16 Hydrogen distribution infrastructure

2021 ◽  
pp. 491-510
Author(s):  
Paul E. Dodds ◽  
Daniel Scamman ◽  
Paul Ekins
2021 ◽  
pp. 149331
Author(s):  
Mohan Kumar Kuntumalla ◽  
Mohammed Attrash ◽  
Miri Fischer ◽  
Shaul Michaelson ◽  
Tatyana Kravchuk ◽  
...  

Author(s):  
Pal Kostka ◽  
Zsolt Techy ◽  
James J. Sienicki

Hydrogen combustion may represent a threat to containment integrity in a VVER-440/213 plant owing to the combination of high pressure and high temperature. A study has been carried out using the GASFLOW 2.1 three-dimensional CFD code to evaluate the hydrogen distribution in the containment during a beyond design basis accident. The VVER-440/213 containment input model consists of two 3D blocks connected via one-dimensional (1D) ducts. One 3D block contains the reactor building and the accident localization tower with the suppression pools. Another 3D block models the air traps. 1D ducts represent the check valves connecting the accident localization tower with the air traps. The VVER pressure suppression system, called “bubbler condenser,” was modeled as a distributed heat sink with water thermodynamic properties. This model accounts for the energy balance. However, it is not currently possible to model dynamic phenomena associated with the water pools (e.g., vent clearing, level change). The GASFLOW 2.1 calculation gave detailed results for the spatial distribution of thermal-hydraulic parameters and gas concentrations. The range and trend of the parameters are reasonable and valuable. There are particularly interesting circulation patterns around the steam generators, in the bubbler tower and other primary system compartments. In case of the bubbler tower, concentration and temperature contour plots show an inhomogeneous distribution along the height and width, changing during the accident. Hydrogen concentrations also vary within primary system compartments displaying lower as well as higher (up to 13–20% and higher) values in some nodes. Prediction of such concentration distributions was not previously possible with lumped parameter codes. GASFLOW 2.1 calculations were compared with CONTAIN 1.2 (lumped parameter code) results. Apart from the qualitatively similar trends, there are, for the time being, quantitative differences between the results concerning, for example, pressure histories, or the total amount of steam available in the containment. The results confirm the importance of detailed modeling of the containment, as well as of the bubbler condenser and sump water pools. The study showed that modeling of hydrogen distribution in the VVER-440/213 containment was possible using the GASFLOW 2.1 code with reasonable results and remarkable physical insights.


Author(s):  
Svetlin Philipov ◽  
Kalin Filipov

This paper presents the results of an analysis of the application of CFD tool to help hydrogen management. Some information pointed out the problem of hydrogen generation and distribution. Passive autocatalytic recombiners are the point of interest and mainly PAR units’ location. A severe accident is taken into account regarding the sources of hydrogen generation. The analysis of the severe accident progression is performed with MELCOR code. CFD tool Fluent (ANSYS) is applied to assess hydrogen and steam distribution in the atmosphere of the containment (confinement). The NPP unit of type WWER 440 (V230) is considered but as it is stressed this fact is irrelevant to phenomena and accident management targets.


2010 ◽  
Vol 88 (10) ◽  
pp. 723-728 ◽  
Author(s):  
H. Fritzsche ◽  
E. Poirier ◽  
J. Haagsma ◽  
C. Ophus ◽  
E. Luber ◽  
...  

In this article, we show how neutron reflectometry (NR) can provide deep insight into the absorption and desorption properties of commercially promising hydrogen storage materials. NR benefits from the large negative scattering length of hydrogen atoms, which changes the reflectivity curve substantially, so that NR can determine not only the total amount of stored hydrogen but also the hydrogen distribution along the film normal, with nanometer resolution. To use NR, the samples must have smooth surfaces, and the film thickness should range between 10 and 200 nm. We performed a systematic study on thin Mg1–xAlx alloy films (x = 0.2, 0.3, 0.4, 0.67) capped with a Pd catalyst layer. Our NR experiments showed that Mg0.7Al0.3 is the optimum alloy composition with the highest amount of stored hydrogen and the lowest desorption temperature. All the thin films expand by about 20% because of hydrogen absorption, and the hydrogen is stored only in the MgAl layer with no hydrogen content in the Pd layer.


Sign in / Sign up

Export Citation Format

Share Document