Abstract 2157: Eliminating Edge Effect in 96-Well Plates by Controlling Thermal Conditions during Cell Plating

Author(s):  
Shannon Darou ◽  
Alicia Henn ◽  
Kersti Alm ◽  
Allayna M. Frank ◽  
Randy Yerden
2019 ◽  
Author(s):  
Shannon Darou ◽  
Alicia Henn ◽  
Kersti Alm ◽  
Allayna M. Frank ◽  
Randy Yerden

2018 ◽  
pp. 155-162 ◽  
Author(s):  
Sergei S. Kapitonov ◽  
Anastasia V. Kapitonova ◽  
Sergei Yu. Grigorovich ◽  
Sergei A. Medvedev ◽  
Taher Sobhy

In the article, the electrical and thermal processes in the LED lamp with varied parameters are investigated. Voltage and current measurements on all LEDs of the luminaire are carried out in the nominal operating mode. The power allocated to each LED is determined. The calculation of the LED crystal temperature was carried out using the developed thermal LED model based on the results of the measurements and by using “Multisim” program. It has been established that the temperature of the crystals of individual LEDs in the luminaire differ significantly, which leads to unfavourable thermal conditions for them and an increased likelihood of premature failure.


2016 ◽  
Vol 11 (4) ◽  
pp. 441
Author(s):  
Marina Gumerova ◽  
Flur Ismagilov ◽  
Irek Khairullin ◽  
Viacheslav Vavilov ◽  
Oksana Yushkova ◽  
...  

2017 ◽  
Vol 191 ◽  
pp. 176-195 ◽  
Author(s):  
Igor D. Rostov ◽  
Elena V. Dmitrieva ◽  
Alexander A. Vorontsov

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


Sign in / Sign up

Export Citation Format

Share Document