Tricuspid valve repair via partial sternotomy for traumatic valve insufficiency

2021 ◽  
pp. 021849232110100
Author(s):  
Motohiro Maeda ◽  
Jiro Honda ◽  
Yosuke Ishi

Tricuspid valve insufficiency rarely follows a blunt chest trauma. When the tricuspid valve is solely injured, the cardiac trauma may stay asymptomatic and tolerable, which often makes it difficult to determine the indication for surgery. We report a case of a patient with tricuspid regurgitation secondary to trauma due to a motorcycle accident. The patient was initially asymptomatic, but shortness of breath emerged two years after the accident. He underwent the tricuspid valve repair with chordae reconstruction and annuloplasty via lower partial sternotomy. We advocate that early surgical intervention prevents right heart failure, atrial fibrillation, and valve replacement.

Author(s):  
Tamas Ruttkay ◽  
Julia Götte ◽  
Ulrike Walle ◽  
Nicolas Doll

We describe a minimally invasive heart surgery application of the EinsteinVision 2.0 3D high-definition endoscopic system (Aesculap AG, Tuttlingen, Germany) in an 81-year-old man with severe tricuspid valve insufficiency. Fourteen years ago, he underwent a Ross procedure followed by a DDD pacemaker implantation 4 years later for tachy-brady-syndrome. His biventricular function was normal. We recommended minimally invasive tricuspid valve repair. The application of the aformentioned endoscopic system was simple, and the impressive 3D depth view offered an easy and precise manipulation through a minimal thoracotomy incision, avoiding the need for a rib spreading retractor.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Terézia B. Andrási ◽  
Nunijiati Abudureheman ◽  
Alannah Glück ◽  
Maximilian Vondran ◽  
Gerhard Dinges ◽  
...  

Abstract Background The timing for heart surgery following cerebral embolization after cardiac valve vegetation is vital to postoperative recovery being uneventful, additionally Covid-19 may negatively affect the outcome. Minimally invasive methods and upgraded surgical instruments maximize the benefits of surgery also in complex cardiac revision cases with substantial perioperative risk. Case presentation A 68 y.o. patient, 10 years after previous sternotomy for OPCAB was referred to cardiac surgery on the 10th postoperative day after neurosurgical intervention for intracerebral bleeding with suspected mitral valve endocarditis. Mitral valve vegetation, tricuspid valve insufficiency and coronary stenosis were diagnosed and treated by minimally invasive revision cardiac surgery on the 14th postoperative day after neurosurgery. Conclusion The present clinical case demonstrates for the first time that the minimally invasive approach via right anterior mini-thoracotomy can be safely used for concomitant complex mitral valve reconstruction, tricuspid valve repair and aorto-coronary bypass surgery, even as a revision procedure in the presence of florid endocarditis after recent neurosurgical intervention. The Covid-19 pandemic and prophylactic patient isolation slow down the efficacy of pulmonary weaning and mobilisation and prolong the need for ICU treatment, without adversely affecting long-term outcome.


2013 ◽  
Vol 32 (4) ◽  
pp. S55-S56
Author(s):  
L.E. Rodriguez ◽  
B.A. Bruckner ◽  
T. Motomura ◽  
J.D. Estep ◽  
B. Trachtenberg ◽  
...  

2021 ◽  
Author(s):  
Terezia B. Andrasi ◽  
Nunijiati Abudureheman ◽  
Alannah Glück ◽  
Maximillian Vondran ◽  
Ildar Talipov ◽  
...  

