scholarly journals Clinical Safety and Outcomes of a Novel Ultrasound Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries

2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0016
Author(s):  
Jie Chen ◽  
Akhil Sharma ◽  
Craig C. Akoh ◽  
Rishin J. Kadakia ◽  
Selene G. Parekh

Category: Sports Introduction/Purpose: Bioabsorbable suture anchors have been popularized due to potential for osseous integration, less interference with diagnostic imaging, and ease of use. Recently, ultrasound assisted suture anchor systems have been introduced with the benefits of obtaining interdigitation with cancellous bone while maintaining a minimal footprint. In a cadaveric study, ultrasound assisted suture anchors demonstrated a similar pullout strength and less system displacement when compared to a benchmark bioabsorbable anchor system. However, the failure and complication rates of ultrasound assisted bioabsorbable anchors has never been demonstrated in a clinical setting. We studied the Stryker SonicAnchor by examining complication rates in foot and ankle procedures and secondarily determined the efficacy by evaluating clinical outcomes of surgeries using this anchor system. Methods: A retrospective analysis was performed on all patients treated by the primary investigator using the Stryker SutureAnchor between the dates of May 2016 and February 2018. We included all patients for which the anchor was used during surgery with at least 2 year followup including VAS and FAOS scores. We recorded baseline demographic information as well as the type of surgery patients underwent. We recorded all intraoperative and postoperative complications for these surgeries. In addition, we compared preoperative and postoperative clinical scores. Results: 57 patients met inclusion criteria. On average, patients were 53 years old at the time of surgery. Mean followup was 32.8 months. Mean BMI was 30.36. Three patients reported current tobacco use (5.3%), four patients (7.0%) had type II diabetes mellitus at the time of their surgery, and only one patient (1.8%) had osteoporosis. Common procedures were Achilles repair including Haglund’s resection, peroneal surgery, and lateral ligament reconstruction. There were two deep infections requiring reoperation, one medial malleolus stress fracture following total ankle replacement, one metatarsal stress fracture not involving the surgery site, and one DVT. No reports of anchor pullout or soft tissue repair failure. VAS and FAOS scores improved from 6.2 to 1.2 and 54.3 to 93.9. Conclusion: In our review of 57 patients operated on with the SonicAnchor with at least two year followup, there were zero cases of complications stemming from the anchor including anchor pullout or soft tissue repair failure. Overall, patients improved tremendously in their clinical outcome scores across a wide range of different procedures. Previous studies have demonstrated the biomechanical strength of the SonicAnchor and our review supports its clinical safety and efficacy in long-term clinical followup.

2020 ◽  
Vol 41 (9) ◽  
pp. 1073-1078
Author(s):  
Jie Chen ◽  
Akhil Sharma ◽  
Craig Chike Akoh ◽  
Rishin Kadakia ◽  
Selene G. Parekh

Background: Suture anchors have been used for soft tissue repair in orthopedic surgery for decades. Recently, bioabsorbable suture anchors have increased in popularity and have spurred the introduction of ultrasound-assisted systems. The purpose of our study was to determine the clinical safety and efficacy of a new ultrasound-assisted suture anchor system for foot and ankle procedures. Methods: We retrospectively reviewed 50 cases using the ultrasound-assisted suture anchor with at least 24 months of follow-up. We reviewed demographic data including comorbidities, type of procedure, adverse events, and clinical outcomes using the Foot and Ankle Outcome Score (FAOS) and visual analog scale (VAS) score. We divided complications into minor and major, with major complications requiring revision surgery or leading to long-term morbidity. Our primary outcome was complication rates and our secondary outcome was improvement in clinical scores. Results: The most frequent cases using the anchor included lateral ankle ligament reconstruction ( n = 19), insertional Achilles repair ( n = 15), lateral ligament reconstruction in conjunction with a total ankle arthroplasty ( n = 6), and plantar plate repair ( n = 3). There were 5 superficial wound infections that resolved with wound care and/or oral antibiotics. There were 3 major complications (6%): a deep wound infection that required an irrigation and debridement, a deep venous thrombosis, and a recurrence of varus deformity in a patient who underwent a total ankle arthroplasty with lateral ligament reconstruction. Only the varus deformity recurrence case could possibly be directly linked to the suture anchor (2% of all cases). VAS scores improved from 6.0 to 1.2 ( P < .001) and FAOS improved from 54.7 to 94.2 ( P < .001). Conclusion: This bioabsorbable anchor was a safe device with low failure rates, and it was used for soft tissue repair cases in the foot and ankle with successful clinical outcomes. Level of Evidence: Level IV, retrospective case series.


