scholarly journals 4D-CT-based motion correction of PET images using 3D iterative deconvolution

Oncotarget ◽  
2019 ◽  
Vol 10 (31) ◽  
pp. 2987-2995 ◽  
Author(s):  
Lena Thomas ◽  
Thomas Schultz ◽  
Vesna Prokic ◽  
Matthias Guckenberger ◽  
Stephanie Tanadini-Lang ◽  
...  
Author(s):  
Jussi Schultz ◽  
Reetta Siekkinen ◽  
Mojtaba Jafari Tadi ◽  
Mika Teräs ◽  
Riku Klén ◽  
...  

Abstract Background Dual-gating reduces respiratory and cardiac motion effects but increases noise. With motion correction, motion is minimized and image quality preserved. We applied motion correction to create end-diastolic respiratory motion corrected images from dual-gated images. Methods [18F]-fluorodeoxyglucose ([18F]-FDG) PET images of 13 subjects were reconstructed with 4 methods: non-gated, dual-gated, motion corrected, and motion corrected with 4D-CT (MoCo-4D). Image quality was evaluated using standardized uptake values, contrast ratio, signal-to-noise ratio, coefficient of variation, and contrast-to-noise ratio. Motion minimization was evaluated using myocardial wall thickness. Results MoCo-4D showed improvement for contrast ratio (2.83 vs 2.76), signal-to-noise ratio (27.5 vs 20.3) and contrast-to-noise ratio (14.5 vs 11.1) compared to dual-gating. The uptake difference between MoCo-4D and non-gated images was non-significant (P > .05) for the myocardium (2.06 vs 2.15 g/mL), but significant (P < .05) for the blood pool (.80 vs .86 g/mL). Non-gated images had the lowest coefficient of variation (27.3%), with significant increase for all other methods (31.6-32.5%). MoCo-4D showed smallest myocardial wall thickness (16.6 mm) with significant decrease compared to non-gated images (20.9 mm). Conclusions End-diastolic respiratory motion correction and 4D-CT resulted in improved motion minimization and image quality over standard dual-gating.


2005 ◽  
Vol 25 (1_suppl) ◽  
pp. S622-S622
Author(s):  
Hans R Herzog ◽  
Lutz Tellmann ◽  
Roger Fulton ◽  
Isabelle Stangier ◽  
Elena Rota Kops ◽  
...  
Keyword(s):  

Author(s):  
M Baier ◽  
M Ullrich ◽  
J Dinkel ◽  
F Schoenahl ◽  
U Lützen ◽  
...  
Keyword(s):  
4D Ct ◽  

2005 ◽  
Vol 44 (S 01) ◽  
pp. S46-S50 ◽  
Author(s):  
M. Dawood ◽  
N. Lang ◽  
F. Büther ◽  
M. Schäfers ◽  
O. Schober ◽  
...  

Summary:Motion in PET/CT leads to artifacts in the reconstructed PET images due to the different acquisition times of positron emission tomography and computed tomography. The effect of motion on cardiac PET/CT images is evaluated in this study and a novel approach for motion correction based on optical flow methods is outlined. The Lukas-Kanade optical flow algorithm is used to calculate the motion vector field on both simulated phantom data as well as measured human PET data. The motion of the myocardium is corrected by non-linear registration techniques and results are compared to uncorrected images.


Author(s):  
J Scheins ◽  
CR Brambilla ◽  
J Mauler ◽  
E Rota kops ◽  
L Tellmann ◽  
...  
Keyword(s):  

Author(s):  
K Mathias ◽  
A Block ◽  
O Waletzko ◽  
C Vockelmann ◽  
R Rohn
Keyword(s):  