Inspiratory and Expiratory Resistive Loading as a Model of Dyspnea in Asthma

Respiration ◽  
1983 ◽  
Vol 44 (6) ◽  
pp. 425-432 ◽  
Author(s):  
K.R. Chapman ◽  
A.S. Rebuck
Keyword(s):  
1986 ◽  
Vol 26 (8) ◽  
pp. 1097-1102 ◽  
Author(s):  
S. Shinohara ◽  
O. Naito ◽  
K. Miyamoto
Keyword(s):  

2000 ◽  
Vol 162 (5) ◽  
pp. 1627-1632 ◽  
Author(s):  
GIORA PILLAR ◽  
ATUL MALHOTRA ◽  
ROBERT FOGEL ◽  
JOSÉE BEAUREGARD ◽  
ROBERT SCHNALL ◽  
...  

CHEST Journal ◽  
2000 ◽  
Vol 118 (5) ◽  
pp. 1332-1338 ◽  
Author(s):  
Ye Tun ◽  
Wataru Hida ◽  
Shinichi Okabe ◽  
Yoshihiro Kikuchi ◽  
Hajime Kurosawa ◽  
...  

2021 ◽  
Author(s):  
Ling Liu ◽  
Daijiro Takahashi ◽  
Haibo Qui ◽  
Arthur S. Slutsky ◽  
Christer Sinderby ◽  
...  

Background During conventional Neurally Adjusted Ventilatory Assist (NAVA), the electrical activity of the diaphragm (EAdi) is used for triggering and cycling-off inspiratory assist, with a fixed PEEP (so called “Triggered Neurally Adjusted Ventilatory Assist” or “tNAVA”). However, significant post-inspiratory activity of the diaphragm can occur, believed to play a role in maintaining end-expiratory lung volume. Adjusting pressure continuously, in proportion to both inspiratory and expiratory EAdi (Continuous NAVA, or cNAVA), would not only offer inspiratory assist for tidal breathing, but also may aid in delivering a “neurally adjusted PEEP”, and more specific breath-by-breath unloading. Methods Nine adult New Zealand white rabbits were ventilated during independent conditions of: resistive loading (RES1 or RES2), CO2 load (CO2) and acute lung injury (ALI), either via tracheotomy (INV) or non-invasively (NIV). There were a total of six conditions, applied in a non-randomized fashion: INV-RES1, INV-CO2, NIV-CO2, NIV-RES2, NIV-ALI, INV-ALI. For each condition, tNAVA was applied first (3 min), followed by 3 min of cNAVA. This comparison was repeated 3 times (repeated cross-over design). The NAVA level was always the same for both modes, but was newly titrated for each condition. PEEP was manually set to zero during tNAVA. During cNAVA, the assist during expiration was proportional to the EAdi. During all runs and conditions, ventilator-delivered pressure (Pvent), esophageal pressure (Pes), and diaphragm electrical activity (EAdi) were measured continuously. The tracings were analyzed breath-by-breath to obtain peak inspiratory and mean expiratory values. Results For the same peak Pvent, the distribution of inspiratory and expiratory pressure differed between tNAVA and cNAVA. For each condition, the mean expiratory Pvent was always higher (for all conditions 4.0 ± 1.1 vs. 1.1 ± 0.5 cmH2O, P < 0.01) in cNAVA than in tNAVA. Relative to tNAVA, mean inspiratory EAdi was reduced on average (for all conditions) by 19 % (range 14 %–25 %), p < 0.05. Mean expiratory EAdi was also lower during cNAVA (during INV-RES1, INV-CO2, INV-ALI, NIV-CO2 and NIV-ALI respectively, P < 0.05). The inspiratory Pes was reduced during cNAVA all 6 conditions (p < 0.05). Unlike tNAVA, during cNAVA the expiratory pressure was comparable with that predicted mathematically (mean difference of 0.2 ± 0.8 cmH2O). Conclusion Continuous NAVA was able to apply neurally adjusted PEEP, which led to a reduction in inspiratory effort compared to triggered NAVA.


1985 ◽  
Vol 59 (5) ◽  
pp. 1527-1532 ◽  
Author(s):  
T. K. Aldrich ◽  
D. Appel

Diaphragmatic contractility was assessed in spontaneously breathing ketamine-anesthetized rabbits by measuring the strength of diaphragmatic contraction in response to bilateral supramaximal phrenic nerve stimulation at frequencies between 10 and 100 Hz. During 10–180 min of inspiratory resistive loading, contractility decreased by approximately 40%, and hypoxemia and both respiratory and lactic acidosis developed. After 10 min of recovery, both the response to high-frequency stimulation (100 Hz) and the arterial PO2 and PCO2 returned to base-line levels, whereas metabolic acidosis and reduced response to low-frequency stimulation (10–20 Hz) persisted. Similar levels of hypoxemia and respiratory acidosis in the absence of inspiratory resistive loading did not alter diaphragmatic contractility. We conclude that in anesthetized rabbits excessive inspiratory resistive loading results in partially reversible diaphragm fatigue of the high- and low-frequency types, accompanied by hypoventilation and lactic acidosis.


2020 ◽  
Vol 282 ◽  
pp. 103531
Author(s):  
Ching-Feng Cheng ◽  
Wei-Chieh Hsu ◽  
Yu-Hsuan Kuo ◽  
Tzu-Wei Chen ◽  
Yu-Chi Kuo

Sign in / Sign up

Export Citation Format

Share Document