scholarly journals Ultrasound diagnosis of pulmonary sling with proximal stenosis of left pulmonary artery and patent arterial duct

2013 ◽  
Vol 13 (52) ◽  
pp. 104-110
Author(s):  
Wojciech Mądry ◽  
◽  
Maciej A. Karolczak ◽  
2020 ◽  
Vol 30 (2) ◽  
pp. 243-248 ◽  
Author(s):  
Sneha M. Jain ◽  
Priya M. Pradhan ◽  
Supratim Sen ◽  
Bharat V. Dalvi

AbstractObjective:To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.Introduction:Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.Method:This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.Results:Eighteen infants qualified for the study. Mean age and weight were 8.63 ± 3.84 months and 6.3 ± 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 ± 0.92 mm, and the mean duct length was 9.4 ± 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 ± 0.27, while the ratio of ductal length to device length was 1.48 ± 0.46 in those with successful outcome.Conclusions:Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.


1992 ◽  
Vol 2 (4) ◽  
pp. 335-337
Author(s):  
Luis Fernández Piñeda ◽  
Hugo Torrealday ◽  
Ramón Bermúdez Cañete ◽  
María J. Maitre Azcárate ◽  
Manuel Quero Jiménez

SummarySince February 1990, we have attempted nonsurgical occlusion of persistent patency of the arterial duct using the Rashkind double-disk occluding device, of either 12 or 17 mm diameter. Results are presented from 31 patients (23 female and eight male, ages 15 months to 16 years). M-Mode, cross-sectional, Doppler and color Doppler echocardiographic studies were made prior to closure, in the following 24 hours, and six months later. Left ventricular diastolic dimension and shortening fraction, systolic intervals, and left atrium/aortic ratio were evaluated by M-Mode echo. We examined carefully the location of the device relative to the left pulmonary artery and descending aorta, also checking for disturbed flows and residual shunts. These studies showed a clear tendency for the left ventricular diameter to decrease, and revealed a significant normalization of the left atrium/aortic ratio. Successful closure of the duct was achieved in 27 cases. Follow-up studies six months later showed residual shunting in four cases. In one patient, a second device was implanted with an excellent result. At the immediate follow-up, turbulences were noted in the area of the device (nine cases) and in the left pulmonary artery (seven cases). Distortion of the anatomic orientation of the left pulmonary artery was observed in three cases in which we discovered 20 mm Hg systolic gradients. In our opinion, echocardiography is the best technique with which to follow-up these patients. The high sensitivity of color Doppler echocardiography revealed minimal distortion of the left pulmonary artery, probably generated by regional anatomic adjustment to the insertion of the device.


2003 ◽  
Vol 13 (3) ◽  
pp. 302-304 ◽  
Author(s):  
Mervat Assaqqat ◽  
Ghassan Siblini ◽  
Fadel Al Fadley

We report a 12-year-old girl who had multiple congenital cardiac lesions, specifically an arterial duct, left pulmonary arterial stenosis, an atrial septal defect in the oval fossa, and mild Ebstein's malformation of the tricuspid valve. Therapeutic transcatheter intervention was performed to stent the left pulmonary artery, occlude the arterial duct with a coil, and place a device to close the atrial septal defect. Subsequent to the catheterization, she complained of hoarseness, which was shown to be due to entrapment of the left recurrent laryngeal nerve between the coil used to close the arterial duct and the stent placed in the left pulmonary artery. Laryngoscopy confirmed paralysis of the recurrent laryngeal nerve.


2016 ◽  
Vol 9 (3) ◽  
pp. 352-356
Author(s):  
Poonam P. Thankavel ◽  
Kristine J. Guleserian ◽  
Robert H. Anderson

We report two neonates with distal ductal origin of the left pulmonary artery who also had rare vascular rings comprised of a left aortic arch and right arterial duct with a midline/rightward descending aorta. To the best of our knowledge, this association has not previously been described, although other abnormalities of the left pulmonary artery in the setting of vascular rings have been reported. We review the embryology, utility of imaging, and clinical course.


The Lancet ◽  
1993 ◽  
Vol 341 (8844) ◽  
pp. 559-560 ◽  
Author(s):  
Fadel Fadley ◽  
Zohair Al-Halees ◽  
Omar Galal ◽  
Naresh Kumar ◽  
Neil Wilson

Sign in / Sign up

Export Citation Format

Share Document