scholarly journals Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device

Neurosurgery ◽  
2016 ◽  
Vol 79 (1) ◽  
pp. 14-22 ◽  
Author(s):  
Ning Lin ◽  
Giuseppe Lanzino ◽  
Demetrius K. Lopes ◽  
Adam S. Arthur ◽  
Christopher S. Ogilvy ◽  
...  

Abstract BACKGROUND Utilization of the Pipeline embolization device (PED) to treat distal carotid circulation aneurysms has not been well studied. OBJECTIVE: To report the collective experience of using PED to treat distal anterior circulation aneurysms. METHODS: We retrospectively reviewed clinical and radiographic records of all patients who underwent Pipeline embolization of distal anterior circulation aneurysms at 10 US neurosurgical centers between 2011 and 2013. RESULTS: Twenty-eight patients (mean age 51.7 years; 18 women) with 28 aneurysms were included in the analyses. Fifteen aneurysms were fusiform, 5 dissecting, and 8 saccular. Average aneurysm size was 12.3 mm; 7 were giant. Twenty aneurysms were located along the middle cerebral artery, 6 along the anterior cerebral artery, and 2 along the anterior communicating artery. PED deployment was successful in 27 patients, with coils utilized in 6 cases. Clinical follow-up was available for an average of 10.7 months (range 3-26). Twenty-seven patients had follow-up neurovascular imaging: 21 aneurysms had complete occlusion, 4 had residual neck filling, and 2 had residual dome filling. Periprocedural complications (<30 days) occurred in 3 patients (10.7%), including 1 case of device failure resulting in stroke. Outcomes were good (modified Rankin Scale score 0 to 2) in 27 patients (96.4%) and fair (modified Rankin Scale 3) in 1. CONCLUSION: PED can be utilized in the treatment of distal anterior circulation aneurysms with difficult anatomy for conventional surgical or endovascular techniques. Larger-scale studies with long-term follow-up are needed to further elucidate the durability of PED treatment and its effect on perforator-rich vascular segments.

2018 ◽  
Vol 20 (4) ◽  
pp. 409-414
Author(s):  
Carlos Eduardo Da Silva ◽  
Paulo Eduardo Peixoto De Freitas ◽  
Alicia Del Carmen Becerra Romero ◽  
Fáberson João Mocelin Oliveira ◽  
Márcio Aloisio Bezerra Cavalcanti Rockenbach ◽  
...  

Introduction: The authors present the analysis of the microsurgical clipping of 100 cerebral aneurysms of the anterior circulation and compare the series data with the literature. Methods: Eighty-eight patients presenting with 100 anterior circulation aneurysms operated on microsurgical techniques between 2002 and 2008 by the first author (CES) were retrospectively reviewed. Results: A total of 88 patients with 100 aneurysms of the anterior circulation were treated in a six years period. Fifty eight female (66%) and thirty male (34%) with nine patients (10.2%) presenting with multiple aneurysms. The mean age was 52 years (range from 26 to 76 years). Eighty five percent of the cases were ruptured aneurysms. The mean follow-up was 52.4 months (range from 5 to 76 months). The topography of the aneurysms was distributed as it follows: Anterior communicating artery (ACoA) 25%; posterior communicating artery (p-comm) 29%; middle cerebral artery (MCA) 27%; paraclinoidal aneurysms 8%; pericallosal artery 6% and internal carotid artery (ICA) tip 5%. The mortality was 7.9%, and such cases presenting with Hunt Hess graduation 3 and 4. The permanent morbidity was 4.5%, cases with Hunt Hess graduation 3 and 4. Perioperative rupture occurred in 17% of the cases, only in previous ruptured aneurysms. There was no clinical evidence of rebleeding during the follow-up period of the series. Conclusions: The microsurgical clipping of cerebral aneurysms of the anterior circulation is a safe and curative treatment for most of such lesions. At present, studies suggest evidences of superior results of surgery compared to the endovascular techniques in the rates of total occlusion of the aneurysms, lesser rates of rebleeding of the treated cases. The results of the present series are similar to the rates of the most relevant literature.


2018 ◽  
Vol 130 (1) ◽  
pp. 259-267 ◽  
Author(s):  
Matthew T. Bender ◽  
Geoffrey P. Colby ◽  
Li-Mei Lin ◽  
Bowen Jiang ◽  
Erick M. Westbroek ◽  
...  

