inrush current
Recently Published Documents


TOTAL DOCUMENTS

796
(FIVE YEARS 213)

H-INDEX

29
(FIVE YEARS 4)

Author(s):  
Yuanlin Pan ◽  
Xin Yin ◽  
Xianggen Yin ◽  
Zhe Zhang ◽  
Lin Jiang ◽  
...  

2022 ◽  
Vol 8 ◽  
pp. 1257-1263
Author(s):  
Yuanlin Pan ◽  
Zhichang Liu ◽  
Xin Yin ◽  
Wei Xi ◽  
Xianggen Yin ◽  
...  

2021 ◽  
Vol 16 ◽  
pp. 308-315
Author(s):  
Ziyad S. Almajali

or successful transformer differential protection employment, correct discrimination between inrush current and fault current is essential. It is one of the main focuses of research and one of the main challenges for transformer protection. In this paper, a discrimination method based on utilizing chromatic monitoring of the box dimension algorithm outcome curve for transformer differential current in time-domain analysis is proposed. The x-L chromatic mapping is employed for general detection of fault cases, while the x-y chromatic mapping result is used for distinguishing inrush current from the fault current cycles. The preliminary results show that the proposed method can effectively provide correct discrimination of the current type within quite a short time and thus help in providing efficient decision-making supportive protection tool.


Author(s):  
Fangcen Zhong ◽  
Masanori NATSUI ◽  
Takahiro Hanyu

Abstract Nonvolatile large-scale integrated circuits (NV-LSIs) with a power-gating (PG) technique can drastically reduce the wasted static power consumption, which is an attractive feature in Internet-of-Things (IoT) edge devices. However, the issues of inrush current and voltage fluctuation due to PG-state transitions are preventing their advancement. This paper describes a technique for stabilizing the operation of NV-LSIs during PG by minimizing inrush current effects and voltage fluctuations. In the proposed technique, several PG switch configurations are prepared and one of them are dynamically selected in accordance with the expected operation conditions, which could minimize inrush current and voltage fluctuations in the power supply. This technique is applied to sub-array-level PG of a spin-transfer torque magneto-resistive random-access memory (STT-MRAM). As a result, inrush current level and the recovery time of the power supply from a sleep state are reduced by up to 83.8% and 68.7%, respectively, while satisfying given performance requirements.


2021 ◽  
Vol 12 (4) ◽  
pp. 286-291
Author(s):  
V. P. Vasilevich ◽  
M. V. Zbyshinskaya

The main reason of voltage instability in stand-alone power supply systems is the electric drive motors inrush current, which are usually higher than their nominal value. The most reasonable way to solve this problem is using capacitive energy storage. The purpose of research is shape and measurement monitoring of battery-capacitive energy storage device inrush current characteristics. Parameters comparative analysis for lithium-ion battery (LIB) part and capacitive part of the energy storage device was holding with the twochannel digital oscilloscope.Measuring testing bench included parallel connected LIB part and capacitive part of the storage device and connected to the power source. The LIB part of the storage device is made on the basis of the ATOM 10 multifunctional motor drive device of the new generation, which contains 15 V lithium-ion battery and 9.4 A·h capacity. The capacitive part of the storage device is the INSPECTOR Booster supercapacitor with an 80 F electrostatic capacitance and 15.5 V voltage. A 12 V AC/DC step-down converter was used as a power source. An electric air automobile compressor M-14001 was used as a current drain. The testing bench measuring part consisted of a two-channel digital oscilloscope and two standard measuring shunts with 15000 μOm resistance serial attached to LIB part and capacitive part of the storage device. Shape and measurement monitoring of inrush current characteristics of LIB part and capacitive part of the energy storage device was held synchronously using a two-channel digital oscilloscope with recording data to FAT32 file system USB flash drive. Obtained data was transferred to a personal computer and analyzed.The measurement results showed that 82.3 % of the energy losses compensation of the motor start is taken over by the capacitive part of the energy storage device, what makes longer LIB’s life. By adjusting the oscilloscope sweep trace index you can analyze more detailed time response shape and its duration. The values of the inrush current amplitudes were calculated in proportion to the voltage drop on the shunts and their resistances.The developed method for monitoring shape and measurement inrush current characteristics can be used in various technical applications: smart stand-alone photovoltaic system, uninterruptible power supply devices, electric drive control systems, etc.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8284
Author(s):  
Abdul Azeem ◽  
Majid Jamil ◽  
Shamimul Qamar ◽  
Hasmat Malik ◽  
Rayees Ahmad Thokar

In this paper, the authors have developed a hardware model for blocking even and odd harmonics of a power transformer. In the proposed hardware model, intelligent differential & over-current relays are used for the blocking of harmonics of a power transformer. The harmonic restraint function on the differential relay (7UT61) prevents the relay from tripping during transformer magnetizing inrush current. However, the over-current relays which are used for back up protection does not have a harmonic restraint element, and over-current relay trips due to magnetizing inrush current, causes unwanted interruptions and power failures. The establishment of harmonic blocking scheme for over-current protection in power transformers is an important finding of this research study. IEC61850 standard-Based GOOSE (Generic Object Oriented Substation Event) applications used in power transformer protection for fast detecting and clearing of faults is an interested study presented in the proposed work.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8244
Author(s):  
Wenqi Ge ◽  
Chenchen Zhang ◽  
Yi Xie ◽  
Ming Yu ◽  
Youhua Wang

When the electromagnetic transients occur in a power transformer, an inrush current is generated in its winding. The inrush current not only affects the performance of the transformer windings, but also affects the lifetime of the transformer. Many factors affect the inrush current, the most influential ones among which are the closing phase angle and the residual flux. In this paper, a dry-type transformer simulation model is built to analyze the influence of the inrush current on the performance of transformer windings during no-load reclosing conditions. Firstly, the inrush current was generated in the transformer windings during the no-load reclosing operation under different residual fluxes. Secondly, the field-circuit coupling 3d finite element method is used to analyze the electromagnetic force at different locations of the transformer windings under the influence of different inrush currents. The results of winding structural parameter variations are obtained through electromagnetic-structural coupling simulation, and the electromagnetic forces are used as the input parameter for the structural analysis. Finally, the residual flux is generated by controlling the opening and closing angle of the transformer through the phase-controlled switch, and the winding electromechanical characteristics are tested under different residual fluxes. Finally, comparisons of the test and simulation results are drawn to verify the impact of the closing angle and residual flux on inrush current and the winding deformation during the no-load reclosing conditions.


2021 ◽  
Author(s):  
Mahdi Karimi ◽  
Paria Kargar ◽  
Kazem Varesi ◽  
Sze Sing Lee
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document