scholarly journals Prolapse of the Pipeline embolization device in aneurysms: incidence, management, and outcomes

2017 ◽  
Vol 42 (6) ◽  
pp. E16 ◽  
Author(s):  
Visish M. Srinivasan ◽  
Andrew P. Carlson ◽  
Maxim Mokin ◽  
Jacob Cherian ◽  
Stephen R. Chen ◽  
...  

OBJECTIVEThe Pipeline embolization device (PED) is frequently used in the treatment of anterior circulation aneurysms, especially around the carotid siphon, with generally excellent results. However, the PED has its own unique technical challenges, including the occurrence of device foreshortening or migration leading to prolapse into the aneurysm. The authors sought to determine the incidence of this phenomenon, the rescue strategies, and outcomes.METHODSFour institutional databases of neuroendovascular procedures were reviewed for cases of intracranial aneurysms treated with PEDs. Patient and aneurysm data as well as angiographic imaging were reviewed for all cases involving device prolapse into the aneurysm.RESULTSA total of 413 intracranial aneurysms were treated with PEDs during the study period, by 5 neurointerventionalists. Large and giant aneurysms (≥ 2 cm) accounted for 32 of these aneurysms. Among these 32 PEDs, prolapse into the aneurysm occurred in 3 patients, with 1 of these PEDs successfully rescued and the other 2 left in situ. No patients suffered any severe complications. The 2 patients in whom the PEDs were left in situ remained on antiplatelet therapy.CONCLUSIONSThe PED may foreshorten or migrate during or after deployment, leading to prolapse into the aneurysm. This phenomenon appears to be associated with large and giant aneurysms, vessel tortuosity, short landing zones, and use of balloon angioplasty. Future study and follow-up is needed to further evaluate this phenomenon, but some of the observations and techniques described in this paper may help to prevent or salvage prolapsed devices.

Neurosurgery ◽  
2016 ◽  
Vol 79 (1) ◽  
pp. 14-22 ◽  
Author(s):  
Ning Lin ◽  
Giuseppe Lanzino ◽  
Demetrius K. Lopes ◽  
Adam S. Arthur ◽  
Christopher S. Ogilvy ◽  
...  

Abstract BACKGROUND Utilization of the Pipeline embolization device (PED) to treat distal carotid circulation aneurysms has not been well studied. OBJECTIVE: To report the collective experience of using PED to treat distal anterior circulation aneurysms. METHODS: We retrospectively reviewed clinical and radiographic records of all patients who underwent Pipeline embolization of distal anterior circulation aneurysms at 10 US neurosurgical centers between 2011 and 2013. RESULTS: Twenty-eight patients (mean age 51.7 years; 18 women) with 28 aneurysms were included in the analyses. Fifteen aneurysms were fusiform, 5 dissecting, and 8 saccular. Average aneurysm size was 12.3 mm; 7 were giant. Twenty aneurysms were located along the middle cerebral artery, 6 along the anterior cerebral artery, and 2 along the anterior communicating artery. PED deployment was successful in 27 patients, with coils utilized in 6 cases. Clinical follow-up was available for an average of 10.7 months (range 3-26). Twenty-seven patients had follow-up neurovascular imaging: 21 aneurysms had complete occlusion, 4 had residual neck filling, and 2 had residual dome filling. Periprocedural complications (<30 days) occurred in 3 patients (10.7%), including 1 case of device failure resulting in stroke. Outcomes were good (modified Rankin Scale score 0 to 2) in 27 patients (96.4%) and fair (modified Rankin Scale 3) in 1. CONCLUSION: PED can be utilized in the treatment of distal anterior circulation aneurysms with difficult anatomy for conventional surgical or endovascular techniques. Larger-scale studies with long-term follow-up are needed to further elucidate the durability of PED treatment and its effect on perforator-rich vascular segments.


2015 ◽  
Vol 122 (6) ◽  
pp. 1498-1502 ◽  
Author(s):  
Nohra Chalouhi ◽  
Mario Zanaty ◽  
Alex Whiting ◽  
Steven Yang ◽  
Stavropoula Tjoumakaris ◽  
...  

