scholarly journals Added Value of Digital Breast Tomosynthesis Combined with Digital Mammography According to Reader Agreement: Changes in BI-RADS Rate and Follow-Up Management

Breast Care ◽  
2017 ◽  
Vol 12 (4) ◽  
pp. 218-222 ◽  
Author(s):  
Francesca Galati ◽  
Flaminia Marzocca ◽  
Erica Bassetti ◽  
Maria L. Luciani ◽  
Sharon Tan ◽  
...  

Background: The aim of this study was to evaluate the added value of digital breast tomosynthesis (DBT) when combined with digital mammography (DM) in BI-RADS assessment and follow-up management. Methods: From February 2014 to January 2015, 214 patients underwent DM and DBT, acquired with a Siemens Mammomat Inspiration unit. 2 expert readers independently reviewed the studies in 2 steps: DM and DM+DBT, according to BI-RADS rate. Patients with BI-RADS 0, 3, 4, and 5 were recalled for work-up. Inter-reader agreement for BI-RADS rate and work-up rate were evaluated using Cohen's kappa. Results: Inter-reader agreement (κ value) for BI-RADS classification was 0.58 for DM and 0.8 for DM+DBT. DM+DBT increased the number of BI-RADS 1, 2, 4, 5 and reduced the number of BI-RADS 0 and 3 for both readers compared to DM alone. Regarding work-up rate agreement, κ was poor for DM and substantial (0.7) for DM+DBT. DM+DBT also reduced the work-up rate for both Reader 1 and Reader 2. Conclusion: DM+DBT increased the number of negative and benign cases (BI-RADS 1 and 2) and suspicious and malignant cases (BI-RADS 4 and 5), while it reduced the number of BI-RADS 0 and 3. DM+DBT also improved inter-reader agreement and reduced the overall recall for additional imaging or short-interval follow-up.

Author(s):  
L. Appelman ◽  
P. T. M. Appelman ◽  
C. C. N. Siebers ◽  
P. Bult ◽  
H. L. S. Go ◽  
...  

Abstract Purpose To determine the added value of mammography in women with focal breast complaints and the utility of initial targeted ultrasound in this setting. Methods Women with symptomatic breast disease who were evaluated by breast imaging (mammography/digital breast tomosynthesis and ultrasound) between January 2016 and December 2016 in the Radboud University Medical Centre were included. We retrospectively collected the following data: date of birth, indication of imaging, visibility on mammography/ultrasound, whether biopsy was taken, additional findings, BI-RADS-classification, pathology and follow-up results. Results A total of 494 women were included (mean age 46.5, range 30 to 93). In 49 women (9.9%), symptomatic breast cancer was diagnosed, all visible during targeted ultrasound. The negative predictive value of targeted ultrasound was very high (99.8%). Additional findings on mammography were significantly more often malignant when the symptomatic lesion was also malignant (3.8% vs 70%, P < 0.05). In only one patient with symptoms caused by a benign finding, an incidental malignancy was detected on mammography outside the area of complaint (detection rate 2.2/1000 examinations). Conclusions The contribution of mammography for cancer detection in women with focal breast complaints is very low when targeted ultrasound is performed. Additional findings are most common in patients with symptomatic breast cancer. Our results suggest that initial targeted ultrasound is a more appropriate initial tool for the evaluation of focal breast complaints. Mammography could be performed on indication only.


2020 ◽  
Vol 2 (5) ◽  
pp. 424-435
Author(s):  
Naziya Samreen ◽  
Linda Moy ◽  
Cindy S Lee

Abstract Architectural distortion on digital breast tomosynthesis (DBT) can occur due to benign and malignant causes. With DBT, there is an increase in the detection of architectural distortion compared with 2D digital mammography, and the positive predictive value is high enough to justify tissue sampling when imaging findings are confirmed. Workup involves supplemental DBT views and ultrasound, with subsequent image-guided percutaneous biopsy using the modality on which it is best visualized. If architectural distortion is subtle and/or questionable on diagnostic imaging, MRI may be performed for problem solving, with subsequent biopsy of suspicious findings using MRI or DBT guidance, respectively. If no suspicious findings are noted on MRI, a six-month follow-up DBT may be performed. On pathology, malignant cases are noted in 6.8%–50.7% of the cases, most commonly due to invasive ductal carcinoma, followed by invasive lobular carcinoma. Radial scars are the most common benign cause, with stromal fibrosis and sclerosing adenosis being much less common. As there is an increase in the number of benign pathological outcomes for architectural distortion on DBT compared with 2D digital mammography, concordance should be based on the level of suspicion of imaging findings. As discordant cases have upgrade rates of up to 25%, surgical consultation is recommended for discordant radiologic-pathologic findings.


Sign in / Sign up

Export Citation Format

Share Document