scholarly journals High-Throughput Multiplexed T-Cell–Receptor Excision Circle Quantitative PCR Assay with Internal Controls for Detection of Severe Combined Immunodeficiency in Population-Based Newborn Screening

2010 ◽  
Vol 56 (9) ◽  
pp. 1466-1474 ◽  
Author(s):  
Jacalyn L Gerstel-Thompson ◽  
Jonathan F Wilkey ◽  
Jennifer C Baptiste ◽  
Jennifer S Navas ◽  
Sung-Yun Pai ◽  
...  

BACKGROUND Real-time quantitative PCR (qPCR) targeting a specific marker of functional T cells, the T-cell–receptor excision circle (TREC), detects the absence of functional T cells and has a demonstrated clinical validity for detecting severe combined immunodeficiency (SCID) in infants. There is need for a qPCR TREC assay with an internal control to monitor DNA quality and the relative cellular content of the particular dried blood spot punch sampled in each reaction. The utility of the qPCR TREC assay would also be far improved if more tests could be performed on the same newborn screening sample. METHODS We approached the multiplexing of qPCR for TREC by attenuating the reaction for the reference gene, with focus on maintaining tight quality assurance for reproducible slopes and for prevention of sample-to-sample cross contamination. Statewide newborn screening for SCID using the multiplexed assay was implemented, and quality-assurance data were recorded. RESULTS The multiplex qPCR TREC assay showed nearly 100% amplification efficiency for each of the TREC and reference sequences, clinical validity for multiple forms of SCID, and an analytic limit of detection consistent with prevention of contamination. The eluate and residual ghost from a 3.2-mm dried blood spot could be used as source material for multiplexed immunoassays and multiplexed DNA tests (Multiplex Plus), with no disruption to the multiplex TREC qPCR. CONCLUSIONS Population-based SCID newborn screening programs should consider multiplexing for quality assurance purposes. Potential benefits of using Multiplex Plus include the ability to perform multianalyte profiling.

Author(s):  
J. Robert Thompson ◽  
Cheryl R. Greenberg ◽  
Andrew Dick ◽  
Olga Jilkine ◽  
Luvinia Kwan ◽  
...  

The incidence of Severe Combined Immunodeficiency (SCID) in Manitoba, (1/15,000), is at least three to four times higher than the national average and that reported from other jurisdictions. It is overrepresented in two population groups: Mennonites (ZAP70 founder mutation) and First Nations of Northern Cree ancestry (IKBKB founder mutation). We have previously demonstrated that in these two populations the most widely utilized T-cell receptor excision circle (TREC) assay is an ineffective newborn screening test to detect SCID as these patients have normal numbers of mature T-cells. We have developed a semi-automated, closed tube, high resolution DNA melting procedure to simultaneously genotype both of these mutations from the same newborn blood spot DNA extract used for the TREC assay. Parallel analysis of all newborn screening specimens utilizing both TREC analysis and the high resolution DNA procedure should provide as complete ascertainment as possible of SCID in the Manitoba population.


2021 ◽  
Vol 7 (3) ◽  
pp. 43
Author(s):  
Michael F. Cogley ◽  
Amy E. Wiberley-Bradford ◽  
Sean T. Mochal ◽  
Sandra J. Dawe ◽  
Zachary D. Piro ◽  
...  

All newborn screening programs screen for severe combined immunodeficiency by measurement of T-cell receptor excision circles (TRECs). Herein, we report our experience of reporting TREC assay results as multiple of the median (MoM) rather than using conventional copy numbers. This modification simplifies the assay by eliminating the need for standards with known TREC copy numbers. Furthermore, since MoM is a measure of how far an individual test result deviates from the median, it allows normalization of TREC assay data from different laboratories, so that individual test results can be compared regardless of the particular method, assay, or reagents used.


2021 ◽  
Vol 7 (4) ◽  
pp. 74
Author(s):  
Maartje Blom ◽  
Robbert G. M. Bredius ◽  
Mirjam van der Burg

Newborn screening (NBS) programs continue to expand due to innovations in both test methods and treatment options. Since the introduction of the T-cell receptor excision circle (TREC) assay 15 years ago, many countries have adopted screening for severe combined immunodeficiency (SCID) in their NBS program. SCID became the first inborn error of immunity (IEI) in population-based screening and at the same time the TREC assay became the first high-throughput DNA-based test in NBS laboratories. In addition to SCID, there are many other IEI that could benefit from early diagnosis and intervention by preventing severe infections, immune dysregulation, and autoimmunity, if a suitable NBS test was available. Advances in technologies such as KREC analysis, epigenetic immune cell counting, protein profiling, and genomic techniques such as next-generation sequencing (NGS) and whole-genome sequencing (WGS) could allow early detection of various IEI shortly after birth. In the next years, the role of these technical advances as well as ethical, social, and legal implications, logistics and cost will have to be carefully examined before different IEI can be considered as suitable candidates for inclusion in NBS programs.


2018 ◽  
Vol 38 (7) ◽  
pp. 778-786 ◽  
Author(s):  
Marie A. P. Audrain ◽  
Alexandra J. C. Léger ◽  
Caroline A. F. Hémont ◽  
Sophie M. Mirallié ◽  
David Cheillan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document