OBJECTIVEFlow diversion requires neointimal stent overgrowth to deliver aneurysm occlusion. The existing literature on aneurysm occlusion is limited by heterogeneous follow-up, variable antiplatelet regimens, noninvasive imaging modalities, and nonstandard occlusion assessment. Using a large, single-center cohort with low attrition and standardized antiplatelet tapering, the authors evaluated outcomes after flow diversion of anterior circulation aneurysms to identify predictors of occlusion and aneurysm persistence.METHODSData from a prospective, IRB-approved database was analyzed for all patients with anterior circulation aneurysms treated by flow diversion with the Pipeline embolization device (PED) at the authors’ institution. Follow-up consisted of catheter cerebral angiography at 6 and 12 months postembolization. Clopidogrel was discontinued at 6 months and aspirin was reduced to 81 mg daily at 12 months. Occlusion was graded as complete, trace filling, entry remnant, or aneurysm filling. Multivariate logistic regression was performed to identify predictors of aneurysm persistence.RESULTSFollow-up catheter angiography studies were available for 445 (91%) of 491 PED procedures performed for anterior circulation aneurysms between August 2011 and August 2016. Three hundred eighty-seven patients accounted for these 445 lesions with follow-up angiography. The population was 84% female; mean age was 56 years and mean aneurysm size was 6.6 mm. Aneurysms arose from the internal carotid artery (83%), anterior cerebral artery (13%), and middle cerebral artery (4%). Morphology was saccular in 90% of the lesions, and 18% of the aneurysms has been previously treated. Overall, complete occlusion was achieved in 82% of cases at a mean follow-up of 14 months. Complete occlusion was achieved in 72%, 78%, and 87% at 6, 12, and 24 months, respectively. At 12 months, adjunctive coiling predicted occlusion (OR 0.260, p = 0.036), while male sex (OR 2.923, p = 0.032), aneurysm size (OR 3.584, p = 0.011), and incorporation of a branch vessel (OR 2.206, p = 0.035) predicted persistence. Notable variables that did not predict aneurysm occlusion were prior treatments, vessel of origin, fusiform morphology, and number of devices used.CONCLUSIONSThis is the largest single-institution study showing high rates of anterior circulation aneurysm occlusion after Pipeline embolization. Predictors of persistence after flow diversion included increasing aneurysm size and incorporated branch vessel, whereas adjunctive coiling predicted occlusion.


2017 ◽  
Vol 42 (6) ◽  
pp. E16 ◽  
Author(s):  
Visish M. Srinivasan ◽  
Andrew P. Carlson ◽  
Maxim Mokin ◽  
Jacob Cherian ◽  
Stephen R. Chen ◽  
...  

OBJECTIVEThe Pipeline embolization device (PED) is frequently used in the treatment of anterior circulation aneurysms, especially around the carotid siphon, with generally excellent results. However, the PED has its own unique technical challenges, including the occurrence of device foreshortening or migration leading to prolapse into the aneurysm. The authors sought to determine the incidence of this phenomenon, the rescue strategies, and outcomes.METHODSFour institutional databases of neuroendovascular procedures were reviewed for cases of intracranial aneurysms treated with PEDs. Patient and aneurysm data as well as angiographic imaging were reviewed for all cases involving device prolapse into the aneurysm.RESULTSA total of 413 intracranial aneurysms were treated with PEDs during the study period, by 5 neurointerventionalists. Large and giant aneurysms (≥ 2 cm) accounted for 32 of these aneurysms. Among these 32 PEDs, prolapse into the aneurysm occurred in 3 patients, with 1 of these PEDs successfully rescued and the other 2 left in situ. No patients suffered any severe complications. The 2 patients in whom the PEDs were left in situ remained on antiplatelet therapy.CONCLUSIONSThe PED may foreshorten or migrate during or after deployment, leading to prolapse into the aneurysm. This phenomenon appears to be associated with large and giant aneurysms, vessel tortuosity, short landing zones, and use of balloon angioplasty. Future study and follow-up is needed to further evaluate this phenomenon, but some of the observations and techniques described in this paper may help to prevent or salvage prolapsed devices.


1973 ◽  
Vol 38 (4) ◽  
pp. 481-487 ◽  
Author(s):  
Michael Scott

✓ The clinical data on nine patients with aneurysms of the anterior communicating artery complex treated by ligation of an anterior cerebral artery are presented. The long-term follow-up angiograms on five of the eight patients who survived surgery are discussed.


2011 ◽  
Vol 114 (4) ◽  
pp. 944-953 ◽  
Author(s):  
H. Saruhan Cekirge ◽  
Kivilcim Yavuz ◽  
Serdar Geyik ◽  
Isil Saatci

Object The purpose of this paper was to present the safety, efficacy, and clinical/angiographic follow-up results of HyperForm balloon-assisted endosaccular coil occlusion of distal anterior circulation bifurcation aneurysms. Methods Over a 7-year period, the authors treated 864 middle cerebral artery, distal anterior cerebral artery bifurcation, and anterior communicating artery aneurysms by means of coil embolization with HyperForm balloon assistance in 800 patients. In 37 aneurysms, 2 HyperForm balloons were used simultaneously for remodeling. Results The overall mortality rate was 7.1%, including 1.4% procedural mortality. Various neurological deficits were present at discharge in 8.9% of the patients, and 4.4% had permanent disabling morbidity 6 months posttreatment (modified Rankin Scale score ≥ 2). Thromboembolic complications developed during the treatment of 15 aneurysms (1.7%) causing morbidity or mortality in 10 cases (1.3%). There were 14 intraoperative perforations (1.6%). In all 14 cases, the HyperForm balloon saved patients from severe bleeding. The perforation led to morbidity or mortality in 3 cases (0.4%); there were no negative consequences in 11. There were 726 patients with 757 aneurysms (87.6%) available for follow-up. Control angiograms were obtained at 6 months in 386 patients, at 1 year in 267, and at 2 years in 104, revealing an 82% complete obliteration rate according to the most recent follow-up angiograms. Conclusions The satisfactory results obtained in this experience demonstrate that HyperForm balloon remodeling provides strong benefits for the endovascular management of middle cerebral, anterior cerebral, and anterior communicating artery aneurysms without increasing the risk of treatment. Not only does this technique allow for the safe treatment of these aneurysms, but it also expands the indications of endovascular treatment to include aneurysms that otherwise cannot be treated with simple coil embolization.