OBJECT Flow diverters are increasingly used for treatment of intracranial aneurysms. In most series, the Pipeline Embolization Device (PED) was used for the treatment of large, giant, complex, and fusiform aneurysms. Little is known about the use of the PED in small aneurysms. The purpose of this study was to assess the safety and efficacy of the PED in small aneurysms (≤ 7 mm). METHODS A total of 100 consecutive patients were treated with the PED at the authors' institution between May 2011 and September 2013. Data on procedural safety and efficacy were retrospectively collected. RESULTS The mean aneurysm size was 5.2 ± 1.5 mm. Seven patients (7%) had sustained a subarachnoid hemorrhage. All except 5 aneurysms (95%) arose from the anterior circulation. The number of PEDs used was 1.2 per aneurysm. Symptomatic procedure-related complications occurred in 3 patients (3%): 1 distal parenchymal hemorrhage that was managed conservatively and 2 ischemic events. At the latest follow-up (mean 6.3 months), 54 (72%) aneurysms were completely occluded (100%), 10 (13%) were nearly completely occluded (≥ 90%), and 11 (15%) were incompletely occluded (< 90%). Six aneurysms (8%) required further treatment. Increasing aneurysm size (OR 3.8, 95% CI 0.99–14; p = 0.05) predicted retreatment. All patients achieved a favorable outcome (modified Rankin Scale Score 0–2) at follow-up. CONCLUSIONS In this study, treatment of small aneurysms with the PED was associated with low complication rates and high aneurysm occlusion rates. These findings suggest that the PED is a safe and effective alternative to conventional endovascular techniques for small aneurysms. Randomized trials with long-term follow-up are necessary to determine the optimal treatment that leads to the highest rate of obliteration and the best clinical outcomes.


2021 ◽  
Author(s):  
Marta Aguilar Pérez ◽  
Elina Henkes ◽  
Victoria Hellstern ◽  
Carmen Serna Candel ◽  
Christina Wendl ◽  
...  

Abstract BACKGROUND Flow diverters have become an important tool in the treatment of intracranial aneurysms, especially when dealing with difficult-to-treat or complex aneurysms. The p64 is the only fully resheathable and mechanically detachable flow diverter available for clinical use. OBJECTIVE To evaluate the safety and effectiveness of p64 for the treatment of intracranial saccular unruptured aneurysms arising from the anterior circulation over a long-term follow-up period. METHODS We retrospectively reviewed our prospectively maintained database to identify all patients who underwent treatment for an intracranial saccular (unruptured or beyond the acute hemorrhage phase) aneurysm arising from the anterior circulation with ≥1 p64 between December 2011 and December 2019. Fusiform aneurysms and dissections were excluded. Aneurysms with prior or concomitant saccular treatment (eg, coiling and clipping) were included. Aneurysms with parent vessel implants other than p64 were excluded. Anatomic features, intraprocedural complications, clinical outcome, as well as clinical and angiographic follow-ups were all recorded. RESULTS In total, 530 patients (388 females; median age 55.9 yr) with 617 intracranial aneurysms met the inclusion criteria. The average number of devices used per aneurysm was 1.1 (range 1-3). Mean aneurysm dome size was 4.8 mm (range 1-27 mm). Treatment-related morbimortality was 2.4%. Early, mid-term, and long-term angiographic follow-up showed complete or near-complete aneurysm occlusion in 76.8%, 89.7%, and 94.5%, respectively. CONCLUSION Treatment of intracranial saccular unruptured aneurysms of the anterior circulation using p64 is a safe and effective treatment option with high rate of occlusion at long-term follow-up and low morbimortality.


Author(s):  
Juan Vivanco‐Suarez ◽  
Alan Mendez‐Ruiz ◽  
Farooqui Mudassir ◽  
Cynthia B Zevallos ◽  
Milagros Galecio‐Castillo ◽  
...  

Introduction : Flow diversion has established itself as standard treatment of wide complex intracranial aneurysms (IA). Its recognition has been validated with positive occlusion rates and favorable clinical outcomes. The Surpass Streamline (SS) flow diverter (FD) is a braided cobalt/chromium alloy implant with 72 or 96 wires approved by the FDA in 2018. The aim of this study is to determine the safety and efficacy of the SS in a post‐marketing large US cohort. Methods : We performed a multicenter, retrospective study for consecutive patients treated with the SS FD for IA between January 2018 and June 2021 in the United States. Inclusion criteria for participants were: 1. Adults (≥ 18 years) and 2. Treatment with SS FD for IA. Primary safety end point was a major ipsilateral stroke (increase in National Institutes of Health Stroke Scale Score of ≥ 4) or neurological death within 12 months. Primary efficacy was assessed using the 3‐point Raymond‐Roy (RR) occlusion scale on digital subtraction angiography (DSA) at 6‐12‐month follow‐up. Results : A total of 276 patients with 313 aneurysms were enrolled. The median age was 59 years and 199 (72%) were females. The most common comorbidities included hypertension in 156 (57%) subjects followed by hyperlipidemia in 76 (28%) patients. One hundred and twenty‐two (44%) patients were asymptomatic while subarachnoid hemorrhage was present in only 10 (4%) patients. A total of 143 (46%) aneurysms were left‐sided. Aneurysms were located as follows: 274 (88%) were in the anterior circulation with paraophthalmic being the most common in 120 (38%) followed by petrocavernous ICA in 81 (26%); 33 (11%) aneurysms were located in the posterior circulation with basilar trunk being the most common in 14 (5%). The mean maximum aneurysm dome width was 5.77 ± 4.7 mm, neck width 4.22 ± 3.8 mm and dome to neck ratio was 1.63 ± 1.3 mm. The mean number of SS FD implanted per aneurysm was 1.06 (range 1–3) with more than one SS FD implanted in 21 (7%) aneurysms. Modified Rankin Scale (mRS) of 0–2 was present in 206/213 (97%) patients at 6–12 month follow‐up. The complete aneurysm occlusion (RR 1) rate was 145/175 (83%) among subjects who had angiographic follow‐up at 6–12 months. Major stroke and death was encountered in 7 (2%) and 5 (1.8%) of the patients respectively. Conclusions : Our data represent the largest real‐world study using SS FD. These results corroborate its post‐marketing safety and efficacy for the treatment of intracranial aneurysms showing more favorable rates to the initial experience during SCENT trial.


