Topographical Analysis of the Onset VEP in the Detection of Paracentral Visual Field Defects

2002 ◽  
Vol 33 (2) ◽  
pp. 62-69 ◽  
Author(s):  
Ferdinando Sartucci ◽  
Michele Tagliati ◽  
Leland H. Mylin ◽  
Ivan Bodis-Wollner

Transient visual evoked potentials (VEP) were recorded simultaneously from 16 electrodes evenly placed over posterior scalp locations covering the occipital, posterior parietal and temporal areas. Interhemispheric amplitude difference of the N70 deflection was established across 6 homologous lateral electrode pairs in 15 normal controls and 32 patients with chiasmatic or retrochiasmatic cerebral lesions. Twenty-three of these had known homonymous or bitemporal field defects while 9 had normal fields on routine perimetry. Significant interhemispheric asymmetry of any single electrode pair occurred in 55% of the 32 patients with known pathology, while the cumulative yield of all electrode pairs was over 80 percent. The diagnostic yield of individual electrode pairs was significantly different: the electrode pair placed over the temporo-parietal junction detected the highest number of abnormalities. The cumulative abnormality taken over all lateral electrode pairs could be described with a curve well fitted with a probability summation function. It is inferred that the contribution of several independent generator sources is reflected in the N70 of the pattern onset VEP. The results suggest that multichannel recording of the interhemispheric amplitude distribution of the N70 of the onset VEP is useful for the evaluation of paracentral visual field defects.

2021 ◽  
Vol 223 ◽  
pp. 229-240
Author(s):  
Eren Ekici ◽  
Sasan Moghimi ◽  
Huiyuan Hou ◽  
James Proudfoot ◽  
Linda M. Zangwill ◽  
...  

1998 ◽  
Vol 4 (2) ◽  
pp. 79-84 ◽  
Author(s):  
N Accornero ◽  
S Rinalduzzi ◽  
M Capozza ◽  
E Millefiorini ◽  
G C Filligoi ◽  
...  

Color visual field analysis has proven highly sensitive for early visual impairments diagnosis in MS, yet it has never attained widespread popularity usually because the procedure is difficult to standardize, the devices are costly, and the test is fatiguing. We propose a computerized procedure running on standard PC, cost effective, clonable, and easy handled. Two hundred and sixty-four colored patches subtending 18 angle of vision, with selected hues and low saturation levels are sequentially and randomly displayed on gray equiluminous background of the PC screen subtending 2486408 angle of vision. The subject is requested to press a switch at the perception of the stimulus. The output provides colored maps with quantitative information. Comparison between normals and a selected population of MS patients with no actual luminance visual field defects, showed high statistical difference.


Ophthalmology ◽  
2017 ◽  
Vol 124 (11) ◽  
pp. 1600-1611 ◽  
Author(s):  
Yu Sawada ◽  
Makoto Araie ◽  
Makoto Ishikawa ◽  
Takeshi Yoshitomi

1992 ◽  
Vol 7 (2) ◽  
pp. 130-146 ◽  
Author(s):  
Mario Zulauf ◽  
Joseph Caprioli

Neurology ◽  
1999 ◽  
Vol 53 (5) ◽  
pp. 922-922 ◽  
Author(s):  
R. Kalviainen ◽  
I. Nousiainen ◽  
M. Mantyjarvi ◽  
E. Nikoskelainen ◽  
J. Partanen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document