Abstract Background: The timing for heart surgery following cerebral embolization after cardiac valve vegetation is vital to postoperative recovery being uneventful, additionally Covid-19 may negatively affect the outcome. Minimally invasive methods and upgraded surgical instruments maximize the benefits of surgery also in complex cardiac revision cases with substantial perioperative risk. Case Presentation: A 68 y.o. patient, 10 years after previous sternotomy for OPCAB was referred to cardiac surgery on the 10th postoperative day after neurosurgical intervention with suspected mitral valve endocarditis. Mitral valve vegetation, tricuspid valve insufficiency and coronary stenosis were diagnosed and treated by minimally invasive revision cardiac surgery. Conclusion: The present clinical case demonstrates for the first time that the minimally invasive approach via right anterior mini-thoracotomy can be safely used for concomitant complex mitral valve reconstruction, tricuspid valve repair and aorto-coronary bypass surgery, even as a revision procedure in the presence of florid endocarditis after recent neurosurgical intervention. The Covid-19 pandemic and prophylactic patient isolation slow down the efficacy of pulmonary weaning and mobilisation and prolong the need for ICU treatment, without adversely affecting long-term outcome.


2011 ◽  
Vol 1 (1) ◽  
pp. 20
Author(s):  
Thomas Schroeter ◽  
Nicolas Doll ◽  
Sreekumar Subramanian ◽  
Friedrich W. Mohr ◽  
Michael A. Borger

Severe tricuspid valve insufficiency causes right atrial dilatation, venous congestion, and reduced atrial contractility, and may eventually lead to right heart failure. We report a case of a patient with severe tricuspid valve insufficiency, right heart failure, and a massively dilated right atrium. The enormously dilated atrium compressed the right lung, resulting in a radiographic appearance of a mediastinal tumor. Tricuspid valve repair and reduction of the right atrium was performed. Follow up examination revealed improvement of liver function, reduced peripheral edema and improved New York Heart Association (NYHA) class. The reduction of the atrial size and repair of the tricuspid valve resulted in a restoration of the conduit and reservoir function of the right atrium. Given the chronicity of the disease process and the long-standing atrial fibrillation, there is no impact of this operation on right atrial contraction. In combination with the reconstruction of the tricuspid valve, the reduction atrioplasty will reduce the risk of thrombembolic events and preserve the right ventricular function.


2018 ◽  
Vol 2 (6) ◽  
pp. 567-568
Author(s):  
Rodrigo Estévez-Loureiro ◽  
Vanessa Moñivas ◽  
Jorge Toquero ◽  
Juan Francisco Oteo ◽  
Javier Segovia ◽  
...  

Author(s):  
Muhammed Gerçek ◽  
René Schramm ◽  
Lech Paluszkiewicz ◽  
Tanja Katharina Rudolph

Abstract Background Severely reduced right heart function and high operative risk are major challenges in the treatment of tricuspid regurgitation (TR) as both can lead to low cardiac output heart failure (LCO-Hf). Alternative methods and criteria for patient selection are actively being sought. Case summary We report on a 66-year-old patient with severe right heart failure (rHF) with recurrent TR after prior surgical valve repair with a 32-mm-Edwards-MC3 annuloplasty ring (AR). Surgical revision was discarded due to extreme high surgical risk. A right ventricular assist device was discussed but declined by the patient. Percutaneous edge-to-edge repair was not applicable due to massive tethering of the anterior leaflet and complete lack of coadaptation. According to the Heart team decision, percutaneous tricuspid valve-in-ring implantation was performed using a 29-mm Sapien-3 prosthesis (SP3) under moderate balloon overinflation. Despite satisfying positioning, the prosthesis showed massive intravalvular regurgitation due to immobility of the septally oriented cusp, which was most likely caused by eccentric bulging of the prosthesis in the opening region of the AR. Implantation of a second prosthesis leads to a perfectly functional result. Importantly, no major haemodynamic complications ensued. Discussion Although being a potential risk of tricuspid valve repair LCO-hf could not be observed in the present case. Additionally, deformation of the implanted transcatheter aortic valve replacement prosthesis resulting from the regional lack of abutment in AR should be considered as a potential complication. Hence, further careful evaluation of the feasibility of percutaneous tricuspid valve treatment, also in patients with rHF, is needed.


Sign in / Sign up

Export Citation Format

Share Document