scholarly journals Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial

Author(s):  
Sandra Häberle ◽  
Gunther Hubertus Sandmann ◽  
Stephan Deiler ◽  
Tobias Maximilian Kraus ◽  
Florian Fensky ◽  
...  
2013 ◽  
Vol 27 (3) ◽  
pp. 130-133 ◽  
Author(s):  
Stuart H. Hershman ◽  
Igor Immerman ◽  
Christopher Bechtel ◽  
Nikola Lekic ◽  
Nader Paksima ◽  
...  

2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


Author(s):  
M. Carolina Orbay ◽  
Jorge L. Orbay

AbstractGreater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.


Sign in / Sign up

Export Citation Format

Share Document