detection sensitivity
Recently Published Documents


TOTAL DOCUMENTS

1930
(FIVE YEARS 786)

H-INDEX

61
(FIVE YEARS 12)

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 638
Author(s):  
Hima Zafar ◽  
Asma Channa ◽  
Varun Jeoti ◽  
Goran M. Stojanović

The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.


2022 ◽  
Author(s):  
Revanth Reddy ◽  
Liwei Yang ◽  
Jesse Liu ◽  
Zhuojie Liu ◽  
Jun Wang

Highly multiplexed analysis of biospecimens significantly advances the understanding of biological basics of diseases, but these techniques are limited by the number of multiplexity and the speed of processing. Here, we present a rapid multiplex method for quantitative detection of protein markers on brain sections with the cellular resolution. This spatial multiplex in situ tagging (MIST) technology is built upon a MIST microarray that contains millions of small microbeads carrying barcoded oligonucleotides. Using antibodies tagged with UV cleavable oligonucleotides, the distribution of protein markers on a tissue slice could be printed on the MIST microarray with high fidelity. The performance of this technology in detection sensitivity, resolution and signal-to-noise level has been fully characterized by detecting brain cell markers. We showcase the codetection of 31 proteins simultaneously within 2 h which is about 10 times faster than the other immunofluorescence-based approaches of similar multiplexity. A full set of computational toolkits was developed to segment the small regions and identify the regional differences across the entire mouse brain. This technique enables us to rapidly and conveniently detect dozens of biomarkers on a tissue specimen, and it can find broad applications in clinical pathology and disease mechanistic studies.


Author(s):  
Binfang Wu ◽  
Haitao Xu ◽  
Yufeng Shi ◽  
Zhijie Yao ◽  
Jiayu Yu ◽  
...  

Abstract Microelectrode glucose biosensor based on three-dimensional hybrid nanoporous platinum/graphene oxide nanostructure was developed for rapid glucose detection of tomato and cucumber fruits. The nanostructure was fabricated by a two-step modification method on microelectrode for loading a larger amount of glucose oxidase. The nanoporous structure was prepared on the surface of the platinum microelectrode by electrochemical etching, and then graphene oxide was deposited on the prepared nanoporous electrode by electrochemical deposition. The nanoprorous platinum/graphene oxide nanostructure had the advantage of improving the effective surface area of the electrode and the loading quantity of glucose oxidase. As a result, the biosensor achieved a wide range of 0.1-20.0 mM in glucose detection, which had the ability to accurately detect the glucose content. It was found that the three-dimensional hybrid nanostructure on the electrode surface realized the rapid direct electrochemistry of glucose oxidase. Therefore, the biosensor achieved high glucose detection sensitivity (11.64 μA mM -1cm -2), low detection limit (13 μM) and rapid response time (reaching 95% steady-state response within 3 seconds), when calibrating in glucose standard solution. In agricultural application, the as-prepared biosensor was employed to detect the glucose concentration of tomato and cucumber samples. The results showed that the relative deviation of this method was less than 5% when compared with that of HPLC, implying high accuracy of the presented biosensor in glucose detection in plants.


2022 ◽  
Vol 9 (1) ◽  
pp. 17
Author(s):  
Bartosz Krzowski ◽  
Jakub Rokicki ◽  
Renata Główczyńska ◽  
Nikola Fajkis-Zajączkowska ◽  
Katarzyna Barczewska ◽  
...  

Background: Cardiovascular disease remains the leading cause of death in the European Union and worldwide. Constant improvement in cardiac care is leading to an increased number of patients with heart failure, which is a challenging condition in terms of clinical management. Cardiac resynchronization therapy is becoming more popular because of its grounded position in guidelines and clinical practice. However, some patients do not respond to treatment as expected. One way of assessing cardiac resynchronization therapy is with ECG analysis. Artificial intelligence is increasing in terms of everyday usability due to the possibility of everyday workflow improvement and, as a result, shortens the time required for diagnosis. A special area of artificial intelligence is machine learning. AI algorithms learn on their own based on implemented data. The aim of this study was to evaluate using artificial intelligence algorithms for detecting inadequate resynchronization therapy. Methods: A total of 1241 ECG tracings were collected from 547 cardiac department patients. All ECG signals were analyzed by three independent cardiologists. Every signal event (QRS-complex) and rhythm was manually classified by the medical team and fully reviewed by additional cardiologists. The results were divided into two parts: 80% of the results were used to train the algorithm, and 20% were used for the test (Cardiomatics, Cracow, Poland). Results: The required level of detection sensitivity of effective cardiac resynchronization therapy stimulation was achieved: 99.2% with a precision of 92.4%. Conclusions: Artificial intelligence algorithms can be a useful tool in assessing the effectiveness of resynchronization therapy.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Juan D. Rojas ◽  
Jordan B. Joiner ◽  
Brian Velasco ◽  
Kathlyne Jayne B. Bautista ◽  
Adam M. Aji ◽  
...  

