scholarly journals Functional imaging by 11C-metomidate PET: a really useless technique for Primary Aldosteronism subtyping?

2021 ◽  
Author(s):  
Filippo Crimì ◽  
Alessandro Spimpolo ◽  
Diego Cecchin ◽  
Gian Paolo Rossi

Soinio et al. recently compared the diagnostic accuracy of 11C-metomidate PET (11C-MTO-PET) and cosyntropin-stimulated adrenal venous sampling (AVS) for the subtyping of patients with primary aldosteronism (PA), who were diagnosed according to the 2008 Endocrine Society guidelines. They concluded that 11C-MTO-PET offered no diagnostic usefulness in subtyping of PA patients. In our view, this conclusion needs to be taken with great caution owing to a number of concerns that can be raised concerning their study

2008 ◽  
Vol 55 (5) ◽  
pp. 839-846 ◽  
Author(s):  
Isao MINAMI ◽  
Takanobu YOSHIMOTO ◽  
Yuki HIRONO ◽  
Hajime IZUMIYAMA ◽  
Masaru DOI ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (7) ◽  
pp. e0253807
Author(s):  
Naohisa Tamura ◽  
Erika Watanabe ◽  
Rumi Shirakawa ◽  
Eiji Nakatani ◽  
Kanako Yamada ◽  
...  

Determining values of plasma renin activity (PRA) or plasma active renin concentration (ARC), plasma aldosterone concentration (PAC), and aldosterone-to-renin ratio (ARR) is essential to diagnose primary aldosteronism (PA), but it takes several days with conventional radioimmunoassays (RIAs). Chemiluminescent enzyme immunoassays for PAC and ARC using the Accuraseed® immunoanalyzer facilitated the determination, but relations between Accuraseed® immunoanalyzer-based and RIA-based values in samples of PA confirmatory tests and adrenal venous sampling remained to be elucidated. We addressed this issue in the present study. This is a prospective, cross-sectional study. ARC and PAC values were measured by the Accuraseed® immunoanalyzer in samples, in which PRA and PAC values had been measured by the PRA-FR® RIA and SPAC®-S Aldosterone kits, respectively. The relations between Accuraseed® immunoanalyzer-based and RIA-based values were investigated with regression analyses. The optimal cutoff of Accuraseed® immunoanalyzer-based ARR for PA screening was determined by the receiver operating characteristic analysis. After log-log transformations, linear relations with high coefficients of determination were observed between Accuraseed® immunoanalyzer-based and RIA-based data of renin and aldosterone. Following the PA guidelines of Japan Endocrine Society, Accuraseed® immunoanalyzer-based cutoffs were calculated from the regression equations: the basal PAC for PA screening >12 ng/dL, PAC for the saline infusion test >8.2 ng/dL, ARC for the furosemide-upright test <15 pg/mL, and ARR for the captopril challenge test >3.09 ng/dL per pg/mL. The optimal cutoff of Accuraseed® immunoanalyzer-based ARR for PA screening was >2.43 ng/dL over pg/mL not to overlook bilateral PA patients. The present study provided conversion formulas between Accuraseed® immunoanalyzer-based and RIA-based values of renin, aldosterone, and ARR, not only in basal samples but also in samples of PA confirmatory tests and adrenal venous sampling. Although validation studies are awaited, the present study will become priming water of harmonization of renin and aldosterone immunoassays.


2019 ◽  
Vol 34 (1) ◽  
pp. 34-42 ◽  
Author(s):  
Yuichi Fujii ◽  
◽  
Yoshiyu Takeda ◽  
Isao Kurihara ◽  
Hiroshi Itoh ◽  
...  

2011 ◽  
pp. P2-604-P2-604
Author(s):  
Akiyo Tanabe ◽  
Mika Tsuiki ◽  
Aya Tsumagari ◽  
Hitomi Kimura ◽  
Mitsuhide Naruse ◽  
...  

Author(s):  
Mirko Peitzsch ◽  
Tanja Dekkers ◽  
Matthias Haase ◽  
Fred C.G.J. Sweep ◽  
Ivo Quack ◽  
...  

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Chin-Chen Chang ◽  
Bo-Ching Lee ◽  
Kao-Lang Liu ◽  
Yeun-Chung Chang ◽  
Vin-Cent Wu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document