stent graft repair
Recently Published Documents


TOTAL DOCUMENTS

399
(FIVE YEARS 29)

H-INDEX

41
(FIVE YEARS 2)

Vascular ◽  
2021 ◽  
pp. 170853812110451
Author(s):  
Marco Franchin ◽  
Federico Fontana ◽  
Luca Luzzani ◽  
Michela Lanza ◽  
Gabriele Piffaretti ◽  
...  

Objective This study aims to report a case series of anastomotic femoral pseudoaneurysms (PSA) treated with stent-grafting (SG) in patients at high-risk for the open surgical approach. Methods It is a retrospective, observational cohort study. Between 1 January 2002 and 1 April 2020, post-hoc analysis of the database including patients who received repair for femoral PSA identified those treated with SG. All but one patient were approached through a contralateral percutaneous transfemoral access, and the SG was always deployed from the common femoral artery to the profunda femoris artery. For this study, primary outcomes of interest were early (≤ 30 days) survival and patency rate. Results We identified 10/823 cases of the entire PSA cohort (1.2%). There were 9 men and 1 woman: the mean age was 76 years ± 9 (range: 64–92). Urgent intervention was performed in 4 patients. The median operative time was 30 min (IQR: 25–36). Access-related complication was never observed. In-hospital mortality occurred in 1 patient due to novel coronavirus-19–related pneumonia. Median follow-up was 24 months (IQR: 12–37); 5 patients died. At the last radiologic follow-up available, all SGs were patent without necessity of reintervention. Conclusion Stent-graft repair for anastomotic femoral PSA may be considered a reasonable alternative for patients at high-risk for open surgical repair.


Author(s):  
Sven R. Hauck ◽  
Alexander Kupferthaler ◽  
Marlies Stelzmüller ◽  
Wolf Eilenberg ◽  
Marek Ehrlich ◽  
...  

Abstract Purpose To test a stent-graft specifically designed for the ascending aorta in phantom, cadaver, and clinical application, and to measure deployment accuracy to overcome limitations of existing devices. Methods A stent-graft has been designed with support wires to fixate the apices toward the inner curvature, thereby eliminating the forward movement of the proximal end which can happen with circumferential tip capture systems. The device was deployed in three aortic phantoms, and in four cadavers, deployment precision was measured. Subsequently, the device was implanted in a patient to exclude a pseudoaneurysm originating from the distal anastomosis after ascending aortic replacement. Results The stent-grafts were successfully deployed in all phantoms and cadavers. Deployment accuracy of the proximal end of the stent-graft was within 1 mm proximally and 14 mm distally to the intended landing zone on the inner curvature, and 2–8 mm distal to the intended landing zone on the outer curvature. In clinical application, the pseudoaneurysm could be successfully excluded without complications. Conclusion The novel stent-graft design promises accurate placement in the ascending aorta. The differential deployment of the apices at the inner and outer curvatures allows deployment perpendicular to the aortic axis. Level of Evidence No level of evidence.


Vascular ◽  
2021 ◽  
pp. 170853812110136
Author(s):  
Wael E Shaalan ◽  
Ali A El Emam ◽  
Hassan I Lotfy ◽  
Ahmad R Naga

Objectives Behcet’s disease is a multisystem disorder of unknown etiology with vascular complications. This study reviewed the mid-term outcome of Behcet’s disease patients with carotid artery pseudo-aneurysms treated by endovascular stent-graft repair at our unit. Methods During a period of 11 years, six cases were included. Postoperative ultrasound duplex results were recorded along with computed tomography angiography report done a year after intervention. Results The mean age (±SD) was 38 (±5.2) years. The mean (±SD) pseudo-aneurysm size was 33 (±12.2) mm. Technical success was 83%; failed cannulation of the internal carotid artery was encountered in one case. On day 2 post-operative, a duplex ultrasound revealed complete exclusion and thrombosis of the false aneurysm in all cases. A year later, a computed tomography angiography revealed a primary patency rate of 80%, and only one case had a recurrent pseudo-aneurysm at the distal margin of the stent graft. All cases, however, had complete thrombosis in the pseudo-aneurysms lumen with a mean (±SD) regression in size of 18 (±6) mm. The mean (±SD) percentage of in-stent stenosis was 34.5% (±11.73%). Conclusions Stent graft repair for carotid artery pseudo-aneurysm in Behcet’s disease patients might be the preferable first line of treatment since it had a high technical success and mid-term primary patency rates, with additional fact that it obviously avoids the hazardous complications of surgery.


2021 ◽  
Vol 20 ◽  
Author(s):  
Ricardo de Alvarenga Yoshida ◽  
Renato Fanchiotti Costa ◽  
Débora Ortigosa Cunha ◽  
Rafael Mendes Palhares ◽  
Rodrigo Gibin Jaldin ◽  
...  

Abstract Background Surgical management of patients with abdominal aortic diseases associated with distal narrowing is a challenging situation. Objectives To evaluate outcomes of unibody bifurcated endovascular stent graft repair. Methods This is a retrospective, observational, multi-institutional database study of a cohort of consecutive cases, approved by the local Ethics Committee. Records were reviewed of patients diagnosed from 2010 to 2020 with “shaggy” aorta, saccular aneurysm, penetrating aortic ulcer, and isolated aortic dissection located in the infrarenal abdominal aorta. All patients were treated with a unibody bifurcated stent graft. Main outcomes were technical success, procedure complications, long-term patency, and mortality in the follow-up period up to 5 years. Data on demographics, comorbidities, surgical management, and outcomes were analyzed. Results Twenty-three patients were treated with unibody bifurcated stent graft repair, including 7 cases of “shaggy” aorta, 3 isolated dissections of the abdominal aorta, 4 penetrating aortic ulcers, and 9 saccular aneurysms. Immediate technical success was achieved in 100% of cases. At follow-up, all stent grafts remained patent and there were no limb occlusions. The patients were symptom-free and reported no complications related to the procedure. There were 5 deaths during the follow-up period (median= 4 years), but none were related to the procedure and there were no aorta-related deaths. Conclusions The present study shows that unibody bifurcated stent grafting is safe and effective in this group of patients with narrow distal abdominal aorta and complex aortic pathology. The results were similar for both infrarenal aortic aneurysms and aorto-iliac atherosclerotic disease.


Sign in / Sign up

Export Citation Format

Share Document