scholarly journals Tracheal intubation with video laryngoscopy in out-of-hospital sitting

Author(s):  
Bin Hu ◽  
Tian Tian ◽  
Fu-Shan Xue
Author(s):  
Jürgen Knapp ◽  
Bettina Eberle ◽  
Michael Bernhard ◽  
Lorenz Theiler ◽  
Urs Pietsch ◽  
...  

Abstract Background Tracheal intubation remains the gold standard of airway management in emergency medicine and maximizing safety, intubation success, and especially first-pass intubation success (FPS) in these situations is imperative. Methods We conducted a prospective observational study on all 12 helicopter emergency medical service (HEMS) bases of the Swiss Air Rescue, between February 15, 2018, and February 14, 2019. All 428 patients on whom out-of-hospital advanced airway management was performed by the HEMS crew were included. The C-MAC video laryngoscope was used as the primary device for tracheal intubation. Intubation procedures were recorded by the video laryngoscope and precise time points were recorded to verify the time necessary for each attempt and the overall procedure time until successful intubation. The videos were further analysed for problems and complications during airway management by an independent reviewer. Additionally, a questionnaire about the intubation procedure, basic characteristics of the patient, circumstances, environmental factors, and the provider’s level of experience in airway management was filled out. Main outcome measures were FPS of tracheal intubation, overall success rate, overall intubation time, problems and complications of video laryngoscopy. Results FPS rate was 87.6% and overall success rate 98.6%. Success rates, overall time to intubation, and subjective difficulty were not associated to the providers’ expertise in airway management. In patients undergoing CPR FPS was 84.8%, in trauma patients 86.4% and in non-trauma patients 93.3%. FPS in patients with difficult airway characteristics, facial trauma/burns or obesity ranges between 87 and 89%. Performing airway management indoors or inside an ambulance resulted in a significantly higher FPS of 91.1% compared to outdoor locations (p < 0.001). Direct solar irradiation on the screen, fogging of the lens, and blood on the camera significantly impaired FPS. Several issues for further improvements in the use of video laryngoscopy in the out-of-hospital setting and for quality control in airway management were identified. Conclusion Airway management using the C-MAC video laryngoscope with Macintosh blade in a group of operators with mixed experience showed high FPS and overall rates of intubation success. Video recording emergency intubations may improve education and quality control.


2019 ◽  
Vol 38 (4) ◽  
pp. 259
Author(s):  
Kevin Emmerich ◽  
Michael Steuerwald ◽  
Nick Lepa ◽  
Louis Scrattish ◽  
Ryan Wubben ◽  
...  

2019 ◽  
Vol 129 (2) ◽  
pp. 482-486 ◽  
Author(s):  
Bingdong Tao ◽  
Kun Liu ◽  
Ping Zhao ◽  
Dandan Wang ◽  
Yiming Liu ◽  
...  

2019 ◽  
Author(s):  
Lianxiang Jiang ◽  
Shulin Qiu ◽  
Peng Zhang ◽  
Weidong Yao ◽  
Yan Chang ◽  
...  

Abstract Background: Previous studies have demonstrated that the common laryngoscopic approach (right-sided) and midline approach are both used for endotracheal intubation by direct laryngoscopy. Although the midline approach is commonly recommended for video laryngoscopy (VL) in the clinic, there is a lack of published evidences to support this practice. This study aimed to evaluate the effects of different video laryngoscopic approaches on intubation. Methods: Two hundred sixty-two patients aged 18 years who underwent elective surgery under general anaesthesia and required endotracheal intubation were included in the present prospective, randomized, controlled study. The participants were randomly and equally allocated to the right approach (Group R) or midline approach (Group M). All the intubations were conducted by experienced anaesthetists using GlideScope video laryngoscopy. The primary outcomes were Cormack-Lehane laryngoscopic views (CLVs) and first-pass success (FPS) rates. The secondary outcomes were the time to glottis exposure, time to tracheal intubation, haemodynamic responses and other adverse events. Comparative analysis was performed between the groups. Results: Finally, 262 patients completed the study, and all the tracheas were successfully intubated. No significant differences were observed in the patient characteristics and airway assessments ( P >0.05). Compared with Group R, Group M had a better CLV ( χ2 =14.706, P =0.001) and shorter times to glottis exposure (8.82±2.04 vs 12.38±1.81; t =14.94; P <0.001) and tracheal intubation (37.19±5.01 vs 45.23±4.81; t =13.25; P <0.001), but no difference was found in the FPS rate (70.2% vs 71.8%; χ2 =0.074; P =0.446) and intubation procedure time (29.86±2.56 vs 30.46±2.97, t =1.75, P =0.081). Between the groups, the rates of hoarseness or sore throat, minor injury, hypoxemia and changes in SBP and HR showed no significant difference ( P >0.05). Conclusion: Although the FPS rate did not differ based on the laryngoscopic approach, the midline approach could provide better glottis exposure and shorter times to glottis exposure and intubation. The midline approach should be recommended for teaching in VL-assisted endotracheal intubation. Trial registration: The study was registered in the Chinese Clinical Trial Registry ( ChiCTR-RNC-1900023252 ).


2020 ◽  
Vol 40 (1) ◽  
pp. 39
Author(s):  
B. Tao ◽  
K. Liu ◽  
P. Zhao ◽  
D. Wang ◽  
Y. Liu ◽  
...  

Resuscitation ◽  
2008 ◽  
Vol 77 (2) ◽  
pp. 155-156 ◽  
Author(s):  
Takuma Sadamori ◽  
Shinji Kusunoki ◽  
Makoto Ishida ◽  
Tadatsugu Otani ◽  
Koichi Tanigawa

Sign in / Sign up

Export Citation Format

Share Document