scholarly journals Endoscopic ultrasound-guided trans-duodenal fine-needle biopsy of a small renal mass: case report and review of the literature

2021 ◽  
Vol 27 (1) ◽  
Author(s):  
Justin Kwong ◽  
Gary May ◽  
Michael Ordon

Abstract Background The incidental detection of small renal masses (SRMs) is increasing and biopsy to obtain pathological diagnosis is increasingly proposed as a diagnostic tool to guide further management. Renal mass biopsies are traditionally performed via a percutaneous approach. However, this is not always feasible due to anatomical limitations. A rarely reported alternative biopsy approach for SRMs is endoscopic ultrasound (EUS)-guided fine-needle biopsy (FNB). Herein, we describe a case of EUS-guided trans-duodenal FNB for a SRM that was not amenable to standard percutaneous biopsy. Case presentation A 48-year-old man was incidentally found to have a right-sided SRM measuring 2.9 × 2.2 × 2.4 cm during evaluation for a hernia. It was anterior, interpolar, completely endophytic and near the renal hilum. The tumor was not amenable to traditional percutaneous biopsy due to its anterior location. However, the renal mass was in close proximity to the descending duodenum and so it was felt that an EUS-guided trans-duodenal FNB would be feasible. The procedure was successful without any complications. The specimen adequacy was satisfactory for evaluation and consistent with renal papillary carcinoma with WHO/ISUP grade 3 nuclear changes. Conclusion Our case report demonstrated that EUS-guided trans-duodenal FNB was a safe and feasible approach to obtaining biopsy tissue diagnosis of a SRM that was not amenable to percutaneous biopsy.

2021 ◽  
Author(s):  
Gabriele Delconte ◽  
Federica Cavalcoli ◽  
Andrea Magarotto ◽  
Giovanni Centonze ◽  
Cristina Bezzio ◽  
...  

Introduction: Fine Needle Biopsy (FNB) has been suggested to provide better histological samples as compared to endoscopic ultrasound fine needle aspiration (EUS-FNA). However, studies comparing EUS-FNA and EUS-FNB for pancreatic lesions reported contrasting results. The aim of this study was to compare the clinical performance of EUS-FNA versus EUS-FNB with ProCore needle for the investigation of pancreatic lesions. Methods: We reviewed all patients undergoing EUS for the investigation of pancreatic lesions from August 2012 to September 2018. From August 2012 to January 2015 all procedures were performed with standard needles, whereas from February 2015 to September 2018 the use of ProCore needles had been introduced. Data on diagnostic accuracy, number of needle passes and/or adverse events were collected. Results: 324 patients were retrospectively evaluated: 190 (58.6%) underwent EUS-FNA and 134 (41.4%) EUS-FNB. Both EUS-FNA and EUS-FNB showed high diagnostic accuracy for malignancy [94% (CI 95%:89-97%) vs 94% (CI 95%:89-98%)]. Notable, there were no differences between EUS-FNA and EUS-FNB in terms of sensitivity, specificity, positive and negative likelihood ratio, histological core tissue retrieval, adverse events or number of needle passes. However, subgroup analysis noted a higher diagnostic accuracy for 25G EUS-FNB as compared to 25G EUS-FNA (85,7% vs 55,5%; *p=0.023). Conclusion: EUS-FNB with ProCore needle is safe and feasible in pancreatic lesions. ProCore needle did not provide any advantage in terms of diagnostic accuracy, sensitivity, specificity, positive and/or negative likelihood ratio, or acquisition of core specimen, therefore its routine application is not


2021 ◽  
Vol 93 (6) ◽  
pp. AB247-AB248
Author(s):  
Jin Woo (Gene) Yoo ◽  
Govind Krishna Kumar Nair ◽  
Evan Shorr ◽  
Joseph LaComb ◽  
Vivek Kesar ◽  
...  

Author(s):  
Kazuya Miyamoto ◽  
Kazuyuki Matsumoto ◽  
Kazuki Ocho ◽  
Koji Fujita ◽  
Shigeru Horiguchi ◽  
...  

2016 ◽  
Vol 27 ◽  
pp. ii35
Author(s):  
R. Byrne ◽  
A. Garcia Alonso ◽  
L. Turnbull ◽  
R. Kodavatiganti ◽  
S. Walters

Author(s):  
Annamaria Gesualdo ◽  
Rossana Tamburrano ◽  
Antonia Gentile ◽  
Antonio Giannini ◽  
Giuseppe Palasciano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document