Pre-Embolization Study of Ruptured Cerebral Aneurysms with Helical CT

1999 ◽  
Vol 5 (1_suppl) ◽  
pp. 219-223 ◽  
Author(s):  
M. Nomura ◽  
S. Kida ◽  
N. Uchiyama ◽  
T. Yamashima ◽  
J. Yamashita ◽  
...  

Sixteen ruptured aneurysms in 16 patients considered endovascular embolizations were examined. The findings of axial source images (axial images) and reconstructed three-dimensional CT angiography (3D-CTA) of helical CT were compared to those of rotational digital subtraction angiography (DSA). The aneurysmal neck and arterial branches adjacent to the neck were closely investigated. In seven out of 16 cases (43.8%), information provided by axial images and/or 3D-CTA was more useful than that of rotational DSA in evaluating the aneurysmal neck and arterial branches. Helical CT can provide valuable information on ruptured aneurysms that cannot be obtained by rotational DSA in some patients. This technique is useful to obtain anatomical information about aneurysms and to select the best therapeutic method.

2005 ◽  
Vol 57 (suppl_1) ◽  
pp. 69-77 ◽  
Author(s):  
Lucia Benvenuti ◽  
Salvatore Chibbaro ◽  
Stefano Carnesecchi ◽  
Flavio Pulerà ◽  
Rolando Gagliardi

Abstract OBJECTIVE: To introduce the possibility of volume-rendered helical computed tomographic (CT) angiographic data sets by use of Medtronic StealthStation Treon surgical navigation technology (Medtronic Surgical Navigation Technologies, Louisville, CO) and to evaluate the clinical usefulness of the method in planning and performing surgical treatment of intracranial aneurysms. METHODS: Between November 2002 and July 2003, we studied 15 patients with suspected intracranial aneurysms. All patients but two received conventional digital subtraction angiography, which failed to provide the requested information. Helical CT angiography was performed in all patients, and data sets were transferred to the StealthStation system across an electronic network to be automatically postprocessed by use of three-dimensional (3-D) volume rendering. The 3-D volume-rendered images were accurately analyzed to obtain more complete information about the aneurysm and to provide accurate treatment planning. In all patients, the 3-D volume-rendered model was displayed on the screen of the StealthStation system for the duration of the surgical procedure and compared with the intraoperative image. RESULTS: Data sets from CT angiography were automatically postprocessed by the StealthStation in seconds with excellent results, providing us, before and during surgery, with additional information not always available on traditional digital subtraction angiographic investigation. Because of the very short time necessary to complete this process (<5 min to obtain 3-D volume-rendered images), it was possible to perform emergency clipping of the aneurysms in two patients who had been admitted in very compromised neurological conditions. In 12 patients, integrated digital subtraction angiography and automated 3-D volume-rendered images allowed an accurate presurgical evaluation. Furthermore, in all patients on whom surgery was performed, aneurysms were found in the exact location and with the same anatomic features as depicted by the 3-D volume-rendered models. CONCLUSION: Reports in the literature indicate that information gathered by CT angiography with volume rendering shows a significant impact on aneurysm management. The StealthStation system upgraded with the adequate algorithm seems to provide a time- and cost-effective method of performing automated 3-D volume rendering of CT angiography and provides an interesting alternative to the available investigation modalities in case of emergency.


2020 ◽  
Vol 26 (6) ◽  
pp. 733-740
Author(s):  
Te-Chang Wu ◽  
Yu-Kun Tsui ◽  
Tai-Yuan Chen ◽  
Ching-Chung Ko ◽  
Chien-Jen Lin ◽  
...  

Background To investigate the discrepancy between two-dimensional digital subtraction angiography and three-dimensional rotational angiography for small (<5 mm) cerebral aneurysms and the impact on decision making among neuro-interventional experts as evaluated by online questionnaire. Materials and methods Eight small (<5 mm) ruptured aneurysms were visually identified in 16 image sets in either two-dimensional or three-dimensional format for placement in a questionnaire for 11 invited neuro-interventionalists. For each set, two questions were posed: Question 1: “Which of the following is the preferred treatment choice: simple coiling, balloon remodeling or stent assisted coiling?”; Question 2: “Is it achievable to secure the aneurysm with pure simple coiling?” The discrepancies of angio-architecture parameters and treatment choices between two-dimensional-digital subtraction angiography and three-dimensional rotational angiography were evaluated. Results In all eight cases, the neck images via three-dimensional rotational angiography were larger than two-dimensional-digital subtraction angiography with a mean difference of 0.95 mm. All eight cases analyzed with three-dimensional rotational angiography, but only one case with two-dimensional-digital subtraction angiography were classified as wide-neck aneurysms with dome-to-neck ratio < 1.5. The treatment choices based on the two-dimensional or three-dimensional information were different in 56 of 88 (63.6%) paired answers. Simple coiling was the preferred choice in 66 (75%) and 26 (29.6%) answers based on two-dimensional and three-dimensional information, respectively. Three types of angio-architecture with a narrow gap between the aneurysm sidewall and parent artery were proposed as an explanation for neck overestimation with three-dimensional rotational angiography. Conclusions Aneurysm neck overestimation with three-dimensional rotational angiography predisposed neuro-interventionalists to more complex treatment techniques. Additional two-dimensional information is crucial for endovascular treatment planning for small cerebral aneurysms.


Radiology ◽  
2012 ◽  
Vol 262 (2) ◽  
pp. 605-612 ◽  
Author(s):  
Li Lu ◽  
Long Jiang Zhang ◽  
Colin S. Poon ◽  
Sheng Yong Wu ◽  
Chang Sheng Zhou ◽  
...  

2021 ◽  
Vol 57 (3) ◽  
pp. 260-268
Author(s):  
Darjan Franjić ◽  
Josip Mašković

Aim: To determine the value of three-dimensional (3D) digital subtraction angiography (DSA) in the detection of intracranial aneurysms and to compare 3D technique with DSA. Materials and Methods: A retrospective analysis of 50 patients with 60 intracranial aneurysms who underwent both conventional DSA and 3D-DSA for the evaluation of intracranial aneurysms was conducted. The presence of aneurysms, detection of aneurysmal neck, size, location, presence of additional and small aneurysms analyzed from the two protocols were compared. Results: Three-dimensional technique detected 54 aneurysms while conventional DSA detected 38 aneurysms. There was no correlation between aneurysm detection and aneurysm neck detection in the two technologies observed, but there was a difference in detection performance depending on the technology used. Three-dimensional technique detected 52 aneurysm necks while conventional DSA detected 24 aneurysm necks. There was a statistically significant and positive relationship between the detected size of the aneurysm using 3D technique and DSA technology. Three-dimensional technique detected 24 additional aneurysms while conventional DSA detected only six additional aneurysms. Conclusions: Three-dimensional technique are more successful in the detection of aneurysms, their necks and small aneurysms in comparison to digital subtraction angiography, but difference is not statistically significant. The size of the aneurysm statistically significant affects the aneurysm neck detection by conventional DSA.


Sign in / Sign up

Export Citation Format

Share Document