scholarly journals Surgical Correction of the Sequelae of Obstetric Pubic Symphysis Ruptures

2014 ◽  
Vol 21 (4) ◽  
pp. 15-21
Author(s):  
Ya. G Gudushayri ◽  
A. F Lazarev ◽  
A. V Verzin

Twenty eight patients with old postpartum ruptures of pubic symphysis complicated by functional bladder disorders were operated on during the period from 2000 to 2013. Time interval between vaginal delivery and pelvic ring stabilization made up from 1 month to 8 years. Clinical and roentgenologic examination enabled to detect predisposing factors for neurogenic, i.e. hyperactive bladder development that were treated surgically. In all cases plate osteosynthesis for pubic symphysis and fixation of sacroiliac joint with cannulated screws was performed. Subjective improvement of patients’ condition as well as the results of uroflowmetry and complex urodynamic investigation enabled to conclude that orthopaedic reconstruction of pelvic ring in old obstetric ruptures of pubic symphysis was an effective and reliable technique for the treatment of bladder dysfunction.

Author(s):  
Ya. G. Gudushayri ◽  
A. F. Lazarev ◽  
A. V. Verzin

Twenty eight patients with old postpartum ruptures of pubic symphysis complicated by functional bladder disorders were operated on during the period from 2000 to 2013. Time interval between vaginal delivery and pelvic ring stabilization made up from 1 month to 8 years. Clinical and roentgenologic examination enabled to detect predisposing factors for neurogenic, i.e. hyperactive bladder development that were treated surgically. In all cases plate osteosynthesis for pubic symphysis and fixation of sacroiliac joint with cannulated screws was performed. Subjective improvement of patients’ condition as well as the results of uroflowmetry and complex urodynamic investigation enabled to conclude that orthopaedic reconstruction of pelvic ring in old obstetric ruptures of pubic symphysis was an effective and reliable technique for the treatment of bladder dysfunction.


Author(s):  
Michiel Herteleer ◽  
Mehdi Boudissa ◽  
Alexander Hofmann ◽  
Daniel Wagner ◽  
Pol Maria Rommens

Abstract Introduction In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. In this study, we aim at finding out whether conventional plate osteosynthesis is a valid option in patients with osteoporotic bone. Materials and methods We retrospectively reviewed medical charts and radiographs of all patients with a FFP, who underwent a plate osteosynthesis of the anterior pelvic ring between 2009 and 2019. Patient demographics, fracture characteristics, properties of the osteosynthesis, complications and revision surgeries were documented. Single plate osteosynthesis (SPO) at the pelvic brim was compared with double plate osteosynthesis (DPO) with one plate at the pelvic brim and one plate anteriorly. We hypothesized that the number and severity of screw loosening (SL) or plate breakage in DPO are lower than in SPO. Results 48 patients with a mean age of 76.8 years were reviewed. In 37 cases, SPO was performed, in 11 cases DPO. Eight out of 11 DPO were performed in patients with FFP type III or FFP type IV. We performed significantly more DPO when the instability was located at the level of the pubic symphysis (p = 0.025). More patients with a chronic FFP (surgery more than one month after diagnosis) were treated with DPO (p = 0.07). Infra-acetabular screws were more often inserted in DPO (p = 0.056). Screw loosening (SL) was seen in the superior plate in 45% of patients. There was no SL in the anterior plate. There was SL in 19 of 37 patients with SPO and in 3 of 11 patients with DPO (p = 0.16). SL was localized near to the pubic symphysis in 19 of 22 patients after SPO and in all three patients after DPO. There was no SL in DPO within the first month postoperatively. We performed revision osteosynthesis in six patients (6/48), all belonged to the SPO group (6/37). The presence of a bone defect, unilateral or bilateral anterior pelvic ring fracture, post-operative weight-bearing restrictions, osteosynthesis of the posterior pelvic ring, and the presence of infra- or supra-acetabular screws did not significantly influence screw loosening in SPO or DPO. Conclusion There is a high rate of SL in plate fixation of the anterior pelvic ring in FFP. In the vast majority, SL is located near to the pubic symphysis. DPO is associated with a lower rate of SL, less severe SL and a later onset of SL. Revision surgery is less likely in DPO. In FFP, we recommend DPO instead of SPO for fixation of fractures of the anterior pelvic ring, which are located in or near to the pubic symphysis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Martin C. Jordan ◽  
Veronika Jäckle ◽  
Sebastian Scheidt ◽  
Fabian Gilbert ◽  
Stefanie Hölscher-Doht ◽  
...  

