Abstract P4-15-02: Timing of infectious complications following breast conserving therapy with catheter-based accelerated partial breast irradiation

Author(s):  
AB Haynes ◽  
ES Bloom ◽  
I Bedrosian ◽  
HM Kuerer ◽  
RF Hwang ◽  
...  
2014 ◽  
Vol 21 (8) ◽  
pp. 2512-2516 ◽  
Author(s):  
Alex B. Haynes ◽  
Elizabeth S. Bloom ◽  
Isabelle Bedrosian ◽  
Henry M. Kuerer ◽  
Rosa F. Hwang ◽  
...  

2005 ◽  
Vol 1 (1) ◽  
pp. 59-71
Author(s):  
Timothy M Pawlik ◽  
Henry M Kuerer

Breast-conserving therapy has been established as a standard treatment for women with early-stage breast cancer. Whole-breast irradiation has traditionally been utilized to consolidate local therapy following conservative surgery. Recently, the need for whole-breast irradiation after breast-conserving surgery has become controversial, with some investigators advocating accelerated partial breast irradiation as an alternative. Accelerated partial breast irradiation is delivered over a shorter period and only to a portion of the breast. This review will examine the emerging role of accelerated partial breast irradiation in the treatment of early-stage breast cancer and review the biologic rationale for, techniques of, and limitations of partial breast irradiation following breast-conserving surgery.


2009 ◽  
Vol 75 (11) ◽  
pp. 1042-1049
Author(s):  
Philip Z. Israel ◽  
Angela B. Robbins ◽  
Paulomi Shroff ◽  
Kenneth Haile ◽  
D. Keith Pope

We reviewed our surgical experience with the Contura® Multi Lumen Balloon breast brachytherapy catheter used to deliver accelerated partial breast irradiation and determined short-term treatment efficacy, cosmesis, and toxicity. Forty-six patients undergoing breast conserving therapy, including the use of Contura® catheter, were analyzed. Thirty-four Gray were delivered in 10 fractions. Fourteen patients had stage 0, 24 had stage I, and 8 had stage II breast cancer. Catheters were placed with a closed cavity technique. Median minimum skin spacing was 10 mm (range, 2-18 mm). Median maximum skin doses were 99.7 per cent of the prescription dose. Nine patients were treated with a skin spacing ≤5 mm (2 patients with 2 mm skin spacing). The percentage of patients with excellent/good cosmesis at 6 (n = 26) and 12 (n = 13) months was 100 per cent, respectively. Patient tolerance was assessed on a scale of 0-10 (0 = no pain, 10 = requiring narcotic analgesics). Pain was graded ≤3 in 98 per cent of patients at catheter insertion and 84 per cent at catheter removal. Four breast infections (8.8%) and one symptomatic seroma developed. Adjuvant accelerated partial breast irradiation using the Contura Multi Lumen Balloon exhibited similar toxicities to standard single lumen, single dwell balloon brachytherapy with improvements in dosimetric capabilities allowing the treatment of patients with skin spacing ≤5 mm.


Sign in / Sign up

Export Citation Format

Share Document