Sutureless Aortic Valve Replacement in the Setting of Triple-Valve Surgery

Author(s):  
Amine Mazine ◽  
Nicola Vistarini ◽  
Ismail El-Hamamsy ◽  
Michel Carrier ◽  
Denis Bouchard ◽  
...  
Author(s):  
Amine Mazine ◽  
Nicola Vistarini ◽  
Ismail El-Hamamsy ◽  
Michel Carrier ◽  
Denis Bouchard ◽  
...  

Sutureless aortic valve replacement is an emerging alternative to standard aortic valve replacement in high-risk surgical patients. We present our surgical technique for sutureless aortic valve replacement in patients undergoing triple-valve surgery. This procedure has been performed in six patients with excellent clinical and echocardiographic results. Despite some technical concerns, sutureless aortic valve replacement in the setting of triple-valve surgery is simple and reproducible.


2019 ◽  
Vol 30 (3) ◽  
pp. 424-430 ◽  
Author(s):  
Masayoshi Tokoro ◽  
Sadanari Sawaki ◽  
Takahiro Ozeki ◽  
Mamoru Orii ◽  
Akihiko Usui ◽  
...  

Abstract OBJECTIVES Totally endoscopic aortic valve replacement (AVR) is still a challenging operation, and only a few series reports exist in the literature. The purposes of this study were to establish a method for endoscopic AVR and evaluate its initial results. METHODS A total of 47 patients (median age 76 years, 17 men) underwent endoscopic AVR. The main wound was created in the right anterolateral 4th intercostal space through a 4-cm skin incision. No rib spreader was used. A 3-dimensional endoscope was inserted at the midaxillary line. A 5.5-mm trocar was inserted in the 3rd intercostal space, thus creating a 3-port setting similar to that used for endoscopic mitral valve surgery. A standard prosthesis was used, and the sutures were tied using a knot pusher. Results were compared with those of 157 patients who underwent right transaxillary AVR with direct vision plus endoscopic assist. RESULTS Patient backgrounds did not differ significantly between the 2 groups. No deaths occurred in the entire series. There was no conversion to thoracotomy or sternotomy in the endoscopic AVR group. The complication rate did not differ significantly between the 2 groups. The total operating time was significantly shorter in endoscopic AVR (188–206 min); the cardiopulmonary bypass time (130–128 min) and the cross-clamp time (90–95 min) did not differ significantly (median, endoscopic AVR, right transaxillary AVR). Two patients underwent endoscopic double-valve (aortic and mitral) surgery under the same conditions. CONCLUSIONS Endoscopic AVR was possible through 3 ports created in the right anterolateral chest, similar to the procedure for endoscopic mitral valve surgery. By adopting a common approach for both the aortic and the mitral valve operations, endoscopic double-valve surgery can be performed seamlessly.


1996 ◽  
Vol 66 (12) ◽  
pp. 799-805 ◽  
Author(s):  
Justin R. Bessell ◽  
Georgina Gower ◽  
David R. Craddock ◽  
John Stubberfield ◽  
Guy J. Maddern

Author(s):  
Nnamdi Nwaejike ◽  
Christopher Rozario ◽  
Franco Sogliani

We describe the successful management of a stent protruding from the right coronary ostium into the aortic root in the setting of aortic valve replacement for aortic stenosis. Due to advances in medical care more elderly patients present for aortic valve surgery after percutaneous coronary intervention. Therefore, with an aging population due to advances in medical care, more patients will present for aortic valve surgery after percutaneous coronary intervention. We suggest a degree of caution before valve deployment in transcatheter aortic valve intervention or during annular manipulation in patients undergoing traditional aortic valve replacement with coexisting patent proximal stents.


Author(s):  
Marlena Sabatino ◽  
NaYoung Yang ◽  
Fady Soliman ◽  
Joshua Chao ◽  
ALEXIS OKOH ◽  
...  

Background: Minimally invasive heart valve surgery has previously been shown to be safe and feasible in obese patients. Within this population, we investigated the effect of obesity class on the patient outcomes of minimally invasive aortic valve replacement (mini-AVR). Methods: A single center retrospective cohort study of consecutive patients with obese body mass indices (BMIs) who underwent mini-AVR between 2012 and 2018. Patients were stratified into 3 groups according to Centers for Disease Control and Prevention adult obesity classifications: Class I (BMI 30.0 to < 35.0), Class II (BMI 35.0 to < 40.0), and Class III (BMI ≥ 40.0). The primary outcomes were postoperative length of stay (LOS), 30-day mortality within, and cost. Results: Amongst 182 obese patients who underwent mini-AVR, LOS (Class I 4 [3-6] vs. Class II 4 [3-6] vs. Class III 5 [4-6] days; p=0.098) and costs (Class I $24,487 [$20,199-$27.480] vs. Class II $22,921 [$20,433-$27,740] vs. Class III $23,886 [$20,063-$33,800] USD; p=0.860) did not differ between obesity class cohorts. Postoperative 30-day mortality (Class I 2.83% [n=2] vs. Class II 0% [n=0] vs. Class III 0% [n=0]; p=0.763) was limited by an insufficient sample size relative to a low event rate but did not differ between patient cohorts. Conclusions: Mini-AVR is safe and feasible to perform for obese patients regardless of their obesity class. Patients with obesity should be afforded the option of minimally invasive aortic valve surgery regardless of their obesity class.


Sign in / Sign up

Export Citation Format

Share Document