AbstractOperative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.


2021 ◽  
Author(s):  
Martin C. Jordan ◽  
Veronika Jaeckle ◽  
Sebastian Scheidt ◽  
Fabian Gilbert ◽  
Stefanie Hoelscher-Doht ◽  
...  

Abstract Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.


2021 ◽  
Author(s):  
Sheng Zhang ◽  
Huagui Mo ◽  
Yucheng Liu ◽  
Guohua Zhu ◽  
Bin Yu

Abstract Background: This study aimed to share our experience of anterior ring fixation failure for unstable pelvic fractures and propose corresponding treatment strategies. Materials: From January 2009 to December 2018, 93 patients with pelvic fractures were retrospectively reviewed. Patients with failure of the anterior ring internal fixation within 3 months after initial surgery were analyzed. Quality of reduction was evaluated using the Majeed scoring system.Results: According to the Tile classification of fracture, there were 23 cases of type B1, 17 cases of type B2, 11 cases of type B3, 28 cases of type C1, 6 cases of type C2, and 8 cases of type C3. The duration from injury to pelvic internal fixation ranged from 5-28 days. Seven out of 93 patients experienced failure of internal fixation of the anterior pelvic ring within 3 months, including 2 patients fixed with an external fixator and 5 patients were fixed with a plate. Five patients undergoing revision surgery were followed up for 6-36 months with an average of 18 months. According to Majeedscore at the last follow-up, there were 2 cases of excellent, 2 cases of good, 1 case of fair, and the excellent and good rate reached 80%.Conclusion: The treatment of complicated unstable pelvic fractures requires early multidisciplinary cooperation, proper management of hemodynamic stability and other comorbidities, and performing internal fixation surgery within 2 weeks. It is necessary to make a preoperative plan and stabilize the posterior ring first, avoiding a single steel plate crossing the pubic symphysis.


2015 ◽  
Vol 5 (1) ◽  
pp. e6 ◽  
Author(s):  
Alan T. Blank ◽  
Mark Gage ◽  
Nirmal Tejwani ◽  
Toni McLaurin

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Jianyin Lei ◽  
Yue Zhang ◽  
Guiying Wu ◽  
Zhihua Wang ◽  
Xianhua Cai

This study aims to evaluate the biomechanical mechanism of pelvic ring injury for the stability of pelvis using the finite element (FE) method. Complex pelvic fracture (i.e., anterior column with posterior hemitransverse lesion) combined with pelvic ramus fracture was used to evaluate the biomechanics stability of the pelvis. Three FE fracture models (i.e., Dynamic Anterior Plate-Screw System for Quadrilateral Area (DAPSQ) for complex pelvic fracture with intact pubic ramus, DAPSQ for complex pelvic fracture with pubic ramus fracture, and DAPSQ for complex pelvic fracture with fixed pubic ramus fracture) were established to explore the biomechanics stability of the pelvis. The pubic ramus fracture leads to an unsymmetrical situation and an unstable situation of the pelvis. The fixed pubic ramus fracture did well in reducing the stress levels of the pelvic bone and fixation system, as well as displacement difference in the pubic symphysis, and it could change the unstable situation back to a certain extent. The pelvic ring integrity was the prerequisite of the pelvic stability and should be in a stable condition when the complex fracture is treated.


2004 ◽  
Vol 35 (4) ◽  
pp. 445-449 ◽  
Author(s):  
Laura S. Phieffer ◽  
William P. Lundberg ◽  
David C. Templeman

Sign in / Sign up

Export Citation Format

Share Document