AbstractPreclinical mouse solid tumor models are widely used to evaluate efficacy of novel cancer therapeutics. Recent reports have highlighted the need for utilizing orthotopic implantation to represent clinical disease more accurately, however the deep tissue location of these tumors makes longitudinal assessment challenging without the use of imaging techniques. The purpose of this study was to evaluate the performance of a new multi-modality high-throughput in vivo imaging system that combines bioluminescence imaging (BLI) with robotic, hands-free ultrasound (US) for evaluating orthotopic mouse models. Long utilized in cancer research as independent modalities, we hypothesized that the combination of BLI and US would offer complementary advantages of detection sensitivity and quantification accuracy, while mitigating individual technological weaknesses. Bioluminescent pancreatic tumor cells were injected into the pancreas tail of C57BL/6 mice and imaged weekly with the combination system and magnetic resonance imaging (MRI) to serve as a gold standard. BLI photon flux was quantified to assess tumor activity and distribution, and US and MRI datasets were manually segmented for gross tumor volume. Robotic US and MRI demonstrated a strong agreement (R2 = 0.94) for tumor volume measurement. BLI showed a weak overall agreement with MRI (R2 = 0.21), however, it offered the greatest sensitivity to detecting the presence of tumors. We conclude that combining BLI with robotic US offers an efficient screening tool for orthotopic tumor models.


2022 ◽  
Author(s):  
Yueting Zhou ◽  
Gang Zhao ◽  
Jianxin Liu ◽  
Xiaojuan Yan ◽  
Zhixin Li ◽  
...  

Abstract The laser frequency could be linked to an radio frequency through an external cavity by the combination of Pound-Drever-Hall and Devoe-Brewer locking techniques. A stable and tunable optical frequency at wavelength of 1.5 μm obtained by a cavity with high finesse of 96,000 and a fiber laser, calibrated by a commercial optical frequency comb, has been demonstrated. The locking performances have been analyzed by in-loop and out-loop noises, indicating that the absolute frequency instability could be down to 50 kHz over 1 s and keep to less than 110 kHz over 2.5 h. Then, the application of this stabilized laser to the direct absorption spectroscopy has been performed. With the help of balanced detection, the detection sensitivity, in terms of optical density, can reach to 9.4×10-6.


2022 ◽  
Vol 8 ◽  
Author(s):  
Huiting Yin ◽  
Shaohuang Chen ◽  
Renliang Huang ◽  
Heng Chang ◽  
Jiayue Liu ◽  
...  

Rapid detection of marine oil spills is becoming increasingly critical in the face of frequent marine oil spills. Oil slick thickness measurement is critical in the hazard assessment of such oil leaks. As surface plasmon resonance (SPR) sensors are sensitive to slight changes in refractive index, they can monitor offshore oil spills arising from significant differences in the refractive index between oil and water. This study presents a gold-film fiber-optic surface plasmon resonance (FOSPR) sensor prepared by polydopamine accelerated wet chemical plating for rapid and real-time measurement of oil slick thickness. We examined oil thickness detection at two interfaces, namely, water-oil and air-oil. Detection sensitivity of −1.373%/mm is obtained at the water-oil interface in the thickness range of 0–5 mm; detection sensitivity of −2.742%/mm is obtained at the air-oil interface in the thickness range of 0–10 mm. Temperature and salinity present negligible effects on the oil slick thickness measurement. The fabricated FOSPR sensor has the ability to detect the presence of oil as well as quantify the oil thickness. It has favorable repeatability and reusability, demonstrating the significant potential for use in the estimation of marine oil slick thickness.


2022 ◽  
Vol 9 ◽  
Author(s):  
Zhengqiong Dong ◽  
Hang Zhao ◽  
Lei Nie ◽  
Shaokang Tang ◽  
Chenyang Li ◽  
...  

The Morpho butterfly wing with tree-shaped alternating multilayer is an effective chemical biosensor to distinguish between ambient medium, and its detection sensitivity is inextricably linked to the measurement configuration including incident angle, azimuthal angle, and so on. In order to reveal the effects and the selection of measurement configuration. In this work, the model of the Morpho butterfly wing is built using the rigorous coupled-wave analysis method by considering its profile is a rectangular-groove grating. On basis of the above model, the reflectivity of different diffraction orders at a different incident angle and azimuthal angle is calculated, and the influence of incident angle and azimuthal angle on performance of Morpho butterfly scales-based biosensor is analyzed. The optimal incident angle at each azimuthal angle is given according to the proposed choice rule, then the azimuthal angle and the corresponding incident angle can be selected further.


eLife ◽  
2022 ◽  
Vol 11 ◽  
Author(s):  
Spencer Chin-Yu Chen ◽  
Giacomo Benvenuti ◽  
Yuzhi Chen ◽  
Satwant Kumar ◽  
Charu Ramakrishnan ◽  
...  

Can direct stimulation of primate V1 substitute for a visual stimulus and mimic its perceptual effect? To address this question, we developed an optical-genetic toolkit to 'read' neural population responses using widefield calcium imaging, while simultaneously using optogenetics to 'write' neural responses into V1 of behaving macaques. We focused on the phenomenon of visual masking, where detection of a dim target is significantly reduced by a co-localized medium-brightness mask [1, 2]. Using our toolkit, we tested whether V1 optogenetic stimulation can recapitulate the perceptual masking effect of a visual mask. We find that, similar to a visual mask, low-power optostimulation can significantly reduce visual detection sensitivity, that a sublinear interaction between visual and optogenetic evoked V1 responses could account for this perceptual effect, and that these neural and behavioral effects are spatially selective. Our toolkit and results open the door for further exploration of perceptual substitutions by direct stimulation of sensory cortex.


Sign in / Sign up

Export Citation Format

Share Document