Stroke ◽  
2014 ◽  
Vol 45 (suppl_1) ◽  
Author(s):  
Ajay K Wakhloo ◽  
Pedro Lylyk ◽  
Joost de Vries ◽  
Matthew J Gounis ◽  
Alexandra Biondi ◽  
...  

Objective: Validated through experimental studies a new generation of flow diverters (Surpass™ FD) was evaluated for treatment of intracranial aneurysms (IA). We present our multicenter preliminary clinical and angiographic experience. METHODS: To achieve the calculated flow disruption between the parent artery and aneurysm for thrombosis, single FDs were placed endovascularly in parent arteries. Implants measured 2.5-5.3mm in diameter with a length of 10-80mm. Patients were enrolled harboring a wide range large and giant wide-neck, fusiform and multiple small and blister-type aneurysm. Clinical and angiographic follow-up were performed at 1-3, 6, and 12 months. RESULTS: A total of 186 consecutive IA in 161 patients (mean age 57.1 years) were treated at 33 centers. Fifty-three aneurysms were smaller than 5 mm, 64 were 5-9.9mm in diameter, 47 were 10-20mm in diameter, and 22 were larger than 20mm (10.4±0.7mm, neck size 6.0±0.5mm [mean±SEM]) . The aneurysms originated in 63.4% from the internal carotid artery; 22% and 14.5% of the lesions were located in the anterior circulation distal to Circle of Willis and posterior circulation respectively. Technical success was achieved in 182 aneurysms (98%); average number of devices used per aneurysm was 1.05. Permanent morbidity and mortality during the follow-up period of mean 8.4months (range 1-24 months) including periprocedural complications for patients with aneurysms of the anterior circulation were encountered in 5 (3.7%) and 2 (1.5 %) patients respectively and 1 (3.7%) and 4 (14.8%) respectively for patients with aneurysms of the posterior circulation location. One-hundred-ten patients (70.5%) harboring 127 (70.2%) were available for clinical and angiographic follow-up and showed a complete or near complete aneurysm occlusion in 63 (81.8%) of the ICA. Aneurysms of the ICA≥10mm that were completely covered by FD and not previously stent-treated with a minimum of 6 months follow-up available in 16 patients showed a complete obliteration in 81.3% (n=13) and >90% occlusion in remaining 3 patients. CONCLUSION: Preliminary data demonstrate high safety and efficacy of a new generation of FD for a wide range of IA of the anterior and posterior circulation with a single implant.


2004 ◽  
Vol 62 (2a) ◽  
pp. 245-249 ◽  
Author(s):  
Leodante Batista da Costa Jr ◽  
Josaphat Vilela de Morais ◽  
Agustinho de Andrade ◽  
Marcelo Duarte Vilela ◽  
Renato P. Campolina Pontes ◽  
...  

Spontaneous subarachnoid hemorrhage accounts for 5 to 10 % of all strokes, with a worldwide incidence of 10.5 / 100000 person/year, varying in individual reports from 1.1 to 96 /100000 person/year. Angiographic and autopsy studies suggest that between 0.5% and 5% of the population have intracranial aneurysms. Approximately 30000 people suffer aneurysmal subarachnoid hemorrhage in the United States each year, and 60% die or are left permanently disabled. We report our experience in the surgical treatment of intracranial aneurysms in a six year period, in Belo Horizonte, Minas Gerais, Brazil. We reviewed the hospital files, surgical and out-patient notes of all patients operated on for the treatment of intracranial aneurysms from January 1997 to January 2003. Four hundred and seventy-seven patients were submitted to 525 craniotomies for treatment of 630 intracranial aneurysms. The majority of patients were female (72.1%) in the fourth or fifth decade of life. Anterior circulation aneurysms were more common (94.4%). The most common location for the aneurysm was the middle cerebral artery bifurcation. The patients were followed by a period from 1 month to 5 years. The outcome was measured by the Glasgow Outcome Scale (GOS). At discharge, 62.1% of the patients were classified as GOS 5, 13.9% as GOS 4, 8.7% as GOS 3, 1.7% as GOS 2 and 14.8% as GOS 1.


