scholarly journals A novel wavelet packet transform based fault identification procedures in HV transmission line based on current signals

Author(s):  
Ahmed R. Adly ◽  
Ragab El Sehiemy ◽  
Mahmoud A. Elsadd ◽  
Almoataz Y. Abdelaziz

<p>This paper presents an adaptive fault identification algorithm bases on wavelet packet transform (WPT) for two-terminal power transmission lines. The proposed scheme performs four functions which are the fault detection, fault classification, distinguishing among the temporary and the permanent faults, and detection of the arc extinguish instant. The presented algorithm only uses the measured current at one terminal reducing the required cost. Also, it can mitigate the error resulting from the load variations via updating the presetting value. Consequently, it does not need retesting under changing the transmission system configurations. The proposed scheme is deduced in the spectral domain and depended on the application of the WPT. The db6 wavelet packet is used for decomposing the faulty phase current waveform (level 7) to get the energy coefficients. The presented algorithm is assessed under various fault conditions such as fault distances, inception angles, and faults nature via simulating different secondary arc models via using ATP/EMTP. The obtained results are investigated and evaluated.</p>

2016 ◽  
Vol 2016 (4) ◽  
pp. 8-10 ◽  
Author(s):  
B.I. Kuznetsov ◽  
◽  
A.N. Turenko ◽  
T.B. Nikitina ◽  
A.V. Voloshko ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1561
Author(s):  
Hao Chen ◽  
Zhongnan Qian ◽  
Chengyin Liu ◽  
Jiande Wu ◽  
Wuhua Li ◽  
...  

Current measurement is a key part of the monitoring system for power transmission lines. Compared with the conventional current sensor, the distributed, self-powered and contactless current sensor has great advantages of safety and reliability. By integrating the current sensing function and the energy harvesting function of current transformer (CT), a time-multiplexed self-powered wireless sensor that can measure the power transmission line current is presented in this paper. Two operating modes of CT, including current sensing mode and energy harvesting mode, are analyzed in detail. Through the design of mode-switching circuit, harvesting circuit and measurement circuit are isolated using only one CT secondary coil, which eliminates the interference between energy harvesting and current measurement. Thus, the accurate measurement in the current sensing mode and the maximum energy collection in the energy harvesting mode are both realized, all of which simplify the online power transmission line monitoring. The designed time-multiplexed working mode allows the sensor to work at a lower transmission line current, at the expense of a lower working frequency. Finally, the proposed sensor is verified by experiments.


IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Vedanta Pradhan ◽  
O. D. Naidu ◽  
Sinisa Zubic ◽  
Patrick Cost

Sign in / Sign up

Export Citation Format