DEVELOPMENT OF THE CROSS-FLOW TEST FACILITY CONSISTING OF TWO SUBCHANNELS UNDER BOILING WATER REACTOR CONDITIONS

Author(s):  
Masaki Ikeda ◽  
Kiyoshi Fujimoto ◽  
Hideaki Hosoi ◽  
Kenichi Katono ◽  
Kenichi Yasuda ◽  
...  
Author(s):  
Tsutomu Shioyama ◽  
Masashi Nakane ◽  
Takuya Miyagawa ◽  
Makoto Ukai ◽  
Masanobu Watanabe ◽  
...  

The purpose of this study is to identify hydrodynamic loads due to steam condensation acting on the Suppression Pool (S/P) in Primary Containment Vessel (PCV) of Advanced-Boiling Water Reactor (ABWR) by using general-purpose analysis code, ANSYS™. The source load methodology has been used to evaluate the hydrodynamic loads, which are classified into condensation oscillation (CO) and chugging (CH). When setting the design source from the confirmation test, the calculation method due to the eigenfunction of the cylindrical coordinate system was used. Since, there were various limitations in the previous approaches, a new analysis approach has been expected. In this study, the pool of ABWR horizontal-vent confirmatory test facility is modeled with the ANSYS™ acoustic elements. The calculation results are in good agreement with the test pressure oscillations. It is confirmed that the proposed approach can create the design source enveloping the PSD of test results.


2014 ◽  
Vol 2014 (1) ◽  
pp. 17-22
Author(s):  
Abdelfettah Benchrif ◽  
◽  
Abdelouahed Chetaine ◽  
Hamid Amsil ◽  
◽  
...  

Author(s):  
Antonella Lombardi Costa ◽  
WILMER ARUQUIPA COLOMA ◽  
Antonella Lombardi Costa ◽  
Claubia Pereira ◽  
Maria Veloso ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document