patent arterial duct
Recently Published Documents


TOTAL DOCUMENTS

100
(FIVE YEARS 11)

H-INDEX

13
(FIVE YEARS 1)

Children ◽  
2021 ◽  
Vol 8 (12) ◽  
pp. 1138
Author(s):  
Mathilde Méot ◽  
Raymond N. Haddad ◽  
Juliana Patkai ◽  
Ibrahim Abu Zahira ◽  
Anna Di Marzio ◽  
...  

(1) Background: Transcatheter closure of the patent arterial duct (TCPDA) in preterm infants is an emerging procedure. Patent arterial duct (PDA) spontaneous closure after failed TCPDA attempts is seen but reasons and outcomes are not reported; (2) Methods: We retrospectively included all premature infants <2 kg with abandoned TCPDA procedures from our institutional database between September 2017 and August 2021. Patients’ data and outcomes were reviewed; (3) Results: The procedure was aborted in 14/130 patients referred for TCPDA. Two patients had spasmed PDA upon arrival in the catheterization laboratory and had no intervention. One patient had ductal spasm after guidewire cross. Four patients had unsuitable PDA size/shape for closure. In seven patients, device closure was not possible without causing obstruction on adjacent vessels. Among the 12 patients with attempted TCPDA, five had surgery on a median of 3 days after TCPDA and seven had a spontaneous PDA closure within a median of 3 days after the procedure. Only the shape of the PDA differed between the surgical ligation group (short and conical) and spontaneous closure group (F-type); (4) Conclusions: In the case of TCPDA failure, mechanically induced spontaneous closure may occur early after the procedure. Surgical ligation should be postponed when clinically tolerated.


2020 ◽  
Vol 7 (4) ◽  
pp. 43
Author(s):  
Diane E. Spicer ◽  
Thora S. Steffensen

Common arterial trunk is a rare anomaly on its own, but with an intact ventricular septum it is extremely rare. An unexpected finding at autopsy prompted a review of the literature and a review of the developmental considerations associated with the outflow tracts. The case presented was an intrauterine fetal death at 37 weeks gestation. At autopsy, the only anatomic abnormalities were pulmonary dominant common arterial trunk with an intact ventricular septum, ventriculo-arterial septal defect, coarctation and widely patent arterial duct. A review of the literature and the developmental concepts related to the outflow tracts of the developing heart demonstrate the rare nature of this particular variation of common arterial trunk.


2020 ◽  
Vol 8 ◽  
Author(s):  
Stephanie Haefeli ◽  
Marcin Kordasz ◽  
Catherine Tsai ◽  
Eva-Maria Hau ◽  
Peter Klimek ◽  
...  

2020 ◽  
Vol 30 (2) ◽  
pp. 243-248 ◽  
Author(s):  
Sneha M. Jain ◽  
Priya M. Pradhan ◽  
Supratim Sen ◽  
Bharat V. Dalvi

AbstractObjective:To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.Introduction:Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.Method:This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.Results:Eighteen infants qualified for the study. Mean age and weight were 8.63 ± 3.84 months and 6.3 ± 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 ± 0.92 mm, and the mean duct length was 9.4 ± 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 ± 0.27, while the ratio of ductal length to device length was 1.48 ± 0.46 in those with successful outcome.Conclusions:Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.


2019 ◽  
Vol 29 (11) ◽  
pp. 1410-1411
Author(s):  
Ondrej Materna ◽  
Vojtech Suchanek ◽  
Oleg Reich

AbstractA child undergoing routine transcatheter patent arterial duct closure developed severe transient ischemic changes in the electrocardiogram (Pardee waves) while the aortic retention skirt of the Amplatzer™ Duct Occluder was pulled against the duct orifice. The occluder was then released, and the delivery system was pulled back to inferior caval vein which led to electrocardiogram normalisation. Aortic root angiography showed a single coronary artery originating from the right sinus of Valsalva with the left coronary stem wedged behind the posterior aspect of the right ventricular outflow tract. We believe that the left coronary artery was compressed while applying tension on the occluder delivery system.


2019 ◽  
Vol 29 (11) ◽  
pp. 1397-1399
Author(s):  
Asish R. Mohakud ◽  
Sreeja Pavithran ◽  
Kothandam Sivakumar

AbstractIsolated subclavian artery is a rare anomaly. A second steal due to a patent arterial duct further reduces arm perfusion. Surgical anastomosis of the isolated vessel to aorta normalises arm perfusion. Simple echocardiographic clues aid in the diagnosis. An associated moderate sized ventricular septal defect was non-surgically closed along with catheter closure of the duct resulting in improved arm perfusion.


2019 ◽  
Vol 29 (06) ◽  
pp. 842-844 ◽  
Author(s):  
Supratim Sen ◽  
Sneha Jain ◽  
Bharat Dalvi

AbstractWe describe two cases of spontaneous embolisation and successful retrieval of ceramic-coated patent arterial duct devices. In both, the device embolised to the descending aorta in the absence of pulmonary hypertension and despite optimum placement. We have discussed possible mechanisms for embolisation in these patients and suggested alternative methods for device retrieval. Based on this limited experience, we conclude that for tubular ducts, ceramic-coated devices should be oversized to form a tighter waist or alternate devices may be considered.


Sign in / Sign up

Export Citation Format

Share Document