scholarly journals Determination of Ammonium Concentration in Post-Process Waters from Underground Coal Gasification

2016 ◽  
Vol 21 (1-2) ◽  
pp. 107-116
Author(s):  
Malwina Cykowska ◽  
Małgorzata Bebek ◽  
Aleksandra Strugała-Wilczek

AbstractA flow injection analysis method for spectrophotometric determination of ammonium in waters produced during underground coal gasification (UCG) of lignite and hard coal was described. The analysis of UCG water samples is very difficult because of their very complicated matrix and colour. Due to a huge content of organic and inorganic substances and intensive colour of samples (sometimes yellow, quite often dark brown or even black), most analytical methods are not suitable for practical application. Flow injection analysis (FIA) is based on diffusion of ammonia through a hydrophobic gas permeable membrane from an alkaline solution stream into an acid-base indicator solution stream. Diffused ammonia causes a colour change of indicator solution, and ammonia is subsequently quantified spectrophotometrically at 590 nm wavelength. The reliability of the results provided by applied method was evaluated by checking validation parameters like accuracy and precision. Accuracy was evaluated by recovery studies using multiple standard addition method. Precision as repeatability was expressed as a coefficient of variation (CV).

Soil Research ◽  
1996 ◽  
Vol 34 (4) ◽  
pp. 503 ◽  
Author(s):  
AMR Ferreira ◽  
J Lima ◽  
A Rangel

A flow injection analysis (FIA) system incorporating a gas-diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas-permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2-ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always < 5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation < 3%).


The Analyst ◽  
1988 ◽  
Vol 113 (2) ◽  
pp. 317-319 ◽  
Author(s):  
Cristina Latorre ◽  
Manuel Hernández Blanco ◽  
Encarna Lorenzo Abad ◽  
Jose Vicente ◽  
Lucas Hernández

Sign in / Sign up

Export Citation Format

Share Document