2019 ◽  
Vol 23 (4) ◽  
Author(s):  
MUHAMMAD JAHANGIR KHAN ◽  
MUHAMMAD HAMMAD NASIR ◽  
SIKANDAR ALI ◽  
SARFRAZ KHAN ◽  
MUHAMMAD WAQAS ◽  
...  

Objective: The objective of the study was to analyze the operative outcome of microsurgical clipping in Ruptured Anterior Circulation Aneurysms.Materials and Methods: Twenty patients with Ruptured Anterior Circulation aneurysms were treated with surgical clipping. All the patients were evaluated pre-operatively according to Hunt & Hess and WFNS grading scales. Patients with grade I, II, and III were operated. All the aneurysms were clipped through Pterional approach under General anesthesia and Yasargil Aneurysm clips of appropriate sizes were used in each patient. Outcome was analyzed according to Glasgow Outcome Scale at the end of six months of follow up in each patient.Results: In this series of twenty cases, the mean patient age was 49 years. Lesion location included, the ACA/A. Com 55% (n = 11), the Middle Cerebral artery 25% (n = 5), P. Com 15% (n = 3), Ophthalmic artery 5% (n = 1). Sex distribution, female 55% (n = 11) and male 45% (n = 9). Per-operative complications, rupture of aneurysm 20% (n = 4), and damage to perforating branches of MCA 5% (n = 1). Conclusions: Surgical clipping still is the most efficient treatment of Ruptured Anterior Circulation aneurysm at the beginning of the new millennium. Anterior Communicating Artery is the commonest location of aneurysms. Major determinants of outcome are Hunt & Hess, WFNS grades on admission and the age of the patient.


2019 ◽  
Vol 130 (4) ◽  
pp. 1376-1382 ◽  
Author(s):  
Badih Daou ◽  
Elias Atallah ◽  
Nohra Chalouhi ◽  
Robert M. Starke ◽  
Jeffrey Oliver ◽  
...  

OBJECTIVEThe Pipeline embolization device (PED) has become a valuable tool in the treatment of cerebral aneurysms. Although failures with PED treatment have been reported, the characteristics and course of these aneurysms remain a topic of uncertainty.METHODSElectronic medical records and imaging studies were reviewed for all patients treated with the PED between July 2010 and March 2015 to identify characteristics of patients and aneurysms with residual filling after PED treatment.RESULTSOf 316 cases treated at a single institution, 281 patients had a long-term follow-up. A total of 52 (16.4%) aneurysms with residual filling were identified and constituted the study population. The mean patient age in this population was 58.8 years. The mean aneurysm size was 10.1 mm ± 7.15 mm. Twelve aneurysms were fusiform (23%). Of the aneurysms with residual filling, there were 20 carotid ophthalmic (CO) aneurysms (20% of all CO aneurysms treated), 10 other paraclinoid aneurysms (16.4% of all paraclinoid aneurysms), 7 posterior communicating artery (PCoA) aneurysms (21.9% of all PCoA aneurysms), 7 cavernous internal carotid artery (ICA) aneurysms (14.9% of all cavernous ICA aneurysms), 4 vertebrobasilar (VB) junction aneurysms (14.8% of all VB junction aneurysms), and 3 middle cerebral artery (MCA) aneurysms (25% of all MCA aneurysms). Eleven patients underwent placement of more than one PED (21.2%), with a mean number of devices of 1.28 per case. Eight of 12 aneurysms were previously treated with a stent (15.4%). Nineteen patients underwent re-treatment (36.5%); the 33 patients who did not undergo re-treatment (63.5%) were monitored by angiography or noninvasive imaging. In multivariate analysis, age older than 65 years (OR 2.65, 95% CI 1.33–5.28; p = 0.05), prior stent placement across the target aneurysm (OR 2.94, 95% CI 1.15–7.51; p = 0.02), aneurysm location in the distal anterior circulation (MCA, PCoA, and anterior choroidal artery: OR 2.72, 95% CI 1.19–6.18; p = 0.017), and longer follow-up duration (OR 1.06, 95% CI 1.03–1.09; p < 0.001) were associated with incomplete aneurysm occlusion.CONCLUSIONSWhile the PED can allow for treatment of large, broad-necked aneurysms with high efficacy, treatment failures do occur (16.4%). Aneurysm size, shape, and previous treatment may influence treatment outcome.


Sign in / Sign up

Export Citation Format

Share Document