2020 ◽  
Author(s):  
Lixia Xia ◽  
Zhongfei Hao ◽  
Hongjun Wang ◽  
Yan Feng ◽  
Yongxuan Zhan ◽  
...  

Abstract Background: Ruptured tiny intracranial aneurysm (RTIA) is particularly rare seen. Treatment of RTIA is more difficult and not under control.Methods: We hereby present twelve rare cases of RTIA that were diagnosed based on DSA. These patients were found due to spontaneous or traumatic SAH, 11 of whom were treated only by electrocoagulation, and one of whom was treated by stent-assisted coiling and electrocoagulation.Results: There were eight patients with aneurysms located in posterior circulation and four patients with aneurysms located in anterior circulation. 11 patients were cured only by electrocoagulation merely: ten patient’ RTIA disappeared completely and immediately and another patient’s RTIA was thrombosed two months later. The twelfth patient was carried out stent-assisted coiling and electrocoagulation. The twelve patients’ average follow-up time was 12.5 months and the outcomes were all surprisingly excellent. No revascularization of aneurysm was found. Conclusions: Electrocoagulation with guidewire manipulation is a suitable method to treat RTIA. While large-scale studies with long-term follow-up are required to validate these promising results.


2011 ◽  
Vol 17 (4) ◽  
pp. 420-424 ◽  
Author(s):  
W. Yue

We report the clinical and angiographic results of endovascular treatment of unruptured intracranial aneurysms. Over a three-year period, 80 unruptured aneurysms in 74 patients were electively treated with endovascular management. One aneurysm was diagnosed during investigations for a second ruptured aneurysm, 54 aneurysms were incidentally discovered, 18 aneurysms presented with symptoms of mass effect and seven aneurysms presented with symptoms of brain stem ischemia. Mean size of the 80 unruptured aneurysms was 12.5±8.0 mm (range, 2–39 mm). Thirty-six aneurysms (45%) were small (<10 mm), 38 aneurysms (47.5%) were large (10–25 mm), and six aneurysms (7.5%) were giant (25–39 mm). Forty-eight wide-necked aneurysms (60%) were coiled with the aid of a supporting device. The mortality rate was 1.25%, and the overall morbidity was 1.25%. Of these, one of the patients suffered a stroke, leading to severe disability (1.25%). In one patient, the aneurysm ruptured during treatment, resulting in death. Initial aneurysm occlusion was complete (100%) in 76.25% aneurysms, nearly complete (90%–98%) in 10% aneurysms and incomplete (60%–85%) in 13.75% aneurysms. Follow-up angiography was available in 67 patients with 73 treated aneurysms (91.25%) from one to 36 months (mean 9.3 months); partial reopening occurred in 7.5%, mainly large and giant aneurysms (5.5%). Additional coiling was performed in four aneurysms. There were no complications in additional treatments. At 14.1-month clinical follow-up (range, 2 to 36 months), mRS score was 0 in 78.75% patients, 1 in 10% patients, 2 in 8.75% and 3 in 1.25%. There was no aneurysmal rupture during the follow-up period. Endovascular treatment of unruptured intracranial aneurysms has low procedural mortality and morbidity rates.


1999 ◽  
Vol 5 (1_suppl) ◽  
pp. 93-96 ◽  
Author(s):  
C.F. Dowd ◽  
C.C. Phatouros ◽  
A.M. Malek ◽  
T.E. Lempert ◽  
P.M. Meyers ◽  
...  

Options for treatment of intracranial aneurysms have expanded with the advent of the Guglielmi Detachable Cod (GDC) eight years ago. We have reviewed 435 cases of intracranial aneurysms treated at UCSF by endovascular means using the GDC system. Of these, 55% represent anterior circulation aneurysms, and 45% are located in the posterior circulation. Additionally, 55% of the aneurysms presented with subarachnoid hemorrhage (SAH) and 45% were unruptured. Factors which hindered optimal coiling include the following: wide aneurysm neck in relation to the overall aneurysm size, mural thrombus, giant aneurysm, arteries originating from the aneurysm sac, and middle cerebral location. After initial experience was gained, we tended to avoid these aneurysms especially in the non-ruptured group. This may be especially important in light of new epidemiological data suggesting that the natural history of unruptured aneurysms is significantly lower than previously thought. New technical developments which may reduce the risk of treating unruptured aneurysms include the two-dimensional coil, the three-dimensional coil, the balloon-assist technique for wide-necked aneurysms, and combined stent-coil procedures.