Capsular closure outweighs head size in preventing dislocation following revision total hip arthroplasty

2019 ◽  
Vol 30 (2) ◽  
pp. 141-146
Author(s):  
Christopher Pedneault ◽  
Dylan Tanzer ◽  
Anas Nooh ◽  
Karen Smith ◽  
Michael Tanzer

Introduction:The high dislocation rate following revision total hip arthroplasty (THA) has been shown to be significantly reduced by closing the posterior capsule and by the use of large diameter femoral heads. The relative importance of each of these strategies on the rate of dislocation remains unknown. We undertook a study to determine if increasing femoral head diameter, in addition to posterior capsular closure would influence the dislocation rate following revision THA.Methods:We retrospectively reviewed 144 patients who underwent a revision THA. We included all patients who underwent revision THA with closure of the posterior capsule and who had at least a 2-year minimum follow-up. 48 patients had a 28-mm femoral head, 47 had a 32-mm head and 49 patients had a 36-mm femoral head.Results:At a minimum follow-up of 2 years, there were 3 dislocations. There were no dislocations in the 28-mm group (0%), 2 in the 32-mm group (4%) and 1 in the 36-mm group (2%). Head size alone was not found to significantly decrease the risk of dislocation (28-mm versus 32-mm p = 0.12; 28-mm versus 36-mm p = 0.27; 32-mm versus 36-mm p = 0.40).Conclusion:Both large diameter heads and careful attention to surgical technique with posterior capsular closure can decrease the historically high dislocation rate after revision THA when utilising the posterolateral approach. Capsular closure outweighs the effect of femoral head diameter in preventing dislocation following revision THA through a posterolateral approach.

2019 ◽  
pp. 112070001987361 ◽  
Author(s):  
Jesús Moreta ◽  
Iker Uriarte ◽  
Xabier Foruria ◽  
Ioar Urra ◽  
Urko Aguirre ◽  
...  

Background: Cementation of polyethylene liners into well-fixed cementless metal shells has become an option during revision total hip arthroplasty (THA). We report the results of cementing a dual-mobility (DM) component into a stable acetabular shell in high-risk patients undergoing revision THA. Methods: A single-centre series of 10 patients undergoing revision THA with a DM cup cemented into an existing well-fixed shell between 2012 and 2016 were retrospectively reviewed. Failure due to aseptic loosening or instability and implant survival at last follow-up were analysed. The average age was 79.2 years and mean follow-up was 3.5 years. Indications were recurrent hip dislocation in 8 cases and intraoperative instability with moderate abductor insufficiency in 2 cases. In cases with recurrent dislocation, the aetiology of instability was classified by Wera type. Results: At the latest follow-up, Harris Hip Scores had improved from 49.3 preoperatively to 71.3 postoperatively ( p = 0.098). In the 8 patients with recurrent dislocation, 4 cases (50%) had an unclear aetiology (Wera type 6), 2 (25%) abductor deficiency (Wera type 3) and 2 (25%) late polyethylene wear (type 5). Postoperative recurrent dislocation occurred in 1 hip (10%). No cases of intraprosthetic dislocation, aseptic loosening of the previous shell or dissociation at the cement-cup interface were identified. Conclusion: Although the follow-up of this series is short, cementation of a DM cup into a previous well-fixed socket seems to be a viable option to treat and prevent instability after revision THA, without providing constraint at the cement-cup interface.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Mitsuyoshi Yamamura ◽  
Nobuo Nakamura ◽  
Hidenobu Miki ◽  
Takashi Nishii ◽  
Nobuhiko Sugano

Introduction. The perforation and fracture of the femur during the removal of bone cement in revision total hip arthroplasty (THA) are serious complications. The ROBODOC system has been designed to selectively remove bone cement from the femoral canal, but results have not been reported yet. The purpose of our study was to evaluate the clinical and radiographic results of revision THA using the ROBODOC system for cement removal.Materials and Methods. The subjects comprised 19 patients who underwent revision THA using the ROBODOC system. The minimum duration of follow-up was 76 months (median, 109 months; range, 76–150 months). The extent of remaining bone cement on postoperative radiography, timing of weight bearing, and the complications were evaluated.Results. The mean Merle d’Aubigne and Postel score increased from 10 points preoperatively to 14 points by final follow-up. Bone cement was completely removed in all cases. Full weight bearing was possible within 1 week after surgery in 9 of the 19 cases and within 2 months in all remaining cases. No instances of perforation or fracture of the femur were encountered.Conclusions. Bone cement could be safely removed using the ROBODOC system, and no serious complications occurred. Full weight bearing was achieved early in the postoperative course because of circumferential preservation of the femoral cortex.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Hou-Tsung Chen ◽  
Cheng-Ta Wu ◽  
Tsan-Wen Huang ◽  
Hsin-Nung Shih ◽  
Jun-Wen Wang ◽  
...  

