A Case of Trigger Finger by Flexor Tendon Sheath Ganglion

2015 ◽  
Vol 16 (2) ◽  
pp. 81-83
Author(s):  
Seok-Kyun Park ◽  
Soo Uk Chae
2001 ◽  
Vol 26 (4) ◽  
pp. 380-383 ◽  
Author(s):  
S. CORDINER-LAWRIE ◽  
J. DIAZ ◽  
P. BURGE ◽  
N. A. ATHANASOU

Trigger finger is due to degeneration and thickening of the proximal portion (A1 pulley) of the flexor tendon sheath, which causes constriction of the flexor tendon. This study reports the presence of localized amyloid deposition in the tendon sheath of 11 of 47 cases (23%) of idiopathic primary trigger finger. Amyloid deposits were only found in patients aged over 46 years old and were present around cells and at sites of mucinous and fibrinoid degeneration which contained highly sulphated glycosaminoglycans. The pathogenic significance of these deposits is uncertain but their small size and presence only in middle-aged and elderly adults suggests that they represent a form of age-associated amyloid deposition.


2016 ◽  
Vol 10 (1) ◽  
pp. 36-40 ◽  
Author(s):  
Junko Sato ◽  
Yoshinori Ishii ◽  
Hideo Noguchi

Objective: This study aims to compare the morphology of the A1 pulley and flexor tendons in idiopathic trigger finger of digits other than the thumb between in neutral position and in the position with the interphalangeal joints full flexed and with the metacarpophalangeal (MP) joint 0° extended (hook grip position). Method: A total of 48 affected digits and 48 contralateral normal digits from 48 patients who initially diagnosed with idiopathic trigger finger were studied sonographically. Sonographic analysis was focused on the A1 pulley and flexor tendons at the level of the MP joint in the transverse plane. We measured the anterior-posterior thickness of A1 pulley and the sum of the flexor digitorum superficialis and profundus tendons, and also measured the maximum radialulnar width of the flexor tendon in neutral and hook grip positions, respectively. Each measurement was compared between in neutral and in hook grip positions, and also between the affected and contralateral normal digits in each position. Results: In all the digits, the anterior-posterior thickness of flexor tendons significantly increased in hook grip position as compared with in neutral position, whereas radial-ulnar width significantly decreased. Both the A1 pulley and flexor tendons were thicker in the affected digits as compared with contralateral normal digits. Conclusion: The thickness of flexor tendons was significantly increased anteroposteriorly in hook grip position as compared with in neutral position. In trigger finger, A1 pulley and flexor tendon were thickened, and mismatch between the volume of the flexor tendon sheath and the tendons, especially in anterior-posterior direction, might be a cause of repetitive triggering.


2019 ◽  
Vol 88 (6) ◽  
pp. 320-326 ◽  
Author(s):  
Z. Joostens ◽  
L. Vanslambrouck ◽  
H. De Cock ◽  
T. Mariën

A six-year-old warmblood horse was presented with a longstanding frontlimb lameness with mild digital flexor tenosynovitis and swelling of the distomedial pastern. Ultrasonography and magnetic resonance revealed a dense mass lesion in the distal aspect of the digital flexor tendon sheath, with a partial lamellar architecture, absence of internal vascularization and adjacent smooth pressure osteolysis of the middle phalanx. After surgical excision, histopathology confirmed an epithelial inclusion cyst. Epithelial inclusion cysts, also known as keratinizing or follicular cysts, are expansile benign mass-like lesions of aberrant epidermal tissue. In the horse, they are known to occur in cutaneous and several non-cutaneous tissues. In the digital flexor tendon sheath, they have rarely been described. Given their often chronic presentation in this location, they may appear as an atypical dense mass on imaging, uncommon for cystic lesions. Complete tenoscopic removal, even for larger masses, is achievable and considered curative with good prognosis for return.


1998 ◽  
Vol 23 (4) ◽  
pp. 490-493 ◽  
Author(s):  
N. S. SARHADI ◽  
J. SHAW-DUNN

Injection studies using methylene blue and latex were used in 60 digits from 40 cadavers to study how anaesthetic fluid injected into the flexor tendon sheath might spread around the proximal part of the finger. The injected solution escaped from the flexor tendon sheath around the vincular vessels which are present near the base and head of the proximal phalanx. Outside the digital canal, the dye flowed smoothly through the perivascular loose areolar tissue and spread alongside the main digital vessels and nerves and their palmar and dorsal branches.


1989 ◽  
Vol 14 (2) ◽  
pp. 244-247
Author(s):  
J. D. GIBEAULT ◽  
P. SABA ◽  
H. HOENECKE ◽  
A. GRAHAM

Two unusual cases of injury to the sesamoids of the M.P. joint of the thumb are described. An anatomical dissection of the M.P. volar plate region, including the sesamoids, was undertaken to delineate the details of the sesamoids’ relationship to the M.P. joint, flexor tendon, flexor tendon sheath and capsule of the joint. Histological studies were carried out to demonstrate a tendinous extension of the muscles that attach to the sesamoids.


Sign in / Sign up

Export Citation Format

Share Document