Doppler flow spectra of the superior vena cava in a rat model of chronic pulmonary hypertension

2011 ◽  
Vol 45 (2) ◽  
pp. 90-94 ◽  
Author(s):  
Dan Dan Sun ◽  
Hong Mao Chen ◽  
Li Jun Yuan ◽  
Yun You Duan ◽  
Ning Nan Liang ◽  
...  
2009 ◽  
Vol 296 (3) ◽  
pp. H639-H644 ◽  
Author(s):  
Andreas Zierer ◽  
Spencer J. Melby ◽  
Rochus K. Voeller ◽  
Marc R. Moon

The purpose of the present study was to determine for the first time the qualitative and quantitative impact of varying degrees of interatrial shunting on right heart dynamics and systemic perfusion in subjects with chronic pulmonary hypertension (CPH). Eight dogs underwent 3 mo of progressive pulmonary artery banding, following which right atrial and ventricular end-systolic and end-diastolic pressure-volume relations were calculated using conductance catheters. An 8-mm shunt prosthesis was inserted between the superior vena cava and left atrium, yielding a controlled model of atrial septostomy. Data were obtained 1) preshunt or “CPH”; 2) “Low-Flow” shunt; and 3) “High-Flow” shunt (occluding superior vena cava forcing all flow through the shunt). With progressive shunting, right ventricular pressure fell from 72 ± 19 mmHg (CPH) to 54 ± 17 mmHg (Low-Flow) and 47 ± 17 mmHg (High-Flow) ( P < 0.001). Cardiac output increased from 1.5 ± 0.3 l/min at CPH to 1.8 ± 0.4 l/min at Low-Flow (286 ± 105 ml/min, 15% of cardiac output; P < 0.001), but returned to 1.6 ± 0.3 l/min at High-Flow (466 ± 172 ml/min, 29% of cardiac output; P = 0.008 vs. Low-Flow, P = 0.21 vs. CPH). There was a modest rise in systemic oxygen delivery from 252 ± 46 ml/min at CPH to 276 ± 50 ml/min at Low-Flow ( P = 0.07), but substantial fall to 222 ± 50 ml/min at High-Flow ( P = 0.005 vs. CPH, P < 0.001 vs. Low-Flow). With progressive shunting, bichamber contractility did not change ( P = 0.98), but the slope of the right atrial end-diastolic pressure volume relation decreased ( P < 0.04), consistent with improved compliance. This study demonstrated that Low-Flow interatrial shunting consistently improved right atrial mechanics and systemic perfusion in subjects with CPH, while High-Flow exceeded an “ideal shunt fraction”.


2008 ◽  
Vol 27 (12) ◽  
pp. 1711-1716 ◽  
Author(s):  
Hong-Mao Chen ◽  
Yun-You Duan ◽  
Li-Jun Yuan ◽  
Ning Zhou ◽  
Juan Li ◽  
...  

2011 ◽  
Vol 28 (9) ◽  
pp. 941-947 ◽  
Author(s):  
Dan Dan Sun ◽  
Hong Mao Chen ◽  
Yun You Duan ◽  
Li Jun Yuan ◽  
Fu Jun Shang ◽  
...  

Respiration ◽  
2003 ◽  
Vol 70 (2) ◽  
pp. 207-210 ◽  
Author(s):  
Mauro Maniscalco ◽  
Giovanni Dialetto ◽  
Giovanni Tufano ◽  
Annamaria Romano ◽  
Matteo Sofia

2018 ◽  
Vol 99 (1) ◽  
pp. 47-48 ◽  
Author(s):  
M. Demeyere ◽  
D. Delacour ◽  
F. Bouchart ◽  
P. Michelin ◽  
F. Bauer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document