scholarly journals Reversal of Severe Heart Failure With a Continuous-Flow Left Ventricular Assist Device and Pharmacological Therapy

Circulation ◽  
2011 ◽  
Vol 123 (4) ◽  
pp. 381-390 ◽  
Author(s):  
Emma J. Birks ◽  
Robert S. George ◽  
Mike Hedger ◽  
Toufan Bahrami ◽  
Penny Wilton ◽  
...  
2015 ◽  
Vol 82 (2) ◽  
Author(s):  
David Simoni ◽  
Martina Rafanelli ◽  
Andrea Ungar ◽  
Enrico Mossello ◽  
Niccolò Marchionni ◽  
...  

The increase of severe heart failure and the consequent reduction of the organ availability for transplantation has led to, in recent years, the introduction of the LVAD as replacement therapy to heart transplantation. Severe Heart Failure patients show cognitive deficits in various domains especially in executive functions, memory and speed of proceedings, due to different neurophysiopathological processes including chronic hypoperfusion and subsequent damage to hippocampal and para-hippocampal cortical areas. It is also known that these deficits improve after heart transplantation. We carried out a literature review selecting studies that analyzed the cognitive changes in patients with severe heart failure after implantation of the Continuous Flow Left Ventricular Assist Device. According to the inclusion criteria, we selected four studies since 2005 that presented a comprehensive neurocognitive assessment. The results show that the cognitive profile, with the implantation of LVAD improves in memory and executive domains, and this improvements results stable in short- medium time. The effects would also be independent of the type of flow produced by the device (pulsatile vs continuous). We believe that further studies are required to explore the relationship between LVAD and cognitive function in severe heart failure.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Selim Bozkurt ◽  
Koray K. Safak

Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state of donor organ supply. In this study, the hemodynamic response of a cardiovascular system that includes a dilated cardiomyopathic heart under support of a newly developed continuous flow left ventricular assist device—Heart Turcica Axial—was evaluated employing computer simulations. For the evaluation, a numerical model which describes the pressure-flow rate relations of Heart Turcica Axial, a cardiovascular system model describing the healthy and pathological hemodynamics, and a baroreflex model regulating the heart rate were used. Heart Turcica Axial was operated between 8000 rpm and 11000 rpm speeds with 1000 rpm increments for assessing the pump performance and response of the cardiovascular system. The results also give an insight about the range of the possible operating speeds of Heart Turcica Axial in a clinical application. Based on the findings, operating speed of Heart Turcica Axial should be between 10000 rpm and 11000 rpm.


Sign in / Sign up

Export Citation Format

Share Document