scholarly journals Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation

2018 ◽  
Vol 64 (5) ◽  
pp. 820-829 ◽  
Author(s):  
Jaimi Greenslade ◽  
Elizabeth Cho ◽  
Christopher Van Hise ◽  
Tracey Hawkins ◽  
William Parsonage ◽  
...  

Abstract BACKGROUND Low concentrations of cardiac troponin (cTn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (hs-cTnI) assay to identify a single test threshold that can safely rule out AMI. METHODS This analysis used stored samples collected in 2 prospective observational studies. In all, 1871 patients presenting to a tertiary emergency department with symptoms of acute coronary syndrome had blood taken for measurement of cTnI on presentation. The endpoint was type 1 myocardial infarction (T1MI). Sensitivity and negative predictive value (NPV) were calculated for hs-cTnI values below the 99th percentile. RESULTS Ninety-eight patients had T1MI (5.2%), and 638 (34.1%) patients had an hs-cTnI <2 ng/L (limit of detection), with sensitivity of 99.0% (95% CI, 94.4%–100%) and NPV of 99.8% (95% CI, 99.1%–100%). No hs-cTnI value above a concentration of 2 ng/L achieved sensitivity of 99%. However, an NPV of 99.5% was achieved at values <6 ng/L. A cutoff <6 ng/L enabled 1475 (78.8%) patients to be ruled out on presentation with sensitivity of 93.9% (95% CI, 87.1%–97.7%). CONCLUSIONS A single baseline cTn <2 ng/L measured with the Access hs-cTnI assay performed well for rule-out of AMI. This cutoff concentration identified 99% of patients with AMI and could reduce the number of patients requiring lengthy assessment. A cutoff of <6 ng/L yielded a high NPV but missed more cases of AMI than would be acceptable to clinicians.

Circulation ◽  
2017 ◽  
Vol 135 (17) ◽  
pp. 1597-1611 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
Patrick Badertscher ◽  
...  

2016 ◽  
Vol 171 (1) ◽  
pp. 92-102.e5 ◽  
Author(s):  
Cedric Jaeger ◽  
Karin Wildi ◽  
Raphael Twerenbold ◽  
Tobias Reichlin ◽  
Maria Rubini Gimenez ◽  
...  

Heart ◽  
2018 ◽  
pp. heartjnl-2018-314093 ◽  
Author(s):  
Andrew R Chapman ◽  
Takeshi Fujisawa ◽  
Kuan Ken Lee ◽  
Jack Patrick Andrews ◽  
Atul Anand ◽  
...  

BackgroundHigh-sensitivity cardiac troponin assays enable the early risk stratification of patients with suspected acute coronary syndrome to identify those at low risk of myocardial infarction or cardiac death. We evaluated the performance of a novel high-sensitivity cardiac troponin I assay in early rule out pathways.MethodsIn 1920 patients with suspected acute coronary syndrome, cardiac troponin was measured using the Siemens Atellica high-sensitivity cardiac troponin I assay (99th centile: 34 ng/L women, 53 ng/L men). We evaluated three pathways which use either low risk-stratification thresholds of cardiac troponin (High-SensitivityTroponin in the Evaluation of patients with Acute Coronary Syndrome (High-STEACS) and the European Society of Cardiology (ESC) 1 hour pathway) or the 99th centile diagnostic threshold (ESC 3 hour pathway) to rule out myocardial infarction.ResultsThe primary outcome of myocardial infarction or cardiac death at 30 days occurred in 14.4% (277/1920). The High-STEACS pathway ruled out 63% of patients (1218/1920), with five missed events for a negative predictive value (NPV) of 99.5% (95% CI (CI) 99.1% to 99.8%). Similar performance was observed for the ESC 1 hour pathway with an NPV of 99.0% (97.6% to 99.8%). In contrast, the ESC 3 hour pathway ruled out 65% of patients (1248/1920), but missed 25 events for an NPV of 98.0% (97.1% to 98.7%).ConclusionsA novel high-sensitivity cardiac troponin I assay can safely identify patients at low risk of myocardial infarction or cardiac death. Diagnostic pathways that use low cardiac troponin concentrations for risk stratification miss fewer events than those that rely on the 99th centile to rule out myocardial infarction.Trial registrationNCT1852123.


2015 ◽  
Vol 128 (8) ◽  
pp. 861-870.e4 ◽  
Author(s):  
Maria Rubini Gimenez ◽  
Raphael Twerenbold ◽  
Cedric Jaeger ◽  
Christian Schindler ◽  
Christian Puelacher ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document