implants (MEIs) have been developed as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Electromagnetic transducer type and design are thought to have a significant influence on their hearing compensation performance. To investigate these effects, a middle ear computational model was constructed based on a complete set of microcomputerized tomography section images of a human ear. Its validity was confirmed by comparing the model predicted motions with published experimental measurements. The result shows that the eardrum driving transducer (EDT) is superior to the floating mass transducer (FMT) in hearing compensation when the transducer mass is small but inferior to the FMT when the mass gets bigger. The incus body driving transducer (IBDT) is the most ineffective type of transducer for hearing compensation. Moreover, the masses of the EDT and the FMT decrease the transducer performance mainly at higher frequencies: the greater the transducer mass, the lower the displacement of the stapes excited by these transducers. On the other hand, the IBDT driving rod stiffness decreases transducer's performance severely at low frequencies and its adverse effect on transducer performance increases with the decrease of the stiffness of the IBDT driving rod.

2013 ◽  
Vol 127 (S2) ◽  
pp. S8-S16 ◽  
Author(s):  
C L Butler ◽  
P Thavaneswaran ◽  
I H Lee

AbstractIntroduction:This systematic review aims to advise on the effectiveness of the active middle-ear implant in patients with sensorineural hearing loss, compared with external hearing aids.Methods:A systematic search of several electronic databases, including PubMed and Embase, was used to identify relevant studies for inclusion.Results:Fourteen comparative studies were included. Nine studies reported on the primary outcome of functional gain: one found that the middle-ear implant was significantly better than external hearing aids (p < 0.001), while another found that external hearing aids were generally significantly better than middle-ear implants (p < 0.05). Six of the seven remaining studies found that middle-ear implants were better than external hearing aids, although generally no clinically significant difference (i.e. ≥10 dB) was seen.Conclusion:Generally, the active middle-ear implant appears to be as effective as the external hearing aid in improving hearing outcomes in patients with sensorineural hearing loss.


1976 ◽  
Vol 14 (12) ◽  
pp. 45-46

Up to 3 million people in Britain might be helped by hearing aids.1 2 Most are over 65 years of age, but some are infants. All should be referred to specialist centres for assessment as soon as possible. Hearing aids generally help most in disorders of the middle ear (conductive hearing loss); they can also help those with sensorineural and other forms of hearing loss. The use of an aid often needs to be supplemented by lip reading and other means of auditory training.1 3


2020 ◽  
Vol 124 ◽  
pp. 103918
Author(s):  
Houguang Liu ◽  
Wenbo Wang ◽  
Yu Zhao ◽  
Jianhua Yang ◽  
Shanguo Yang ◽  
...  

2017 ◽  
Vol 138 (1) ◽  
pp. 31-35 ◽  
Author(s):  
Maurizio Barbara ◽  
Luigi Volpini ◽  
Chiara Filippi ◽  
Francesca Atturo ◽  
Simonetta Monini

2020 ◽  
Vol 25 (3) ◽  
pp. 133-142
Author(s):  
Nina Wardenga ◽  
Ad F.M. Snik ◽  
Eugen Kludt ◽  
Bernd Waldmann ◽  
Thomas Lenarz ◽  
...  

Background: The conventional therapy for severe mixed hearing loss is middle ear surgery combined with a power hearing aid. However, a substantial group of patients with severe mixed hearing loss cannot be treated adequately with today’s state-of-the-art (SOTA) power hearing aids, as predicted by the accompanying part I of this publication, where we compared the available maximum power output (MPO) and gain from technical specifications to requirements for optimum benefit using a common fitting rule. Here, we intended to validate the theoretical assumptions from part I experimentally in a mixed hearing loss cohort fitted with SOTA power hearing aids. Additionally, we compared the results with an implantable hearing device that circumvents the impaired middle ear, directly stimulating the cochlea, as this might be a better option. Objectives: Speech recognition outcomes obtained from patients with severe mixed hearing loss supplied acutely with a SOTA hearing aid were studied to validate the outcome predictions as described in part I. Further, the results obtained with hearing aids were compared to those in direct acoustic cochlear implant (DACI) users. Materials and Methods: Twenty patients (37 ears with mixed hearing loss) were provided and fitted with a SOTA power hearing aid. Before and after an acclimatization period of at least 4 weeks, word recognition scores (WRS) in quiet and in noise were studied, as well as the speech reception threshold in noise (SRT). The outcomes were compared retrospectively to a second group of 45 patients (47 ears) using the DACI device. Based on the severity of the mixed hearing loss and the available gain and MPO of the SOTA hearing aid, the hearing aid and DACI users were subdivided into groups with prediction of sufficient, partially insufficient, or very insufficient hearing aid performance. Results: The patients with predicted adequate SOTA hearing aid performance indeed showed the best WRS in quiet and in noise when compared to patients with predicted inferior outcomes. Insufficient hearing aid performance at one or more frequencies led to a gradual decrease in hearing aid benefit, validating the criteria used here and in the accompanying paper. All DACI patients showed outcomes at the same level as the adequate hearing aid performance group, being significantly better than those of the groups with inadequate hearing aid performance. Whereas WRS in quiet and noise were sensitive to insufficient gain or output, showing significant differences between the SOTA hearing aid and DACI groups, the SRT in noise was less sensitive. Conclusions: Limitations of outcomes in mixed hearing loss individuals due to insufficient hearing aid performance can be accurately predicted by applying a commonly used fitting rule and the 35-dB dynamic range rule on the hearing aid specifications. Evidently, when outcomes in patients with mixed hearing loss using the most powerful hearing aids are insufficient, bypassing the middle ear with a powerful active middle ear implant or direct acoustic implant can be a promising alternative treatment.


2002 ◽  
Vol 11 (1) ◽  
pp. 29-41 ◽  
Author(s):  
Todd Ricketts ◽  
Paula Henry

Hearing aids currently available on the market with both omnidirectional and directional microphone modes often have reduced amplification in the low frequencies when in directional microphone mode due to better phase matching. The effects of this low-frequency gain reduction for individuals with hearing loss in the low frequencies was of primary interest. Changes in sound quality for quiet listening environments following gain compensation in the low frequencies was of secondary interest. Thirty participants were fit with bilateral in-the-ear hearing aids, which were programmed in three ways while in directional microphone mode: no-gain compensation, adaptive-gain compensation, and full-gain compensation. All participants were tested with speech in noise tasks. Participants also made sound quality judgments based on monaural recordings made from the hearing aid. Results support a need for gain compensation for individuals with low-frequency hearing loss of greater than 40 dB HL.