2021 ◽  
pp. 193864002110676
Author(s):  
Michael J. Kelly ◽  
Daniel M. Dean ◽  
Syed H. Hussaini ◽  
Steven K. Neufeld ◽  
Daniel J. Cuttica

Background Augmentation of soft tissue repairs has been helpful in protecting surgically repaired tissues as they heal. FlexBand (Artelon, Marietta, Georgia) is a synthetic, degradable, polycaprolactone-based polyurethane urea (PUUR) matrix that has been investigated and used for soft tissue repair in a variety of settings. The purpose of this study was to evaluate the safety profile of a PUUR matrix in a large cohort of patients undergoing soft tissue repairs about the foot and ankle. Methods A retrospective chart review of consecutive patients who underwent surgery using FlexBand to augment a soft tissue repair was performed to evaluate for major and minor complications related to the PUUR matrix. Results. A total of 105 patients with an average >6 months follow-up were included. The most common procedures were spring ligament repair, Achilles tendon repair, and Brostrom. There were 12 complications. Four major complications occurred with only 1 requiring PUUR matrix removal. Patients with wound complications had a higher body mass index (BMI) and rate of smoking. Conclusion Complication rates involving PUUR matrix in soft tissue foot and ankle reconstruction procedures are low and comparable with historical complication rates. The PUUR matrix is safe for use in a variety of soft tissue procedures about the foot and ankle. Level of Evidence: Level 4, Retrospective case-series


2018 ◽  
Vol 47 (13) ◽  
pp. 3277-3283 ◽  
Author(s):  
Huw Lloyd Morgan Williams ◽  
Jonathan Peter Evans ◽  
Nicholas Duncan Furness ◽  
Christopher David Smith

Background: The surgical treatment of recurrent shoulder instability has evolved in recent years to include a variety of soft tissue and bone block procedures, undertaken with either an open or arthroscopic approach. Although the utilization of such techniques has rapidly expanded, the associated risk of complications remains poorly defined. This information is vital for clinical decision making and patient counseling. Purpose: To quantify the complication rate associated with all types of surgery for anterior glenohumeral joint dislocation. Study Design: Systematic review. Methods: A systematic search was undertaken of studies reporting complications from anterior shoulder stabilization surgery. Inclusion criteria were studies published in English between 2000 and 2017 with a minimum 2-year follow-up. Methodological quality of the included studies was assessed with the Methodological Index for Non-Randomized Studies criteria. Complication rates for all undesirable events contributing to the patient outcome were extracted and cumulative rates calculated. Results: Out of 1942 references, 56 studies were included, totaling 4362 procedures among 4336 patients. Arthroscopic soft tissue repair had a complication rate of 1.6% (n = 2805). When repair was combined with arthroscopic remplissage, the rate was 0.5% (n = 219). Open soft tissue repair had a complication rate of 6.2% (n = 219) and open labral repair with remplissage, a rate of 2.3% (n = 79). An open bone block procedure had a complication rate of 7.2% (n = 573) and an arthroscopic bone block procedure, a rate of 13.6% (n = 163). Conclusion: This large systematic review demonstrates the overall complication rates (not purely recurrence rates) in modern shoulder stabilization surgery. With the growing interest in bone block stabilization procedures, including those performed arthroscopically, surgeons should be aware of the 10-fold increase in complications for these procedures over soft tissue arthroscopic surgery and counsel their patients accordingly.


2006 ◽  
Vol 30 (4) ◽  
pp. 233-236 ◽  
Author(s):  
Sarunas Tarasevicius ◽  
Uldis Kesteris ◽  
Romas Jonas Kalesinskas ◽  
Hans Wingstrand

2018 ◽  
Author(s):  
Jonathan S. Friedstat ◽  
Michelle R Coriddi ◽  
Eric G Halvorson ◽  
Joseph J Disa

Wound management and soft-tissue repair can vary depending on the location. The head and neck, chest and back, arm and forearm, hand, abdomen, gluteal area and perineum, thigh, knee, lower leg, and foot all have different local options and preferred free flaps to use for reconstruction. Secondary reconstruction requires a detailed analysis of all aspects of the wound including any scars, soft tissue and/or skin deficits, functional defects, contour defects, complex or composite defects, and/or unstable previous wound coverage. Careful monitoring of both the patient and reconstruction is necessary in the postoperative period to ensure long-term success.   This review contains 2 figures and 17 references. Key Words: free tissue transfer, pedicle flaps, soft-tissue coverage, wound closure, wound healing, wound management, wound reconstruction, tissue flaps


2017 ◽  
Vol 32 (3) ◽  
pp. 141-148 ◽  
Author(s):  
Kathryn E. Smith ◽  
Mateo Garcia ◽  
Kenneth M. Dupont ◽  
Geoffrey B. Higgs ◽  
Ken Gall ◽  
...  