Modifying the “Eye of the Tiger” Technique: Preserving Gluteal Artery Perfusion in the Treatment of an Aneurysm of the Hypogastric Artery

2020 ◽  
pp. 153857442096610
Author(s):  
Shinichi Iwakoshi ◽  
Masahiro Inagaki ◽  
Yutaka Yoshiyama ◽  
Yuichi Shimohara ◽  
Masanori Yamashita ◽  
...  

Purpose: In endovascular aneurysm repair, parallel stent graft deployment is sometimes utilized to preserve the distal branch perfusion. However, there will be some gutter space around 2 stent grafts, which may cause endoleak. The “eye of the tiger” technique was invented to minimize this leak when deploying a small side-branch stent graft in conjunction with a large aortic endograft. The purpose of this case report is to describe our modified technique for 2 small endografts deployed in double D-shape in order to prevent gutter leak, which we applied in endovascular treatment for a hypogastric artery aneurysm. Case Report: A 79-year-old male patient presented with a right hypogastric artery aneurysm measuring 44 mm. The patient refused the open surgical repair option and hoped for an endovascular treatment. Therefore, endovascular treatment to exclude the hypogastric artery aneurysm as well as preserve the gluteal arteries was planned. An Internal Iliac Component (IIC)(W. L. Gore & Associates, Flagstaff, AZ, USA) was utilized for the proximal sealing and 2 Viabahn stent grafts (W. L. Gore & Associates) were deployed in the superior and inferior gluteal arteries for distal sealing. Then, 2 VBX stent grafts (W. L. Gore & Associates) were added in the IIC as bridging stents to connect the IIC and both Viabahn stent grafts. Next, over-dilatation of VBX stent grafts was performed alternately with an 8 mm balloon catheter and subsequent kissing balloon dilation with 5 mm balloon catheters, which allowed the VBX stents to be set in double D-shape. A follow-up CT scan performed 1 week after the procedure revealed no endoleak and a favorable shape to the VBX stent grafts. Conclusion: The modified method of dilating the VBX stent grafts allowed the double D-shape deployment, minimizing the risk of gutter leak and preserving distal branch perfusion.

2006 ◽  
Vol 20 (1) ◽  
pp. 134-137 ◽  
Author(s):  
Kambiz Jacob Cohen-Kashi ◽  
Nirupama Anne ◽  
Ratna Kishore Pallapothu ◽  
Lawrence Scher

2005 ◽  
Vol 52 (2) ◽  
pp. 107
Author(s):  
Jeong Yeol Choi ◽  
Dong Hyun Kim ◽  
Hyung Woo Oh ◽  
Jeong Hwan Jang ◽  
Jae Hee Oh ◽  
...  

2021 ◽  
Vol 9 ◽  
pp. 2050313X2098734
Author(s):  
Yuki Takara ◽  
Daisuke Yunaiyama ◽  
Toru Saguchi ◽  
Natsuhiko Shirota ◽  
Takafumi Yamada ◽  
...  

The dorsal pancreatic artery is a part of peripancreatic arcade connecting celiac artery to transpancreatic artery. A dorsal pancreatic artery aneurysm derived from dissection of celiac artery is a rare pathology, and it sometimes requires ingenious strategy in an endovascular surgery. Hereby, we report a case of a patient who underwent coil embolization for dorsal pancreatic artery aneurysm due to celiac artery dissection by applying transcirculation approach of a balloon catheter through the peripancreatic arcade, which was successfully achieved.


2020 ◽  
Author(s):  
Hideyuki Torikai ◽  
Masanori Inoue ◽  
Nobutake Ito ◽  
Seishi Nakatsuka ◽  
Masashi Tamura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document