Ligament balancing in computer-assisted total knee arthroplasty: Improved clinical results with a spring-loaded tensioning device

Author(s):  
M Swank ◽  
J R Romanowski ◽  
L L Korbee ◽  
S Bignozzi

Total knee arthroplasty (TKA) remains one of the most successful procedures in orthopaedic surgery. Complications certainly exist and are often related to failure of knee ligament balance. This asymmetry subsequently leads to component mal-alignment and loosening often secondary to deviation of the lower extremity mechanical axis. Understanding knee mechanics is essential, and recent technological advances have begun to minimize postoperative problems. A tensioning device that respects the native patellofemoral anatomy as well as the natural ligamentous strains has been developed. The surgical integration of computer-assisted navigation has allowed for enhanced accuracy and subsequently better results. The purpose of the current paper is to discuss the evolution of an improved ligament tensioning device, in the setting of classic mechanical guidance versus computer assistance and its postoperative impact on total knee outcomes in terms of manipulation rates and two-year radiographic alignment data. Based on a single surgeon series, mechanically guided arthroplasties resulted in a 16 per cent manipulation rate. Computer assistance with spacer blocks decreased the manipulation rate to 14 per cent, while using a novel tensioner device further decreased the manipulation rate to 7 per cent, a significant difference of p <0.01. Radiographic data illustrate all TKAs with the tensioner to be within 4° of the desired position.

2018 ◽  
Vol 26 (3) ◽  
pp. 170-174 ◽  
Author(s):  
IZUMI TANI ◽  
NAOKI NAKANO ◽  
KOJI TAKAYAMA ◽  
KAZUNARI ISHIDA ◽  
RYOSUKE KURODA ◽  
...  

ABSTRACT Objective It is difficult to achieve proper alignment after total knee arthroplasty (TKA) in patients with extra-articular deformity (EAD) because of altered anatomical axis and distorted landmarks. As of this writing, only case series have been reported with regard to the usefulness of computer-assisted navigation systems for TKA with EAD. This study therefore compared outcomes in TKA with EAD, with and without navigation. Methods Fourteen osteoarthritis patients with EAD due to previous fracture malunion or operations were assessed. Seven TKAs were performed with navigation (navigation group) and another 7 were performed without navigation (manual group). Clinical and radiographic outcomes were compared before and two years after surgery. Results The mean postoperative Knee Society function score was significantly higher in the navigation group. No significant difference was found in postoperative range of motion and Knee Society knee score. The rate of outliers in radiographic outcomes tended to be lower in the navigation group. Conclusion Better clinical outcomes were achieved in cases in which navigation was used. Computer-assisted navigation is useful in TKA for patients with EAD. Level of Evidence III; Case control study.


2020 ◽  
Vol 28 (1) ◽  
pp. 230949902090570 ◽  
Author(s):  
Yongun Cho ◽  
Hun-Kyu Shin ◽  
Eugene Kim ◽  
Jai Hyung Park ◽  
Se-Jin Park ◽  
...  

Purpose: Total knee arthroplasty (TKA) is the definite treatment for osteoarthritis. Meanwhile, significant inherent extra-articular varus angulation is associated with abnormal postoperative hip–knee–ankle (HKA) angle. Computer-assisted navigation TKA (CAS-TKA) used in patients who have severe varus deformity. The purpose of this study was to compare postoperative radiologic outcome between CAS-TKA and conventional TKA for extra-articular tibia vara. Methods: A retrospective review of postoperative HKA on standing lower extremity views was conducted in patients who underwent TKA by a single surgeon from 2010 to 2018, including knee with conventional TKA ( n = 83) and CAS-TKA ( n = 246). Extra-articular tibia vara was assessed by measuring the metaphyseal–diaphyseal angle (MDA) of the tibia in preoperative standing lower extremity view. Postoperative alignment was assessed by measuring the HKA in postoperative standing lower extremity view. Results: There was no significant difference in age ( p = 0.063), gender ( p = 0.628), body mass index ( p = 0.426), preoperative range of motion ( p = 0.524), preoperative HKA ( p = 0.306), preoperative MDA ( p = 0.523), or postoperative HKA ( p = 0.416) between the two groups (conventional TKA and CAS-TKA). There was no significant difference in postoperative alignment for cases with MDA ≤4° ( p = 0.351) or MDA >4° ( p = 0.866) in each group. There was a positive correlation between preoperative HKA and postoperative HKA in the CAS-TKA group ( p < 0.001, r = 0.243). However, there was no significant correlation between preoperative HKA and postoperative HKA in the conventional TKA group ( p = 0.732). Conclusions: There was no significant difference in postoperative alignment between conventional TKA and CAS-TKA in extra-articular tibial vara even for cases with MDA >4°.


2021 ◽  
Vol 15 (1) ◽  
pp. 79-84
Author(s):  
Leelasestaporn C ◽  
Thuwapitchayanant M ◽  
Sirithanapipat P ◽  
Sa-ngasoongsong P ◽  
Ruengsilsuwit P

2008 ◽  
Vol 13 (3) ◽  
pp. 167-172 ◽  
Author(s):  
Camilo Restrepo ◽  
William J. Hozack ◽  
Fabio Orozco ◽  
Javad Parvizi

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Tanner C. Clark ◽  
Frank H. Schmidt

Background. Since the introduction of robot-assisted navigation in primary total knee arthroplasty (TKA), there has been little research conducted examining the efficiency and accuracy of the system compared to computer-assisted navigation systems. Objective. To compare the efficiency and accuracy of Praxim robot-assisted navigation (RAN) and Stryker computer-assisted navigation (CAN) in primary TKA. Methods. This was a retrospective study consisting of 52 patients who underwent primary TKA utilizing RAN and 29 patients utilizing CAN. The primary outcome measure was navigation time. Secondary outcome measures included intraoperative final mechanical axis alignment, intraoperative robot-assisted bone cut accuracy, tourniquet time, and hospitalization length. Results. RAN navigation times were, on average, 9.0 minutes shorter compared to CAN after adjustment. The average absolute intraoperative malalignment was 0.5° less in the RAN procedures compared to the CAN procedures after adjustment. Patients in the RAN group tended to be discharged 0.6 days earlier compared to patients in the CAN group after adjustment. Conclusions. Among patients undergoing TKA, there was decreased navigation time, decreased final malalignment, and decreased hospitalization length associated with the use of RAN when compared to CAN independent of age, BMI, and pre-replacement alignment.


2010 ◽  
Vol 97-101 ◽  
pp. 3773-3776 ◽  
Author(s):  
Chien Wei Liu ◽  
Chia Chi Lo ◽  
Ching Sung Wang ◽  
Chen Tung Yu

Complications in total knee arthroplasty (TKA), which may include the inaccuracy of the implantation and the poor component design, can cause major failures in the TKA. Therefore, the present investigation studies the onlay knee implants commonly used clinically to find the major causes of the damage to artificial patella by the computer aided analysis of the three-dimensional finite element model of the artificial patello-femoral joint built through reverse engineering. Results showed that although a significant difference is found in the condition and the state of the stress distribution generated as the patello-femoral joint changes with the flexion of the knees, this variation is still within the tolerable range; but the patellar lateral tilt is something that caught our attention. Furthermore, through the comparison between the study and the clinical results, this investigation concludes that the bone cement on the implant interface is the major cause for the breaking of the pegs, and is not related to the original design of the patella. This study also discovers that slight design modification on the parts of commonly used artificial joints may effectively reduce surgical failure rate; therefore, a more robust design configuration for patellar pegs is proposed.


Sign in / Sign up

Export Citation Format

Share Document