A New Adaptive Differential Protection Scheme for Tap Changing Power Transformer

2015 ◽  
Vol 16 (4) ◽  
pp. 339-348 ◽  
Author(s):  
Ashesh Mukeshbhai Shah ◽  
Bhavesh Bhalja

Abstract This paper presents a new adaptive differential protection scheme which efficiently adapts the change in tap position of a power transformer. The proposed scheme is based on analytical derivation of pick-up and slope of the differential relay characteristic. By acquiring information such as rating & connection of CTs and present tap position as input, the proposed scheme enhances sensitivity of differential relay during internal faults. This is accomplished either by decreasing pick-up and/or adjusting slope of the differential characteristic of the relay in case of change in tap position. Numerous test cases consisting of various types of internal and external faults have been simulated for an existing power transformer of Gujarat Energy Transmission Corporation Limited (GETCO), Gujarat, India using PSCAD/EMTDC software package. The proposed scheme increases percentage of winding to be protected during internal faults for power transformers having different ratings and connections compared to the conventional differential protection scheme. Furthermore, it has been observed that the detection sensitivity during special types of turn-to-turn and inter-winding faults with varying fault resistances is also enhanced compared to the conventional scheme. Moreover, it equally maintains stability during CT saturation condition. At the end, comparative evaluation of the proposed scheme with the existing schemes clearly indicates superiority of the proposed adaptive scheme.

2019 ◽  
Vol 8 (3) ◽  
pp. 7627-7630

This paper presents wavelet transform method for the analysis of differential currents of power transformer which can act as an accurate classifier between magnetizing inrush current and internal faults to avoid the needless tripping of circuit breaker. The differential protection scheme occasionally mal – operate whenever magnetizing inrush occurs in power transformer. The aim is to reduce the rate and time duration of undesired outages of power transformer. This includes the necessities of reliability with zero mal – operation of differential relay. The result shows higher operating speed with less fault clearing time. Wavelet Transform is employed for the analysis of transient signals under various conditions, which extracts data from signals in time and frequency domain simultaneously. The simulation is done in MATLAB environment.


2008 ◽  
Vol 71 (4-6) ◽  
pp. 904-918 ◽  
Author(s):  
M. Geethanjali ◽  
S. Mary Raja Slochanal ◽  
R. Bhavani

2020 ◽  
Vol 87 ◽  
pp. 105975 ◽  
Author(s):  
Shahabodin Afrasiabi ◽  
Mousa Afrasiabi ◽  
Benyamin Parang ◽  
Mohammad Mohammadi

2019 ◽  
Vol 13 (12) ◽  
pp. 2423-2437 ◽  
Author(s):  
Arpita Roy ◽  
Devender Singh ◽  
Rakesh Kumar Misra ◽  
Amit Singh

Sign in / Sign up

Export Citation Format

Share Document