Influence of Abutment Design and Platform Switching on Peri-implant Marginal Bone Level: A Randomized Controlled Clinical Trial with 1-Year Results

2021 ◽  
Vol 41 (4) ◽  
pp. 547-553
Author(s):  
Daniele Cardaropoli ◽  
Lorenzo Tamagnone ◽  
Alessandro Roffredo ◽  
Lorena Gaveglio
2020 ◽  
Vol 31 (10) ◽  
pp. 968-979
Author(s):  
Samir Abou‐Ayash ◽  
Martin Schimmel ◽  
Dominik Kraus ◽  
Regina Mericske‐Stern ◽  
Dominic Albrecht ◽  
...  

2021 ◽  
Vol 10 (16) ◽  
pp. 3475
Author(s):  
Markus Schlee ◽  
Hom-Lay Wang ◽  
Thomas Stumpf ◽  
Urs Brodbeck ◽  
Dieter Bosshardt ◽  
...  

Aim of the study: This RCT assesses patients’ 18-month clinical outcomes after the regenerative therapy of periimplantitis lesions using either an electrolytic method (EC) to remove biofilms or a combination of powder spray and an electrolytic method (PEC). Materials and Methods: Twenty-four patients (24 implants) suffering from periimplantitis were randomly treated by EC or PEC followed by augmentation and submerged healing. Probing pocket depth (PPD), Bleeding on Probing (BoP), suppuration, and standardized radiographs were assessed before surgery (T0), 6 months after augmentation (T1), and 6 (T2) and 12 (T3) months after the replacement of the restoration. Results: The mean PPD changed from 5.8 ± 1.6 mm (T0) to 3.1 ± 1.4 mm (T3). While BoP and suppuration at T0 were 100%, BoP decreased at T2 to 36.8% and at T3 to 35.3%. Suppuration was found to be at a level of 10.6% at T2 and 11.8% at T3. The radiologic bone level measured from the implant shoulder to the first visible bone to the implant contact was 4.9 ± 1.9 mm at mesial sites and 4.4 ± 2.2 mm at distal sites at T0 and 1.7 ± 1.7 mm and 1.5 ± 17 mm at T3. Conclusions: Significant radiographic bone fill and the improvement of clinical parameters were demonstrated 18 months after therapy.


Author(s):  
Markus Schlee ◽  
Hom-Lay Wang ◽  
Thomas Stumpf ◽  
Urs Brodbeck ◽  
Florian Rathe

Background: this RCT assesses the 18 months clinical outcomes after regenerative therapy of periimplantitis lesions using either an electrolytic method (EC) to remove biofilms or a combination of powder spray and electrolytic method (PEC). Materials and Methods: Twenty-four patients (24 implants) suffering from periimplantitis were randomly treated by EC or PEC followed by augmentation and submerged healing. Probing pocket depth (PPD), Bleeding on Probing (BoP), suppuration and standardized radiographs were assessed before surgery (T0), 6 months after augmentation (T1), 6 (T2) and 12 (T3) months after replacement of the restoration. Results: Mean of PPD changed from 5.8 ± 1.6 mm (T0) to 3.1 ± 1.4 mm (T3). While BoP and suppuration at T0 was 100 % BoP decreased at T2 to 36.8 % and at T3 to 35.3 %. Suppuration could be found 10.6% at T2 and 11.8% at T3. Radiologic bone level measured from the implant shoulder to the first visible bone to implant contact was 4.9 ± 1.9 mm at me-sial and 4.4 ± 2.2 mm at distal sites (T0) and 1.7 ± 1.7 mm and 1.5 ± 17 mm at T3. Conclusions: Significant radiographic bone fill and improvement of clinical parameters were demonstrated 18 months after therapy.


2011 ◽  
Vol 38 (4) ◽  
pp. 374-384 ◽  
Author(s):  
Norbert Enkling ◽  
Peter Jöhren ◽  
Torben Klimberg ◽  
Regina Mericske-Stern ◽  
Pia-Merete Jervøe-Storm ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document