Extracellular matrix protein signature in cervical artery dissection

Neurology ◽  
2020 ◽  
Vol 95 (15) ◽  
pp. 663-664
Author(s):  
Christopher Traenka ◽  
Stéphanie Debette
Neurology ◽  
2020 ◽  
Vol 95 (15) ◽  
pp. e2047-e2055 ◽  
Author(s):  
Lukas Mayer ◽  
Raimund Pechlaner ◽  
Javier Barallobre-Barreiro ◽  
Christian Boehme ◽  
Thomas Toell ◽  
...  

ObjectiveTo assess whether connective tissue disorder is evident in patients with spontaneous cervical artery dissection and therefore identify patients at risk of recurrence using a cutting-edge quantitative proteomics approach.MethodsIn the ReSect study, all patients with spontaneous cervical artery dissection treated at the Innsbruck University Hospital since 1996 were invited to attend a standardized clinical follow-up examination. Protein abundance in skin punch biopsies (n = 50) was evaluated by a cutting-edge quantitative proteomics approach (liquid chromatography–mass spectrometry) that has hitherto not been applied to such patients.ResultsPatients with 1-time single-vessel (n = 19) or multiple-vessel (n = 13) dissections did not differ between each other or compared to healthy controls (n = 12) in protein composition. Patients with recurrent spontaneous cervical artery dissection (n = 6), however, showed significantly different expression of 25 proteins compared to the other groups combined. Literature review and Gene Ontology term annotation check revealed that 13 of the differently expressed proteins play a major role in the structural integrity of connective tissue or are linked to connective tissue disorders. These proteins showed clustering to a collagen/elastin cluster and one consisting of desmosome related proteins.ConclusionThis study unravels an extracellular matrix protein signature of recurrent spontaneous cervical artery dissection. In the long run and after large-scale validation, our findings may well assist in identifying patients at risk of recurrent spontaneous cervical artery dissection and thus guide therapy.


2006 ◽  
Vol 23 (4) ◽  
pp. 299-303 ◽  
Author(s):  
Benoît Guillon ◽  
Jacqueline Peynet ◽  
Marion Bertrand ◽  
Lamia Benslamia ◽  
Marie-Germaine Bousser ◽  
...  

2007 ◽  
Vol 177 (4S) ◽  
pp. 421-422
Author(s):  
Ganka Nikolova ◽  
Christian O. Twiss ◽  
Hane Lee ◽  
Nelson Stanley ◽  
Janet Sinsheimer ◽  
...  

2020 ◽  
Vol 88 (3) ◽  
pp. 596-602
Author(s):  
Setareh Salehi Omran ◽  
Neal S. Parikh ◽  
Sharon Poisson ◽  
Jennifer Armstrong ◽  
Alexander E. Merkler ◽  
...  

Author(s):  
Aniel Moya-Torres ◽  
Monika Gupta ◽  
Fabian Heide ◽  
Natalie Krahn ◽  
Scott Legare ◽  
...  

Abstract The production of recombinant proteins for functional and biophysical studies, especially in the field of structural determination, still represents a challenge as high quality and quantities are needed to adequately perform experiments. This is in part solved by optimizing protein constructs and expression conditions to maximize the yields in regular flask expression systems. Still, work flow and effort can be substantial with no guarantee to obtain improvements. This study presents a combination of workflows that can be used to dramatically increase protein production and improve processing results, specifically for the extracellular matrix protein Netrin-1. This proteoglycan is an axon guidance cue which interacts with various receptors to initiate downstream signaling cascades affecting cell differentiation, proliferation, metabolism, and survival. We were able to produce large glycoprotein quantities in mammalian cells, which were engineered for protein overexpression and secretion into the media using the controlled environment provided by a hollow fiber bioreactor. Close monitoring of the internal bioreactor conditions allowed for stable production over an extended period of time. In addition to this, Netrin-1 concentrations were monitored in expression media through biolayer interferometry which allowed us to increase Netrin-1 media concentrations tenfold over our current flask systems while preserving excellent protein quality and in solution behavior. Our particular combination of genetic engineering, cell culture system, protein purification, and biophysical characterization permitted us to establish an efficient and continuous production of high-quality protein suitable for structural biology studies that can be translated to various biological systems. Key points • Hollow fiber bioreactor produces substantial yields of homogenous Netrin-1 • Biolayer interferometry allows target protein quantitation in expression media • High production yields in the bioreactor do not impair Netrin-1 proteoglycan quality Graphical abstract


2002 ◽  
Vol 267 (4) ◽  
pp. 440-446 ◽  
Author(s):  
A. Kapetanopoulos ◽  
F. Fresser ◽  
G. Millonig ◽  
Y. Shaul ◽  
G. Baier ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document