Abstract 16920: Transcatheter Aortic Valve Replacement in Aortic Regurgitation: The U.S. Experience

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Chinmy T Jani ◽  
Shilpkumar Arora ◽  
Sopan Lahewala ◽  
ZACHARY ZUZEK ◽  
Rahul Jaswaney ◽  
...  

Background: Transcatheter aortic valve replacement (TAVR) may be an effective option for high-risk AR patients. Although international experiences of TAVR for AR are published, U.S. data is limited. The primary objective of this study was to investigate periprocedural and 30-days outcomes in terms of mortality and post-procedural complications in patients undergoing TAVR for AR using large national U.S. databases. Hypothesis: TAVR is a promising option in AR Methods: Study cohorts were derived from Nationwide Inpatient Sample (NIS) and Nationwide Readmissions Database (NRD) 2016-17. TAVR and AR were identified using ICD-10-CM-codes. The key outcomes were all-cause mortality, disabling stroke, valvular complications, complete heart block (CHB)/ permanent pacemaker placement (PPM), open heart surgery, acute kidney injury (AKI) requiring dialysis, and vascular complications. Multivariate logistic regression was used to adjust for confounders. Results: 915 patients from the NIS (male-71%, age 65-84.2%) and 822 patients from the NRD (male-69.3%, age 65-80.5%) underwent TAVR for AR. The median length of stay (LOS) was 4 days for both cohorts. In-hospital mortality was 2.7% in NIS and 30-day mortality was 3.3% in NRD. Disabling strokes were noted in 0.6% peri-procedurally and 1.8% at 30-days. Valve-related complications were 18-19% with paravalvular leak being the most common. Approximately 11% of patients developed CHB and/or needed PPM in both cohorts. In NRD, 2.2% of patients required dialysis for AKI, 1.5% developed vascular complications, and 0.6% required open-heart surgery within 30-days post-procedure. Anemia was predictive of increased overall complications and valvular complications, whereas, peripheral vascular disease was predictor of increased valvular complications and CHB/PPM. Conclusion: TAVR is a promising option in AR. Further studies are necessary for the expansion of TAVR as standard treatment in AR.

Author(s):  
Giorgia M. Bosi ◽  
Claudio Capelli ◽  
Robin Chung ◽  
Michael Mullen ◽  
Andrew M. Taylor ◽  
...  

In the past decade, Transcatheter Aortic Valve Replacement (TAVI) has been shown to be a feasible, less invasive option to open heart surgery for aortic valve replacement; however, TAVI is indicated only in patients with severe, symptomatic, aortic stenosis and who are considered at high or prohibitive risk for conventional surgery [1]. To date, two different TAVI devices are available on the market — the balloon-expandable Edwards-Sapien® Valve (Edwards Lifesciences, CA, USA) and the self-expandable CoreValve ReValving System® (Medtronic, MN, USA) — with many other devices currently under development and clinical trials. The procedural success rate has been >90% in all studies [1], but vascular complications, electrical conduction abnormalities and paravalvular leak — 65–89% of cases, the majority being trivial to mild, with 0 to 26% moderate and 0 to 10% severe — still remain major safety concerns. In particular, a negative influence of moderate to severe paravalvular leak on survival rates has recently been demonstrated [2].


2015 ◽  
Vol 42 (2) ◽  
pp. 172-174 ◽  
Author(s):  
Christine Pabilona ◽  
Bernard Gitler ◽  
Jeffrey A. Lederman ◽  
Donald Miller ◽  
Theodore N. Keltz

Patients with severe aortic stenosis who are at high risk for open-heart surgery might be candidates for transcatheter aortic valve replacement (TAVR). To our knowledge, this is the first report of Streptococcus viridans endocarditis that caused prosthetic valve obstruction after TAVR. A 77-year-old man who had undergone TAVR 17 months earlier was admitted because of evidence of prosthetic valve endocarditis. A transthoracic echocardiogram revealed a substantial increase in the transvalvular peak gradient and mean gradient in comparison with an echocardiogram of 7 months earlier. A transesophageal echocardiogram showed a 1.5-cm vegetation obstructing the valve. Blood cultures yielded penicillin-sensitive S. viridans. The patient was hemodynamically stable and was initially treated with vancomycin because of his previous penicillin allergy. Subsequent therapy with levofloxacin, oral penicillin (after a negative penicillin skin test), and intravenous penicillin eliminated the symptoms of the infection. Transcatheter aortic valve replacement is a relatively new procedure, and sequelae are still being discovered. We recommend that physicians consider obstructive endocarditis as one of these.


2019 ◽  
Vol 2019 ◽  
pp. 1-8 ◽  
Author(s):  
Gaurav Rao ◽  
Shikha Sheth ◽  
Joseph Donnelly ◽  
Andrew Scatola ◽  
Umair Tariq ◽  
...  

Objectives. The purpose of this study was to compare the efficacy and safety of the Evolut PRO to the Evolut R valve in a real-world setting. Background. The next-generation self-expanding transcatheter aortic valve replacement (TAVR) system, the CoreValve Evolut PRO was designed with an outer pericardial skirt to improve valve-sealing performance. Safety and efficacy of this valve have not previously been compared to its predecessor, the Evolut R valve. Methods. We retrospectively studied 134 patients who underwent TAVR with the Evolut PRO or Evolut R valve over one year at a tertiary center. Endpoints, defined by the Valve Academic Research Consortium-2 criteria, included device success, paravalvular leak (PVL), and a composite safety endpoint including mortality, stroke, major vascular complications, life-threatening bleeding, acute kidney injury, coronary artery obstruction, and repeat procedure for valve-related dysfunction. Results. 60 Evolut PRO and 56 Evolut R patients met the study criteria. Both groups had similar device success rates (90 vs. 89%, p=0.44). Incidence of moderate PVL was similar on discharge (5 vs. 11%, p=0.68) and at 30 days (11 vs. 13%, p=0.79), with nil incidence of severe PVL. There were no mortalities, and the VARC-2 safety endpoint at 30 days was comparable. Conclusion. Despite the additional pericardial skirt and larger sheath size of Evolut PRO, outcomes were comparable between the two Evolut systems, supporting adoption of the newest generation valve in the management of severe aortic stenosis as well as continued use of the Evolut R in patients with smaller vasculature warranting a lower profile device.


2018 ◽  
pp. bcr-2017-224069
Author(s):  
Nathan W Furukawa ◽  
Fernando M Jumalon ◽  
Daniel B Friedman ◽  
Linda R Kelly

A 78-year-old man with a history of severe aortic stenosis presented with confusion, irregular behaviour and dyspnoea 8 days following transcatheter aortic valve replacement. His exam was consistent with a heart failure exacerbation and he had elevated aminotransferases, bilirubin and prothrombin time suggestive of shock liver. A CT head scan demonstrated a subacute large left temporoparietal infarction. His aminotransferase and prothrombin time levels normalised with diuresis, but his indirect bilirubin remained elevated and he developed anaemia and thrombocytopenia consistent with a haemolytic anaemia. A transthoracic echocardiogram demonstrated a paravalvular leak. His thrombocytopenia continued to worsen prompting testing for antibodies against heparin-PF4 complexes which was positive. A serotonin release assay later returned positive, confirming the diagnosis of heparin-induced thrombocytopenia. This case illustrates that the presence of haemolytic anaemia does not necessarily exclude other causes of thrombocytopenia that may occur concurrently.


Sign in / Sign up

Export Citation Format

Share Document