Using morselized and structural allograft to restore bone stock for massive acetabular bone defect in revision total hip arthroplasty (THA) is an appealing procedure. However, concerns about inability to achieve long-term stability following allograft resorption remained. From 2003 to 2012, 59 hips in 58 patients undergoing revision THA for Paprosky type II or III acetabular defects were retrospectively reviewed. The acetabular defects were managed with deep-frozen morselized and structural allografts, and a press-fit cementless cup along with supplementary screws. Clinical outcomes and radiographic results were analyzed with a mean follow-up of 8.7 years. The clinical successful rate was 100% for hips with Paprosky type II defect, 95.2% for IIIA defect, and 92.8% for IIIB defect. Three hips with type III defect failed at 4, 7, and 9 years, respectively. Harris Hip Score improved significantly from 60.1 preoperatively to 91.3 at the latest follow-up. All hips with good clinical results showed trabecular bridging in the allograft-host bone interface. Deep-frozen structural and morselized allograft in combination with a press-fit cementless cup represented a viable option to reconstruct acetabular defects in revision THA.


2020 ◽  
Vol 30 (1_suppl) ◽  
pp. 7-11
Author(s):  
Massimo Franceschini ◽  
N Amir Sandiford ◽  
Vincenzo Cerbone ◽  
Lucio Cappelli Toledo de Araujo ◽  
Daniel Kendoff

Background: Infections remains the most feared complication in total hip arthroplasty (THA). New strategies of PJI prevention includes coating of conventional implants. Defensive Antibacterial Coating (DAC), an antibacterial hydrogel coating made of hyaluronan, poly-D and L-lactide can protect biomaterials as an effective barrier at the time of implantation. In addition, it can be used with topical antibiotics to prevent early colonisation of the implant. Scope: This manuscript describes the detailed function of the DAC in general as well as an analysis of its use in revision THA in a series of 28 patients in a short-term follow-up. Its use in patients undergoing cementless re-implantation after 2-staged procedures in THA is described in detail within the manuscript. Conclusion: DAC found to be effective in terms of infection control and safety in our patient cohort and has been expanded for cementless 1-staged revisions in PJI of the hip in our institution.


2021 ◽  
Vol 103-B (7 Supple B) ◽  
pp. 66-72
Author(s):  
Nicholas M. Hernandez ◽  
Zoe W. Hinton ◽  
Christine J. Wu ◽  
Paul F. Lachiewicz ◽  
Sean P. Ryan ◽  
...  

Aims Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. Methods Using the database of a single academic centre, 126 revision THAs in 117 patients using a single design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome. Results The overall rate of dislocation was 11%, with a six-year survival of 91%. Reoperation for dislocation was performed in seven patients (7%), with a six-year survival of 94%. The dislocations were early (at a mean of 33 days) in six patients, and late (at a mean of 4.3 years) in four patients. There were three intraprosthetic dissociations. An outer head diameter of ≥ 48 mm was associated with a lower risk of dislocation (p = 0.013). Lumbrosacral fusion was associated with increased dislocation (p = 0.004). Four revision THAs (4%) were further revised for aseptic acetabular loosening, and severe bone loss (Paprosky III) at the time of the initial revision was significantly associated with further revision for aseptic acetabular loosening (p = 0.008). Fourteen acetabular components (15%) were re-revised for infection, and a pre-revision diagnosis of reimplantation after periprosthetic joint infection (PJI) was associated with subsequent PJI (p < 0.001). Two THAs had visible metallic changes on the backside of the cobalt chromium liner. Conclusion When using this MDM component in revision THA, at a mean follow-up of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. The size of the outer bearing was related to the risk of dislocation. There was a low rate of aseptic acetabular loosening. Longer follow-up of this MDM component and evaluation of other designs are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):66–72.


Sign in / Sign up

Export Citation Format

Share Document