Investigation of Tissue Inhibitor of Metalloproteinases 1 in Plasma from Colorectal Cancer Patients and Blood Donors by Surface-Enhanced Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

2007 ◽  
Vol 22 (2) ◽  
pp. 89-94 ◽  
Author(s):  
M.B. Caspersen ◽  
N.M. Sørensen ◽  
A.S. Schrohl ◽  
P. Iversen ◽  
H.J. Nielsen ◽  
...  

Early detection of colorectal cancer (CRC) improves patient survival. Plasma tissue inhibitor of metalloproteinases 1 (TIMP-1) measurements by enzyme-linked immunosorbent assay (ELISA) have been suggested as a new method for the early detection of CRC. To further investigate the nature of TIMP-1 in plasma, surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI TOF MS) was used. TIMP-1 measurements of plasma from 16 healthy donors and 14 CRC patients were performed using TIMP-1 monoclonal antibody in SELDI TOF MS and ELISA. SELDI TOF MS applying an antibody to TIMP-1 revealed that human plasma TIMP-1 has a mass of 25.1 kDa and exhibits several isoforms. Both methods showed increased plasma TIMP-1 values for cancer patients as compared to healthy individuals. The p values for the separation of the groups were 0.0019 for ELISA and <0.0001 for SELDI TOF MS. CRC did not fundamentally affect the appearance of TIMP-1 as evaluated by SELDI TOF MS.

2007 ◽  
Vol 22 (2) ◽  
pp. 89-94 ◽  
Author(s):  
M.B. Caspersen ◽  
N.M. Sørensen ◽  
A.S. Schrohl ◽  
P. Iversen ◽  
H.J. Nielsen ◽  
...  

Early detection of colorectal cancer (CRC) improves patient survival. Plasma tissue inhibitor of metalloproteinases 1 (TIMP-1) measurements by enzyme-linked immunosorbent assay (ELISA) have been suggested as a new method for the early detection of CRC. To further investigate the nature of TIMP-1 in plasma, surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI TOF MS) was used. TIMP-1 measurements of plasma from 16 healthy donors and 14 CRC patients were performed using TIMP-1 monoclonal antibody in SELDI TOF MS and ELISA. SELDI TOF MS applying an antibody to TIMP-1 revealed that human plasma TIMP-1 has a mass of 25.1 kDa and exhibits several isoforms. Both methods showed increased plasma TIMP-1 values for cancer patients as compared to healthy individuals. The p values for the separation of the groups were 0.0019 for ELISA and <0.0001 for SELDI TOF MS. CRC did not fundamentally affect the appearance of TIMP-1 as evaluated by SELDI TOF MS.


2008 ◽  
Vol 86 (8) ◽  
pp. 566-570 ◽  
Author(s):  
Jens Raila ◽  
Philipp Kalk ◽  
Thiemo Pfab ◽  
Christa Thöne-Reineke ◽  
Michael Godes ◽  
...  

The pathways leading to salt-sensitive hypertension and renal damage in rescued ETB receptor-deficient (ETBRd) rats are still unknown. The objective of the study was therefore to identify modifications of urinary peptide and protein expression in ETBRd rats (n = 9) and wild-type controls (n = 6) using SDS – polyacrylamide gel electrophoresis (SDS-PAGE) and surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) technology. Glomerular filtration rate, glomerulosclerosis, and tubulointerstitial fibrosis did not differ between the groups. ETBRd rats showed slightly higher blood pressure (p < 0.001), media/lumen ratio of intrarenal arteries (p < 0.01), and albuminuria (p < 0.01). SDS-PAGE confirmed albuminuria, but showed no differences in the urinary excretion of low molecular weight proteins (<60 kDa). SELDI-TOF-MS profiling revealed 9 proteomic features at molecular masses (Da) of 2720, 2980, 3130, 3345, 6466, 6682, 8550, 18 729, and 37 492, which were significantly elevated (p < 0.02) in urine of ETBRd rats. The results demonstrate that, independent of structural changes in the kidneys, ETB-receptor deficiency causes specific differences in urinary peptide and protein excretion. SELDI-TOF-MS may be a valuable tool for the characterization of urinary biomarkers helping to uncover the mechanism of ETBR action in the kidney.


Sign in / Sign up

Export Citation Format

Share Document